cador evaluado que genera un valor Vind. Pi es un factor de forma que define si la curva es cóncava, convexa, recta o con forma de “S”. Ci establece, en curvas con Pi>1, el valor de la abscisa en el que se produce el punto de inflexión. Ki define el valor de la ordenada del punto Ci. B es el factor para que la función se mantenga en el rango de 0 a 1 y está definido por la ecuación 3.

In equation 2, A is the response value Xmax (indicator’s abscissa), and Xalt is the assessed indicator abscissa which generates a value Vind. Pi is a shape factor that defines if the curve is concave, convex or shaped as a “S”. Ci establishes, in curves with Pi >1, abscissa’s value for the inflexion point. Ki defines the response value to Ci. B is the value that

[3]

Los valores de los 5 parámetros de cada indicador se muestran en la Tabla 2. De las 17 funciones de valor, 8 son convexas decrecientes (CvxD), 5 son lineales decrecientes (SD) y 4 son cóncavas decrecientes (CcvD). Las convexas son para los indicadores en los cuáles una satisfacción parcial ya es suficiente para la administración, como: los plazos de construcción, los indicadores medioambientales... En cambio las cóncavas son para aquellos en los cuáles la administración exige una valoración máxima, por ejemplo la seguridad. En las funciones decrecientes se ha tomado como valoración más satisfactoria el valor cero y menos satisfactorio el valor más deficiente de los sistemas estudiados.

Tabla 2. Parámetros de la función de valor de cada indicador. Parameters of each indicator value function ARCHITECTURE AND CRISIS

keeps the function in the range from 0 to 1 and it is defined in equation 3. These 5 parameters values for each indicator are shown in Table 2. From the 17 value functions, 8 decrease convexly (CvxD), 5 decrease lineally (SD) and 4 decrease concavely (CcvD). Convex functions are for indicators which the administration accepts a partial satisfaction, such as: construction timeframes, environmental indicators… On the other hand, concave functions represent indicators which the administration demands a maximum value, such as safety. Decreasing functions have 0 as the most sa-

Ix

Unidad/ Unit

X max.

X min.

C

K

P

Forma/ Shape

I1

(€/m²)

1800

0

300

1

1

CvxD

I2

(%)

20

0

20

0.01

1

SD

I3

(€/m²)

800

0

800

0.01

1

SD

I4

(meses/ months)

20

0

5

1

1

CvxD

I5

(meses/ months)

4

0

1,5

1

1

CvxD

I6

(m³/m²)

30.000

0

9000

1

1

CvxD

I7

(kgCO2/m²)

750

0

250

1

1

CvxD

I8

(MJ/m²)

7000

0

2000

1

1

CvxD

I9

(kgCO2/m²)

33

0

12

1

1

CvxD

I10

(kgCO2/m²)

45

0

45

0.01

3

CcvD

I11

(kg/m²)

130

0

130

0.01

3

CcvD

I12

(kgCO2/m²)

800

0

150

1

1

CvxD

I13

(kg/m²)

1500

0

1500

0.01

1

SD

I14

(%)

100

0

100

0.01

1

SD

I15

(%)

100

0

100

0.01

1

SD

I16

(puntos/ points)

250

0

250

0.01

3

CcvD

I17

(puntos/ points)

1000

0

1000

0.01

3

CcvD 173