NAFS SHIPPING MAGAZINE - BWTS

PANASIA, GloEn-Patrol: A technical combination of filtration and ultra violet disinfection BPCO LTD represents exclusively PANASIA Co.

Ballast Water Management System of PANASIA, GloEn-Patrol, is a technical combination of filtration and ultra violet disinfection. PANASIA owns all technologies for filter and ultra violet disinfection unit achieving strong points in fastest feedback on technology issues and spare parts cost control. As a frontier in BWMS field, PANASIA has achieved contracts of 998 equipment of which 749 was provided. Followings are brief explanations about advantages of PANASIA GloEn-Patrol. 1. Physical treatment type : UV is physical treatment type that is free from corrosion concerns and safety concerns. And GloEn-Patrol doesn’t require chemical storage inside vessel. 2. No depedence on water salinity & temperature : performance and power consumption of electrolysis type BWTS varies greatly depending on sea water salinity & temperature. Especially in fresh water, the type must be equipped with brine take that requires more space & regular brine supply. 3. Lowest maintenance cost : GloEn-Patrol innovatively reduces maintenance cost by increasing UV lamp life time up to 4,000 hours and reducing regular maintenance points. 4. TSS (Total Suspended Solid) : This aims to see the weight(mg) of particles in water (per lilter) by evaporating sample water to leave particles inside. This criterion has been utilized to estimate the performance of UV light because particles in water can reflect or absorb UV light disturbing its penetration. IMO CONVENTION 2004 & ETV Protocol for USCG simultaneously chose TSS as one of main criterion of water quality. Both set the standard of TSS as 50mg/L but our system was tested around 650mg/L condition at maximum and ICS declared at BWT Technical Cooperation 2015 at Busan on 3~4 Nov, 2015 “system must be operated under 600+ TSS value. 5. Explosion Proof Certified : GloEn-Patrol is certified its explosion proof function by DNV ATEX & DNV IEC-Ex. 6. Automatic Power Control : GloEn-Patrol controls its power consumption in three kinds of levels to save as much power as possible by detecting UV intensity.

40 NAFS NOVEMBER 2016

7. MP(Medium Pressure) UV application : Comparing to Low Pressure UV lamp that emits short wavelength, MPUV can emits various wavelengths in which large types of organisms are subject to elimination. 8. PANASIA has carried out USCG Type Approval Tests under FDA/CMFDA biological testing method and will achieve the Type Approval by early of 2017. 9. Smallest amount of water loss in back flushing : Comparing to competitors, GloEn-Filter’s amount of water loss for Back-Flushing is 130 times smaller at maximum. Large water loss contributes to total cargo unloading time extension. 10. Revised G8 Guidelines are applicable with the existing BWMS model.

OVERVIEW NO SHIP’S TYPE

CONTRACTED

DELIVERED

1

TANKER (EXPLOSION PROOF TYPE)

194

151

2

BULK CARRIERS

192

166

3

CONTAINER

186

162

4

GENERAL CARGO SHIP & MULTI PURPOSE CARRIER

63

60

5

RO-RO SHIP

24

24

6

OFFSHORE & SUPPORT 60 VESSEL

55

7

DRILLSHIP

15

15

8

LNG/LPG CARRIER

87

70

9

SPECIAL SHIP

24

22

10

RETROFIT

141

20

986 Ships

745 Ships

TOTAL