FINISHES LEGEND TAG BC BF BG CT1
DP FEN FT1 FT4 MC2
FINISHES LEGEND
DESCRIPTION
TAG PILE
DENOTES SELECTED CEDAR CLADDING.155X18mm HORIZONTAL URBANLINE EUROCLAD. COLOR TBC. BRICK FACE FINISH BOX GUTTER CEILING TYPE 1. TYPICALLY 10MM PLASTERBOARD CEILING LININGS ON "RONDO" (OR SIMILAR APPROVED) 25MM METAL CEILING BATTENS FIXED 450MM CTRS. MAX. TO UNDERSIDE OF FLOOR TRUSSES/JOISTS, TIMBER RAFTERS & TRIMMERS AS PER MANUFACTURER'S DETAILS & SPECIFICATIONS. ALLOW TO PROVIDE 10MM W.R. PLASTERBOARD CEILING LININGS WET AREAS. ALLOW FOR 'PERFECT ANGLE' SQUARE SET PLASTER STOPPING JOINTS TO ALL INTERNAL CEILING AREAS. DOWN PIPE FENCE. FLOOR TYPE 1. CONCRETE SLAB TO STRUCTURAL ENGINEERS DRAWINGS. FLOOR TYPE 4. TIMBER DECKING ON TIMBER POST. METAL CLADDING TYPE 2. COLORBOND FLAT METAL CLADDING ON MARINE PLY SUBSTRATE.
RF RT1
RWH TF02 TMD WT1 WT2
WT4
MF01
SCHEDULE OF FINISHES
DESCRIPTION DENOTES TYPICALLY 450Ø CONCRETE PILE FOOTINGS AS PER STRUCTURAL ENGINEER'S DRAWING DETAILS & SPECIFICATIONS. RENDER FINISH ROOFING TYPE 1. SELECTED 0.48mm BMT COLORBOND STEEL KLIPͲLOK' ROOF SHEETING FIXED TO ROOF BATTENS TO SUIT @ 900mm CTRS. MAX. ON RAFTERS AS PER MANUFACTURER & STRUCTURAL ENGINEER'S DESIGN DETAILS & SPECIFICATIONS. ALLOW FOR SARKING & INSULATION AS PER ENERGY RATERS REPORT & TO BE INSTALLED AS PER MANUFACTURER'S DETAILS & SPECIFICATIONS. RAIN WATER HEAD. COLOURBOND . COLOUR TBC
WALL FINISHES: RF Ͳ DENOTES SELECTED APPLIED RENDERED FINISH TO 75MM UNITETEX UNIͲBASE NONͲ CAVITY SYSTEM TO MANUFACTURERS DETAILS AND SPECIFICATION FB Ͳ DENOTES SELECTED RECYCLED BRICK VENEER BC Ͳ DENOTES SELECTED CEDAR HORIZONTAL FINISH IN CLEAR STAINED FINISH MC Ͳ DENOTES BLACK PAINT OR BLACK ANODIZED FINISH TM Ͳ DENOTES SELECTED TIMBER BOARD AND BATTER CLADDING IN CHARCOAL STAIN FINISH RFB Ͳ RENDERED BRICK WORK FLOOR/CEILING FINISHES: TB.01 Ͳ DENOTES SELECTED TIMBER FLOOR BOARDS. CON Ͳ DENOTES CONCRETE FINISH. FT.01 Ͳ DENOTES SELECTED FLOOR TILES TV.01 Ͳ DENOTES SELECTED TIMBER VENEER PB.01 Ͳ DENOTES PLASTER BOARD CP.01 Ͳ DENOTES SELECTED CARPET FINISH GARAGE DOORS: SELECTED TIMBER STYLE FINISH SECTIONAL PANELͲLIFT GARAGE DOORS.
WALL TYPE 1. 240mm THICK LOAD BEARING EXTERNAL MASONRY VENEER. WALL TYPE 2. 190mm REINFORCED CONCRETE BLOCK RETAINING WALLS AS PER STRUCTURAL ENGINEERS DETAILS & SPECIFICATIONS. WALL TYPE 4. 90mm THICK NON LOAD BEARING & LOAD BEARING INTERNAL & EXTERNAL TIMBER STUD.
GUTTERS, DOWNPIPES FLASHINGS & THE LIKE: SELECTED "COLORBOND" TYPE. ROOFS: SELECTED 0.48 BMT KLIPLOK 402 SHEETING TO BE INSTALLED AS PER MANUFACTURERS SPECIFICATION WINDOW: SELECTED POWDER COATED ALUMINUM TYPE.
ROOF LEGEND DP SP S SO RH
Ͳ DENOTES 'COLORBOND' DOWN PIPES. Ͳ DENOTES ' COLORBOND' SPREADER DOWN PIPES. Ͳ DENOTES SUMP PIT. Ͳ DENOTES SUMP PIT AND OVER FLOW Ͳ DENOTES CUSTOM FOLDED 'COLORBOND' RAIN HEAD. Ͳ DENOTES DIRECTION OF FALL OF BOX GUTTER TO DOWN PIPE. NOTE: ALLOW FOR ALL BOX GUTTERS, PARAPET AND GENERAL ROOFING CAPPING'S, FLASHING'S AS REQUIRED THROUGHOUT, (TO BE CONSTRUCTED 0.48mm BMT SELECTED KLIPLOK SHEETING).
1 WD005
PROPOSED UNIT 2
?
610
PROPOSED UNIT 3
BG
RT1
MC2
RF
2W13 2FF
CL
CL
TF02
RF BC
TMD
MASTER BED
BATH
310 DEEP PRYDA FLOOR TRUSSES AT 450 CTS. REFER TO ENGINEER'S SPECIFICATION AND MANUFACTURER'S INSTALLATION GUIDE LINES.
310 DEEP PRYDA FLOOR TRUSSES AT 450 CTS. REFER TO ENGINEER'S SPECIFICATION AND MANUFACTURER'S INSTALLATION GUIDE LINES.
2D09 2FF
2D11 2FF
2D12 2FF
2D13 2FF
2W10 2FF
2700
2700
3W07 3FF
WT1
MC2
UNIT 2 FIRST FLOOR FFL 83.25
MF01
3W09 3FF
RWH
BF
BF
350
350
MC2
CL
FEN CT1
DP
3W01 3GF BF
2700
2D02 2GF
2D14 2GF
WT1
RT1
2D06 2GF
2700
UNIT 3 GARAGE
WT1
2D01 2GF
2D03 2GF
WT2 FT4
WT2
WT4
3D03 3GF
UNIT 2 GROUND FLOOR 80.200
FT4
APPLY CONTINOUS TERMITE TREATMENT TO PERIMETER OF SLABS AND SLAB PENETRATIONS IN COMPLIANCE WITH AS3660.1 AND PART 3.1.3 OF THE NCC
PILE
PILE
PILE
RAFT FOOTINGS AS PER ENGINEER'S DESIGN AND SPECIFICATION.
PILE
PILE
FT1 WT2
PILE
850
850
FT4
RAFT FOOTINGS AS PER ENGINEER'S DESIGN AND SPECIFICATION. APPLY CONTINOUS TERMITE TREATMENT TO PERIMETER OF SLABS AND SLAB PENETRATIONS IN COMPLIANCE WITH AS3660.1 AND PART 3.1.3 OF THE NCC
Section 3 1 : 50
NOTES: CONTRACTOR MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING WORK OR PREPARING SHOP DRAWINGS. DO NOT SCALE DRAWING
Ͳ CEILINGS (UNIT 1,2&3): R5.0 BULK INSULATION IN THE CEILING AND SARKING TO THE ROOF EXCLUDING THE GARAGE. Ͳ FLOORS (UNIT 1&2): NO INSULATION REQUIRED. Ͳ FLOORS (UNIT 3): (RATING HAS BEEN CONDUCTED WITH RATING R1.0 BEING ADDED TO A RAFT SLAB. IF THIS IS NOT THE CASE, A REͲRATING WILL NEED TO OCCUR) Ͳ WALLS (UNIT 1): R2.5 BULK INSULATION WITH 1 LAYER OF BREATHABLE MEMBRANE WRAP TO ALL THE EXTERNAL WALLS EXCLUDING THE GARAGE. R2.5 BULK INSULATION IN THE INTERNAL GARAGE AND BATHROOM WALLS AND EACH SIDE OF THE PARTY WALLS ADJOINING UNIT 2. Ͳ WALLS (UNIT 2): R2.5 BULK INSULATION WITH 1 LAYER OF BREATHABLE MEMBRANE WRAP TO ALL THE EXTERNAL WALLS EXCLUDING THE GARAGE. R2.5 BULK INSULATION IN THE INTERNAL GARAGE AND BATHROOM WALLS AND EACH SIDE OF THE PARTY WALLS ADJOINING UNIT 1. Ͳ WALLS (UNIT 3): R2.5 BULK INSULATION WITH 1 LAYER OF BREATHABLE MEMBRANE WRAP TO ALL THE EXTERNAL WALLS EXCLUDING THE GARAGE. R2.5 BULK INSULATION IN THE INTERNAL GARAGE AND BATHROOM WALLS.