Universal Joints Installation Running Conditions

Fig 1

Correct forks in line A & B equal

Intermittent* Running Conditions

Speed Angle of Operation - Degrees rpm 0 3 5 7 10 15 20 25 30 1800 1500 1200 900 600 300 100

9 8 7 6 5 4 3

20 16 13 11 8 5 4

34 28 22 16 11 7 4

45 39 32 23 15 8 5

- - - - - - - - 40 - - - 34 - - - 22 34 40 - 11 16 22 28 34 6 8 9 11 12

Fig 2

* Running under load for less than 15mins. ** Running under load from 15mins to 8hrs.

Continuous** Running Conditions

Speed Angle of Operation - Degrees rpm 0 3 5 7 10 15 20 25 30 1800 1500 1200 900 600 300 100

254

18 16 14 12 10 8 6

40 32 26 21 15 10 7

68 55 44 32 22 14 8

90 78 64 46 30 16 10

- - - - - - - - 80 - - - 68 - - - 44 68 80 - 22 32 44 55 68 12 15 18 22 24

Incorrect forks out of line

incorrect angles A & B unequal

Multiply design torque by correction factor from the tables, resulting number must be lower than the static breaking torque of the joint.

To order or obtain price and availability phone (+44) 0 170 728 3131