SERIES W50 TECHNICAL CATALOGUE
Curtain Wall system for facades and roofs Heat-insulated building construction Series W 50
1
Catalogue cover
64
T-connection
3
Catalogue pages – Overview
65
T-connection
4
Design Description
66
T-connection
5
System Description
67
Reinforcement
6
Installation Depths/Levels/Drainage Facilities
68
Variable T-connection Variable T-connection
W50
3
7
Statics Table
69
8
Statics Table
70
Variable T-connection
9
Statics Table
71
Accessories
10
Statics Table
72
Accessories
11
Statics Table
73
Accessories
12
Dimensioning of Mullions and Transoms
74
Screws
13
Predimensioning Table
75
T-connection
14
Statics Predimensioning, Spar Spacing 80 cm
76
Cutting Points
15
Statics Predimensioning, Spar Spacing 90 cm
77
Drilling template
16
Statics Predimensioning, Spar Spacing 100 cm
78
Drilling template
17
Statics Predimensioning, Spar Spacing 110 cm
79
T-connection transom
18
Statics Predimensioning, Spar Spacing 120 cm
80
Cutting point, horizontal
19
Calculation of the Thermal Conductivity Coefficient Ucw
81
Installation of insulator PK 426 in sash area
20
Nominal Values of Thermal Conductivity Coefficient Uf
82
Cut lengths
21
Profiles
83
Facade connections
22
Profiles
84
Cutting point
23
Profiles
85
Cutting point
24
Profiles
86
Cutting point
25
Profiles
87
Cutting point
26
Profiles
88
Cutting point
27
Profiles
89
Cutting point
28
Profiles
90
Cutting point
29
Profiles
91
Cutting point
30
Profiles
92
Cutting point
31
Profiles
93
Cutting point
32
Profiles
94
Cutting point
33
Profiles
95
Cutting point
34
Profiles
96
Section of A turning mode (45o angle)
35
Profiles, pressure and cover profiles
97
Section of A turning mode (60o angle)
36
Frame Inserts
98
Cutting point, horizontal, below or above the window sash
37
Frame Inserts
99
Cutting point
38
Frame Inserts
100
Cutting point
39
Window Inserts
101
Cutting point
40
Auxiliary and connecting profiles
102
Cutting point
41
Variable angle profiles
103
Cutting point
42
Accessories
104
Cutting point
43
Accessories
105
Cutting point
44
Accessories
106
Cutting point
45
Accessories
107
Cutting point
46
Corner connectors
108
Cutting point
47
Corner connectors
109
Cutting point
48
Corner connectors
110
Cutting point
49
T-connection
50
T-connection
51
T-connection
52
T-connection
53
T-connection
54
T-connection
55
T-connection
56
T-connection
57
T-connection
58
T-connection
59
T-connection
60
T-connection
61
T-connection
62
T-connection
63
T-connection
www.balkan.gr
4
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Design Description
Light alloy profile system for facades
Facade:
Thermal-insulated facade mullion-and-transom construction with disengaged transom profiles for optimum load transmission. The heat insulation, formed from the insulator profile, is integrated into the supporting inner profile over its full length by means of a special groove. Uf values to EN ISO 10077. Dimension values Uf,BW to DIN V 4108-4: 2002 The glazing or the installation of insert elements such as e.g. windows or doors is made with pressure profiles screwed on from the outside. With a corresponding mullion formation (half mullions), the facade can be fitted with the W50 concealed window sash. Cover profiles in various heights and forms are available for covering the pressure profiles.
Dimensions*: Statics:
Mullion and transom profiles with 50 mm visible width. Installation depths available in graduated dimensions according to statics requirements from 80 mm to 200 mm. The design conforms in its statics to DIN 4113, DIN 1005 and unconditionally to the technical guidelines of the glass industry.
* The installation depths indicated in the catalogue are reference dimensions for planning. The manufactured dimensions for frame and sash profiles lie 0.4 mm above the nominal dimensions in the catalogue, the glazing bar profiles 0.2 mm
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Design Description
W50
5
System Description
1. 2.
3.
4.
5.
6.
7. 8.
The visible width of the facade profiles is 50 mm.
The installation depths of the mullion and transom profiles are designed in graduated dimensions according to statics requirements from 80 mm to 200 mm. Half mullions and half transoms to receive D, DK and tilting sashes while maintaining the‌mm outside visible width in the window area by concealed, integrated ashes.
Room-side hollow chambers for installation of special push-in profiles for securing and connection of the mullion profiles.
Facade mullion-and-transom constructions with disengaged mullion profiles for transom connection and hence for optimum load transmission. Sash available with clamped and bpnded glazing.
The glazing or the installation of insert elements such as e.g. windows or doors is made with pressure profiles screwed on from the outside. Glazings and panels with thicknesses from 24 to 38 mm can be installed using spacers and/or gasket profiles. The use of integrated window profiles in conjunction with half mullion or half transom profiles is possible.
The dry glazing is performed from inside and outside with EPDM gaskets. Ventilation of the glazing rabbet from the outside is effected via special ventilation channels.
Draining is effected under control via drainage levels or the mullion or transom profiles.
All connecting and retaining parts of the facade construction are made from aluminium or stainless steel.
www.balkan.gr
9.
10.
11. 12.
13. 14.
15.
16. 17.
The pressure profiles are screwed on through the insulator into preformed screw channels of the mullion and transom profiles with a maximum spacing of 25 cm.
The pressure profiles are covered uding cover profiles in various heights and forms from 12 to 30 mm. The vertical cover profiles should stand higher than the horizontal cover profiles.
All profiles can be anodised or painted.
The heat insulation, formed from the insulator profile, is integrated into the supporting inner profile over its full length by means of a special groove. The Uf values were determined in accordance with DIN EN ISO 10077-2. Dimensioning values Uf, BW to DIN V 4108-4: 2002.
The outer cover profiles at the facade junction points have a visible width corresponding to the viewing angles.
The aluminium profiles extruded dimensionally to DIN EN 12020 are made of the alloy DIN 6060 (AIMgSi 0.5 F-22) in anodised quality.
The design conforms in its statics to DIN 4113, DIN 1005 and unconditionally to the technical guidelines of the glass industry.
All loads occurring must be reliably transmitted to the building.
The “Code of Practice for the Processor� in our latest main catalogue must be observed for the use and processing of our design.
6
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Installation Depths/Levels/Drainage
W50
Installation Depths/Levels/Drainage
Mullion Level 3
Transom Level 1
Transom Level 2
shown in reduced size
Drawn rotated through 90o
Mullion, Vertical Level 3
Transom, Vertical Level 1
Transom, Horizontal Level 2
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Table
W50
7
Statics Table, Profile Series W50 Mullion Level 3, Vertical
www.balkan.gr
Profile No.:
Ix cm4
min Wx cm3
ex cm2
Iy cm4
min Wy cm3
ey cm2
AH550-5114080 W51 14080
62.76
14,14
4,26
22,16
8,86
2,50
AH550-5114100 W51 14100
107,53
19,39
5,15
26.35
10,54
2,50
AH550-5114120 W51 14120
167,14
25,20
6,06
30,53
12,21
2,50
AH550-5114140 W51 14140
243,04
31,53
6,99
34,71
13,88
2,50
AH550-5114160 W51 14160
352,81
40,72
8,03
43,47
17,39
2,50
AH550-5114180 W51 14180
553,02
58,90
9,31
56,17
22,47
2,50
AH550-5114200 W51 14200
790,30
74,78
10,13
66,36
26,54
2,50
AH550-5115080 W51 15080
39,89
8,17
3,81
5,25
2,41
1,30
AH550-5115120 W51 15120
111,40
15,30
5,42
6,24
2,72
1,19
AH550-5115160 W51 15160
249,00
26,50
7,30
7,35
3,08
1,09
AH550-5113080 W51 13080
83,60
17,85
4,01
83,60
17,85
4,01
8
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Table
Statics Table, Profile Series W50 Transom Level 2, Horizontal
Ix cm4
min Wx cm3
ex cm2
Iy cm4
min Wy cm3
ey cm2
0,61
0,49
0,54
4,46
1,78
2,50
2,85
1,60
1,27
8,70
3,48
2,50
9,09
3,90
2,21
11,84
4,73
2,50
20,07
6,43
2,92
14,84
5,99
2,50
50,74
11,12
3,99
20,20
8,08
2,50
101,07
18,97
5,22
25,22
10,09
2,50
157,44
24,63
6,16
29.41
11.76
2.50
229,37
30,82
7,10
33.59
13.43
2.50
334,15
39,76
8,14
42.38
16.95
2.50
Ix cm4
min Wx cm3
ex cm2
Iy cm4
min Wy cm3
ey cm2
55,84
13,01
4,11
20,64
8,25
2,50
Profile No.:
Ix cm4
min Wx cm3
ex cm2
Iy cm4
min Wy cm3
ey cm2
AH550-5113001
2,8731
1,545
1,21
9,0602
3,62
2,15
Art Nr.:
AH550-5122011
W51 22011
AH550-5122024
W51 22024
AH550-5122039
W51 22039
AH550-5122054
W51 22054
AH550-5122079
W51 22079
AH550-5122099
W51 22099
AH550-5122119
W51 22119
AH550-5122139
W51 22139
AH550-5122159
W51 22159
Transom Level 1, Vertical
Profile No.:
AH550-5121077
W51 21077
Mullion Adaptor for Variable Angles
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Table
W50
9
Statics Table, Profile Series W50 Transom, Frames, Sashes
Ix cm4
min Wx cm3
ex cm2
Iy cm4
min Wy cm3
ey cm2
41,10
8,53
3,88
5,10
2,35
1,30
13,72
4,65
2,45
5,37
2,14
1,69
26,22
5,99
3,62
6,11
2,97
1,44
AH550-5150003
9,18
2,78
2,06
48,8
9
1,23
AH275-280
10,51
3,85
2,15
50,3
9,13
1,29
Ix cm4
min Wx cm3
ex cm2
Iy cm4
min. Wy cm3
ey cm2
33.81
10.50
3.05
20.78
9.19
2.26
68.81
16.09
3.99
26.13
11.56
2.26
120.02
22.56
4.95
31.48
13.93
2.26
189.88
29.88
5.91
36.83
16.30
2.26
280.77
38.04
6.89
42.19
18.66
2.26
AH550-5182180
429.49
51.86
2.22
22.32
10.05
8.28
AH550-5182200
571.37
62.13
2.20
24.17
10.99
9.19
Profile No.:
AH550-5122080
W51 22080
AH550-5150053
W51 50053
AH550-5150080
W51 50080
AH550-5150015
Push-in profiles for mullions
Profile No.:
AH550-5182080
W51 82080
AH550-5182100
W51 82100
AH550-5182120
W51 82120
AH550-5182140
W51 82140
AH550-5182160
W51 82160
www.balkan.gr
10
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Table
Statics Table, Profile Series W50 Pressure plate and cover profiles
Pressure plate and cover profiles
Profile No.:
Dev. anod. [mm]
Dev. elox. [mm]
AH550-5051006 W50 51006
155
50
AH 550-50 57010 W50 57010
182
-
AH550-5061012 W50 61012
147
74
AH550-5061015 W50 61015
159
80
AH550-5061020 W50 61020
177
90
AH550-5067030 W50 67030
248
155
AH550-5063098
293
206
AH550-5113002
256
58
AH550-5113003
218
49
AH550-5113004
354
81
AH550-5113005
104
29
AH550-5113006
83
11
Profile No.:
Dev. anod. [mm]
Dev. elox. [mm]
AH550-9071008 W90 71008
68
53
AH550-9071010 W90 71010
76
45
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Table
W50
11
Statics Table, Profile Series W50 Connectors profiles for structural
Connectors profiles
Glass support
Profile No.:
Dev. anod. [mm
Dev. elox. [mm]
AH550-901
119
-
AH550-902
114
-
AH550-903
97
-
Profile No.:
Dev. anod. [mm
Dev. elox. [mm]
AH550-5184045
215
-
AH550-5184044
214
-
AH550-5184046
217
-
AH550-5184346
216
-
AH550-5182000
974
-
AH550-5184001
192
-
AH550-5184002
98
-
Profile No.:
Dev. anod. [mm
Dev. elox. [mm]
94
-
123
-
AH550-5150001
54
-
AH550-5150002
83
-
AH550-5156042
W51 56042 AH550-5156053
W51 56053
www.balkan.gr
12
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Table
Dimensioning of Mullions and Transoms
Loading width: The loading width c1 or c2 is determined by half the fields adjacent to the mullions or transoms.
Loading width
A freely supported girder on two supports with trapezoidal or triangular load is assumed as the load case. The division of the load-bearing surface is effected by halving the angles.
Support width 1 (cm)
Load case:
Admissible bending: The general rule is fz ul. = q/300 • I (DIN 18056) The insulating glazing manufacturers regard this as the maximum bending between the support points of support spacing I, but limit the admissible bending in the partial area (bending between the supporting points of the largest part-area) to fzul. = 1/300 • I = 0,8 cm.
Load assumptions: (DIN 1055 Part 4) Dynamic pressure q = 0,5 kN/m2 (height above ground = 0-8 m) Dynamic pressure q = 0,8 kN/m2 (height above ground = 8-20 m) Dynamic pressure q = 1,1 kN/m2 (height above ground = 20-10m) Pressure coefficient cp = 0,8 + 1/4 = 1,0 Wind pressure w = q • c p (kN/m2) Material strength specifications of the Al alloy AlMgSi 0.5 F22 (DIN 4113) Minimum tensile strength β z = 22 kN/cm2 Minimum yield strength d 0,2 = 16 kN/cm2 Admissible strain (main load H): d zul = 95 N/mm2 Modulus of elasticity E = 7000 kN/cm2
Mullion spacing
Mullion spacing
Application of tables I and II For mullions or transoms of single-pane fields Example “A” use Table I For mullions or transoms of multi-pane fields Example “Β” use Table II if all the part-areas are = 240 cm in size. In Example “C” the largest partial area of the mullion is dimensioned as 320 cm. As this is larger than 240 cm, f zul. = 0,8 cm or fzul. = lp/ 0,8 • I = 320/0,8 • I = 1/400 • I applies for this area. This admissible bending of 1/400 • I of the partial area applies to the whole mullion length of 460cm.
Support width 1 (cm)
Support width 1 (cm) = 460 cm
Transom
Mullion spacing
Mullion spacing
Transom
Mullion spacing
Mullion spacing
Support width 1 (cm) = 460 cm
In order to determine the necessary inertia moment Ix, the value from Table II opposite must first be divided by 300 and then multiplied by 400.
Transom
Mullion spacing
Mullion spacing
April 2009
180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
4,7 5,5 6,5 7,5 8,6 9,9 11,3 13,3 15,6 18,2 21,0 24,2 27,8 31,7 36,1 40,8 46,0 51,7 57,9 64,7 72,0 79,9 88,5 97,7 108 118 130 142 155 169 184 200 217 235 254 274 295 318 341 357 393 421 450
30
3,2 3,8 4,4 5,1 5,9 6,7 7,6 9,0 10,5 12,2 14,2 16,3 18,7 21,3 24,2 27,4 30,9 34,7 38,9 43,4 48,3 53,6 59,3 65,5 72,1 79,2 85,9 95,0 104 113 123 134 145 157 170 183 197 212 228 245 263 281 301
20
50
7,2 8,5 10,1 11,8 13,7 15,7 18,0 21,3 25,0 29,2 33,9 39,2 45,0 51,5 58,6 66,4 75,0 84,4 94,6 106 118 131 145 160 177 194 213 234 255 279 303 330 358 387 419 452 488 525 564 606 650 696 745
60
8,1 10,6 12,7 15,0 17,6 20,4 23,5 27,9 33,0 38,7 45,1 52,3 60,3 69,2 78,9 89,7 102 114 129 144 161 179 198 219 242 267 293 321 351 383 417 454 493 534 578 624 674 726 780 838 900 964 1032
70
8,8 10,6 12,7 15,0 17,6 20,4 23,5 27,9 33,0 38,7 45,1 52,3 60,3 69,2 78,9 89,7 102 114 129 144 161 179 198 219 242 267 293 321 351 383 417 454 493 534 578 624 674 726 780 838 900 964 1032
80
9,2 11,3 13,6 16,2 19,0 22,2 25,6 30,6 36,3 42,7 49,9 58,0 67,0 77,0 88,0 100 114 128 144 162 180 201 223 247 273 301 330 362 397 433 472 514 558 605 655 707 763 822 885 951 1021 1094 1171
90
9,4 11,6 14,1 16,9 20,1 23,5 27,3 32,8 39,1 46,2 54,1 63,0 73,0 84,0 96,3 110 125 141 159 178 199 222 247 273 302 333 366 402 440 481 525 571 620 673 729 788 851 917 987 1061 1139 1221 1308
110
20,9 24,9 29,4 35,7 42,9 51,1 60,4 70,8 82,5 95,5 110 126 143 163 184 207 232 259 289 321 355 393 433 475 521 571 623 679 739 802 869 941 1016 1097 1181 1271 1365 1465 1569 120
29,6 36,3 43,9 52,6 62,4 73,5 85,9 99,8 115 132 151 172 195 219 246 279 308 342 379 419 463 509 558 612 668 729 793 862 935 1012 1094 1181 1273 1370 1472 1580 1694 130
44,2 53,3 63,6 75,3 88,4 103 119 137 157 179 204 230 259 290 324 361 401 444 490 540 593 650 711 776 845 919 997 1080 1169 1262 1361 1465 1576 1692 1814
Load width a [cm]
100
14,3 17,3 20,7 24,5 28,6 34,5 41,3 49,0 57,6 67,3 78,2 90,2 104 118 135 152 172 193 216 241 269 298 330 364 400 440 482 527 575 626 681 739 800 866 935 1008 1086 1168 1254 1345 1440 140
64,0 76,2 89,9 105 122 141 163 186 211 239 270 303 339 378 420 466 515 568 625 685 750 820 894 972 1056 1145 1239 1339 1445 1556 1674 1799 1930 150
90,4 106 124 144 166 190 217 247 279 314 352 393 438 486 538 594 654 718 787 860 939 1022 1111 1205 1305 1411 1524 1643 1768 1900 2040
For mullions or transoms Single-paned fields, use Table I
160
125 145 168 194 221 252 286 322 362 405 452 503 557 616 679 747 820 897 980 1068 1162 1262 1367 1479 1598 1724 1857 1997 2144 170
169 195 224 256 291 329 370 415 464 517 574 636 702 773 849 930 1017 1110 1209 1313 1425 1543 1668 1800 1940 2087 2243 180
225 258 294 333 376 423 474 529 588 652 721 796 875 960 1051 1148 1251 1361 1477 1601 1732 1871 2017 2172 2336 190
295 335 380 428 481 538 599 666 737 814 897 985 1080 1181 1288 1403 1525 1654 1791 1936 2089 2251 2422 200
381 431 485 544 607 676 750 830 915 1007 1105 1210 1321 1440 1567 1701 1844 1995 2154 2323 2501 180
186 206 229 228 252 251 277 275 303 300 331 327 360 355 391 385 424 416 458 449 493 483 530 518 569 556 610 595 652 635 696 678 742 722 790 767 840 815 892 864 945 916 1001 969 200
190
150 167 186 205 226 248 271 295 321 348 376 406 437 470 504 540 577 616 656 699 742 788 835 884 934
I Support I= S t width in cm C1= Load width in cm C2 = Load width in cm
170
119 134 149 166 184 202 222 243 265 289 313 339 365 395 425 456 488 522 558 595 633 673 715 758 803 849 897
T They are calculated for a wind pressure of p 00,5 kN/m². In the case of other wind pressures, the inertia moment w determined must be multiplied d by the corresponding factor. b
160
94 106 119 133 148 164 180 198 217 237 258 281 304 329 354 382 410 439 470 503 536 571 608 646 685 726 768 812 858 150
72 82 93 105 117 131 145 160 176 193 211 230 250 271 293 317 341 367 393 421 451 481 513 546 580 616 653 692 732 773 816 140
55 63 72 82 92 103 115 127 141 155 170 186 203 221 240 260 281 303 326 350 375 402 429 458 487 518 551 584 619 655 693 732 772 130
41 47 55 62 71 80 90 100 111 123 136 149 164 179 195 211 229 248 267 288 309 332 355 380 406 432 460 489 519 551 583 617 652 688 726 110
21 25 29 34 40 45 52 59 66 74 83 92 101 112 123 134 147 160 173 188 203 219 236 254 272 291 312 333 355 377 401 426 452 478 506 535 565 596 628 100
14 17 21 25 29 33 38 44 49 56 63 70 78 86 95 105 115 125 137 149 161 174 188 203 218 235 251 269 288 307 327 348 369 392 416 440 465 492 519 547 576 Load width a [cm]
120
30 35 41 47 54 61 69 77 86 96 107 118 130 142 156 170 185 200 217 234 252 271 291 312 334 357 381 406 432 458 486 515 546 577 609 643 678
Determination of the necessary inertia moments The determination is performed in the following order: 1. Determination of support width I in cm. 2. Determination of load width c1 and c2 in cm. 3. Determination of inertia moment Ix erf. for load width c1 according to corresponding Table I or II. 4. Determination of inertia moment Ix erf. for load width c2 according to corresponding Table I or II. 5. Addition of the necessary inertia moments determined under 3 and 4. 6. Multiplication p of the sum of the necessary inertia moments by the factorfor the wind pressure.
1,1 kN/m2
0,5 kN/m2 0,8 kN/m2
Dynamic pressure q 1,0 1,0 1,0
Pressure coefficient cp
cp
0,5 kN/m2 0,8 kN/m2 1,1 kN/m2
w=q•
Wind pressure
Conversion factors
1,0 1,6 2,2
Factor
90
9,4 12 14 17 20 24 27 32 36 41 46 52 58 65 72 80 88 97 106 115 126 137 148 160 173 186 200 214 230 246 262 280 298 317 336 357 378 400 423 447 471 497 523 80
9,2 11 14 16 19 22 26 29 34 38 43 48 54 60 66 73 80 88 96 105 114 124 134 145 156 168 180 193 207 221 236 252 268 285 302 320 339 359 379 400 422 445 469 70
8,8 11 13 15 18 20 24 27 31 34 39 43 48 54 59 65 72 79 86 93 101 110 119 128 138 149 160 171 183 196 209 222 237 251 267 283 299 317 334 353 372 392 413 60
8,1 9,7 12 14 15 18 21 24 27 30 34 38 42 47 52 57 63 68 75 81 88 96 103 111 120 129 138 148 159 169 181 192 204 217 230 244 258 273 289 305 321 338 356 50
7,2 8,5 10 12 14 16 18 20 23 26 29 32 36 40 44 48 53 63 69 74 81 87 94 101 109 116 125 133 142 152 161 172 182 193 205 217 229 242 255 269 283 298 239
40
6 7,1 8,4 9,7 11 13 15 17 19 21 24 26 29 32 36 39 43 47 51 56 60 65 70 76 82 88 94 100 107 115 122 130 138 147 155 165 174 184 194 205 216 228 239
30
4,7 5,5 6,5 7,5 8,6 9,9 11 13 14 16 18 20 22 25 27 30 33 36 39 42 46 49 53 57 62 66 71 76 81 86 92 98 104 110 117 124 131 139 146 154 163 171 180
20
3,2 3,8 4,4 5,1 5,9 6,7 7,6 8,6 9,7 11 12 14 15 17 18 20 22 24 26 28 31 33 36 38 41 44 47 51 54 58 62 66 70 74 78 83 88 93 98 103 109 114 120
180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
For mullions or transoms of multi-pane fields, use Table II if all the partareas Table II are ≤ 240 cm in size. Bending f = 1/300 • I
0-8m 8-20m 20-100m
Height above ground
W50
40
6,0 7,1 8,4 9,7 11,3 12,9 14,8 17,4 20,5 23,9 27,7 31,9 36,6 41,8 47,6 53,9 60,8 68,3 76,6 85,5 95,3 106 117 129 143 157 172 188 206 224 244 265 288 312 337 364 392 422 454 487 522 559 598
Bending f = 1/300 • I ≤ 0,8 cm
Table I
Support width 1 (cm)
Support width I (cm)
www.balkan.gr Support width 1 (cm)
Table for determining the necessary inertia moments Ix req. [cm4] for aluminium = (E= 7000 kN/m2) Load case: Freely supported girder on two supports with trapezoidal or triangular load. The values indicated serve only for profile predimensioning and are no alternative to an examinable statics calculation.
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Predimensioning Table
13
140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
80 a
25 29 34 39 44 50 57 64 71 79 88 97 106 117 127 139 154 170 187 206 225 246 268 292 316 342 369 398 428 460 493 528 564 602 642 683 726 771 817 865 916 968 1022 1078 1136 1196 1258
dis25o
21 25 29 33 38 43 49 55 62 68 76 86 97 109 122 135 150 166 183 201 220 240 262 285 309 334 360 388 418 449 481 515 550 587 626 666 708 752 797 844 893 944 997 1052 1108 1167 1227
30o
20 24 27 32 36 41 46 52 58 65 72 80 90 102 114 126 140 155 171 188 206 225 245 266 288 312 337 363 391 419 450 481 514 549 585 623 662 702 745 789 835 882 932 983 1036 1090 1147
35o
19 22 26 30 34 38 43 49 54 61 67 74 84 94 105 117 130 144 158 174 191 208 227 247 267 289 312 337 362 389 417 446 477 509 542 577 614 651 691 732 774 818 864 911 960 1011 1064
40o
17 20 24 27 31 35 40 45 50 56 62 68 77 87 97 108 119 132 146 160 175 191 208 226 245 266 287 309 332 357 383 410 438 467 498 530 563 598 634 672 711 751 793 837 882 928 977
45o
16 19 22 25 28 32 36 41 46 51 58 66 75 84 94 105 116 128 141 155 170 186 202 220 238 258 278 300 323 347 372 398 425 454 483 514 547 581 616 652 690 729 770 812 856 901 948
50o
Roof angle
14 17 19 22 25 29 33 37 41 47 54 61 69 77 86 96 107 118 130 143 156 171 186 202 219 237 256 276 297 319 342 366 391 417 445 473 503 534 566 600 635 671 708 747 787 829 872
55o
12 14 17 19 22 25 28 32 37 43 49 55 63 70 79 88 97 107 118 130 142 155 169 184 199 216 233 251 270 290 311 333 356 380 405 431 458 486 515 546 578 611 645 680 717 755 794
60o
8 10 11 13 16 19 22 26 30 34 39 44 50 56 63 70 77 86 94 104 113 124 135 147 159 172 186 200 215 231 248 266 284 303 323 343 365 388 411 435 461 487 514 542 571 602 633
70o 6 8 10 12 14 17 19 23 26 30 34 39 44 49 55 61 68 75 83 91 100 109 119 129 140 152 164 176 190 204 218 234 250 267 284 302 321 341 362 383 406 429 453 477 503 530 557
80o 5 7 8 10 12 14 17 19 23 26 30 33 38 42 47 53 59 65 71 78 86 94 102 111 120 130 141 152 163 175 188 201 215 229 244 260 276 293 311 329 348 368 389 410 432 455 479
90o 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
25 29 34 39 44 50 57 64 71 79 88 97 106 117 130 145 160 177 195 215 235 257 280 304 330 357 385 415 447 480 514 550 588 628 669 712 757 803 852 902 955 1009 1065 1124 1184 1247 1312
21 25 29 33 38 43 49 55 62 70 80 91 102 115 129 143 159 176 194 213 233 254 277 301 327 353 382 411 442 475 509 545 583 622 663 705 750 796 844 894 946 999 1055 1113 1173 1235 1299
30o 20 24 27 32 36 41 46 52 58 67 76 86 97 109 122 136 151 167 184 202 222 242 264 286 311 336 363 391 421 452 484 519 554 591 630 671 713 757 803 850 900 951 1004 1059 1116 1175 1236
35o 19 22 26 30 34 38 43 49 56 64 73 83 94 105 118 131 145 161 177 195 213 233 254 276 299 323 349 376 405 435 466 499 533 569 606 645 686 728 772 818 865 915 966 1019 1074 1130 1189
40o 17 20 24 27 31 36 42 49 57 66 75 85 96 107 120 134 148 164 181 199 217 237 259 281 305 330 356 384 413 444 475 509 544 580 619 658 700 743 788 834 883 933 985 1039 1095 1153 1213
45o 16 19 22 26 31 37 43 50 58 67 76 86 97 109 122 136 151 167 184 202 221 242 263 286 310 336 336 391 420 452 484 518 554 591 630 670 713 756 802 850 899 950 1003 1058 1115 1174 1235
50o
60o
70o
80o
90o
14 17 20 24 29 34 41 47 55 63 71 81 91 103 115 128 142 157 173 190 208 227 247 269 291 315 340 367 395 424 454 486 520 555 591 629 669 710 753 798 844 892 942 993 1047 1102 1159
12 15 19 23 27 32 38 44 51 58 67 76 85 96 107 119 132 146 161 177 194 212 231 251 272 294 317 342 368 395 424 453 485 517 551 587 624 662 702 744 787 831 878 926 976 1028 1081
10 13 16 19 23 27 32 37 43 50 57 64 73 82 91 101 113 124 137 151 165 180 196 213 231 250 270 291 313 336 361 386 413 440 469 499 531 564 598 633 670 708 747 788 831 875 920
9 12 15 18 21 25 30 34 40 46 52 59 67 75 84 93 103 114 126 138 151 165 180 196 212 230 248 267 288 309 331 354 379 404 431 458 487 517 548 581 615 650 686 723 762 803 844
9 11 13 16 19 23 27 31 36 41 47 54 60 68 76 84 94 104 114 125 137 150 163 178 193 208 225 242 261 280 300 321 343 367 391 416 442 469 497 527 557 589 622 656 692 728 766
140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
80 c
25 29 34 39 44 50 57 64 71 79 88 97 108 121 135 151 167 185 204 224 245 267 291 317 343 372 401 432 465 500 536 573 613 654 697 742 788 837 887 940 994 1051 1110 1171 1234 1299 1366
dis25o 21 25 29 33 38 43 49 56 65 74 84 96 108 121 136 151 168 185 204 224 246 268 292 318 345 373 403 434 467 501 537 575 615 656 699 744 791 840 890 943 998 1055 1114 1175 1238 1303 1371
30o 20 24 27 32 36 41 47 55 63 72 83 94 106 119 133 148 164 181 200 220 240 263 286 311 337 365 394 425 457 490 526 563 601 642 684 728 774 822 871 923 976 1032 1089 1149 1211 1275 1341
35o 19 22 26 30 35 42 49 57 66 76 87 98 111 124 139 155 172 190 209 230 252 275 300 326 353 382 412 445 478 514 551 589 630 672 716 762 810 860 912 966 1022 1080 1141 1203 1268 1335 1405
40o
17 21 25 31 37 44 51 60 69 79 90 102 116 130 145 162 179 198 218 240 263 287 312 340 368 398 430 464 499 536 574 615 657 701 747 795 845 897 951 1008 1066 1127 1190 1255 1323 1393 1465
45o
17 21 26 32 38 45 53 62 72 82 94 106 120 135 151 168 186 206 227 249 273 298 325 353 383 414 447 482 518 557 597 639 683 728 776 826 878 932 989 1047 1108 1171 1236 1304 1374 1447 1522
50o
Roof angle
dis25o
Roof angle
80 b
Dynamic pressure q = 1,1 kN/m2 (building height 20-100m)
Dynamic pressure q = 0,8 kN/m2 (building height 8-20m)
55o
16 20 25 30 36 43 51 59 68 78 89 101 114 128 143 160 177 196 216 237 259 283 309 335 364 393 425 458 493 529 567 607 649 692 738 785 835 886 940 995 1053 1113 1175 1239 1306 1375 1447
55o
15 19 24 29 34 41 48 56 64 74 84 96 108 121 136 151 167 185 204 224 245 268 292 317 344 372 402 433 466 500 536 574 613 655 698 743 789 838 889 941 996 1052 1111 1172 1235 1301 1368
60o
13 17 21 25 30 36 42 49 57 65 74 84 95 107 120 133 148 163 180 198 216 236 257 280 303 328 355 382 411 441 473 507 541 578 616 655 696 739 784 830 879 929 981 1034 1090 1148 1207
70o
13 16 20 24 28 34 40 46 53 61 70 79 89 100 112 125 138 153 169 185 203 222 241 262 284 308 332 358 385 414 444 475 507 542 577 614 653 693 735 778 824 871 919 970 1022 1076 1132
80o
For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.2 For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.4
Conversion factor for increased snow loads with roof angles up to 60o (approx. values)
12 15 18 22 26 31 37 43 50 57 65 74 83 93 104 116 129 142 157 172 189 206 225 244 265 286 309 333 359 385 413 442 472 504 537 572 608 645 684 724 766 810 855 902 951 1001 1053
90o
W50
Column spasing 1(cm)
Dynamic pressure q = 0,5 kN/m2 (building height 0-8m)
Column spasing 1(cm)
Spar spacing = 80 cm
of a shed roof or inclined facade of aluminium profiles (E=7000 kN/m2) Load case: Freely supported girder on two supports, trapezoidal or triangular load Bending max f= 1/300* I (values in table apply for max. edge length of individual glazings = 240 cm) Typical snow load So= 0,75 kN/m 2 Dead weight g=0.47 kN/m 2 Vertical individual live load F=1kN
Table for determination of the necessary inertia moments Ix req. [cm4] for spars or mullions
Column spasing 1(cm)
14 Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Predimensioning, Spar Spacing 80 cm
April 2009
Column spasing 1(cm)
140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
90 a
25 29 34 39 44 50 57 64 71 79 88 98 110 124 139 155 172 190 209 230 252 276 300 326 354 383 414 446 480 516 553 592 633 675 720 766 814 865 917 971 1028 1086 1147 1210 1275 1343 1413
dis25o
21 25 29 33 38 43 49 55 64 74 84 95 108 121 136 151 168 185 204 225 246 269 293 318 345 374 404 435 468 503 539 577 617 659 702 747 794 843 895 948 1003 1060 1119 1181 1244 1310 1378
30o
20 24 27 32 36 41 46 52 60 69 79 89 101 113 127 141 157 173 191 210 230 251 274 298 323 349 377 407 438 470 504 540 577 616 656 698 742 788 836 885 937 990 1046 1103 1163 1224 1288
35o
19 22 26 30 34 38 43 49 56 64 73 83 93 105 117 131 145 161 177 195 213 233 254 276 299 324 350 377 406 436 467 500 535 571 608 646 688 731 775 821 869 918 970 1023 1078 1135 1194
40o
17 20 24 27 31 35 40 45 51 59 67 76 86 96 108 120 133 148 163 179 196 214 233 253 275 297 321 346 373 400 429 459 491 524 559 595 632 671 712 754 798 843 890 939 990 1042 1097
45o
16 19 22 25 28 32 37 43 49 57 65 74 83 94 105 117 129 143 158 173 109 208 226 246 267 289 312 336 362 388 416 446 477 509 542 577 613 651 691 732 774 818 864 912 961 1012 1064
50o
Roof angle
Dynamic pressure q = 0,5 kN/m2 (building height 0-8m)
Spar spacing = 90 cm
14 17 19 22 25 29 34 39 46 52 60 68 77 86 96 107 119 132 145 160 175 191 208 226 245 266 287 309 333 357 383 410 439 468 499 531 565 599 636 673 712 753 795 839 884 931 979
55o
12 14 17 19 22 26 31 36 41 48 54 62 70 78 88 98 108 120 132 145 159 174 189 206 223 242 261 281 303 325 349 373 399 426 454 483 514 545 578 613 648 685 724 763 805 847 891
60o
8 10 12 15 17 21 24 29 33 38 43 49 56 62 70 78 86 96 105 116 127 139 151 164 178 193 208 224 241 259 278 298 318 340 362 385 410 435 461 489 517 546 577 609 642 675 711
70o 7 8 11 13 15 18 22 25 29 33 38 43 49 55 62 69 76 84 93 102 112 122 133 145 157 170 183 198 213 228 245 262 280 299 319 339 361 383 406 430 455 481 508 536 565 595 626
80o 5 7 9 11 13 16 18 22 25 29 33 37 42 47 53 59 65 72 80 88 96 105 114 124 135 146 157 170 183 196 210 225 241 257 274 291 310 329 349 370 391 413 436 460 485 511 538
90o 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
90 b
25 29 34 39 44 50 57 64 71 79 90 102 115 129 145 161 179 198 218 240 263 287 313 340 369 400 431 465 500 538 576 617 660 704 750 799 849 901 956 1013 1071 1133 1196 1262 1330 1400 1473
dis25o 21 25 29 33 38 43 50 59 68 78 89 101 114 128 143 160 177 196 216 238 260 285 310 337 366 396 427 461 469 532 571 611 653 697 743 791 841 893 947 1003 1061 1122 1185 1250 1317 1387 1459
30o 20 24 27 32 36 41 48 56 64 74 85 96 109 122 137 152 169 187 206 226 248 271 295 321 348 376 407 438 472 507 543 581 621 663 707 753 800 849 901 954 1010 1067 1127 1189 1253 1319 1388
35o 19 22 26 30 34 39 46 54 62 71 81 92 104 117 131 146 162 180 198 218 238 260 284 309 335 362 391 422 454 487 522 559 598 638 680 724 770 817 867 918 971 1027 1084 1144 1205 1269 1335
40o 17 20 24 28 33 40 47 55 63 73 83 94 107 120 134 149 166 183 202 222 243 266 290 315 341 369 399 430 463 497 533 571 610 651 694 739 785 834 884 936 991 1047 1106 1167 1230 1295 1362
45o 16 19 23 28 34 41 48 56 64 74 85 96 108 122 136 152 169 187 206 226 248 270 295 320 348 376 406 438 471 506 543 581 621 663 706 752 799 849 900 953 1009 1066 1126 1188 1252 1318 1387
50o
Roof angle
Dynamic pressure q = 0,8 kN/m2 (building height 8-20m)
of a shed roof or inclined facade of aluminium profiles (E=7000 kN/m2) Load case: Freely supported girder on two supports, trapezoidal or triangular load Bending max f= 1/300* I (values in table apply for max. edge length of individual glazings = 240 cm) Typical snow load So= 0,75 kN/m 2 Dead weight g=0.47 kN/m 2 Vertical individual live load F=1kN
Column spasing 1(cm)
www.balkan.gr 14 18 22 27 32 38 45 52 60 70 79 90 102 114 128 143 158 175 193 212 232 254 277 301 326 353 381 411 442 475 509 545 583 622 663 706 750 797 845 895 947 1001 1057 1115 1175 1238 1302
55o 13 16 20 25 30 35 42 49 56 65 74 84 95 107 119 133 148 163 180 198 217 237 258 280 304 329 356 383 412 443 475 508 543 580 618 658 700 743 788 834 883 933 986 1040 1096 1154 1214
60o 11 14 17 21 25 30 36 41 48 55 63 72 81 91 102 113 126 139 153 168 184 201 220 239 259 280 303 326 351 377 404 433 463 494 526 560 596 632 671 710 752 794 839 885 933 982 1033
70o 10 13 16 19 23 28 33 38 44 51 58 66 74 83 93 104 115 128 141 154 169 185 202 219 238 257 278 299 322 346 371 397 425 453 483 514 547 580 615 652 690 729 770 812 856 901 948
80o 9 12 14 18 21 25 30 35 40 46 52 60 67 76 85 94 105 116 128 140 154 168 183 199 216 233 252 272 292 314 337 360 385 411 438 466 496 526 528 591 626 661 698 737 776 818 860
90o 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
90 c
25 29 34 39 44 50 57 64 71 82 94 106 120 135 151 168 187 206 227 250 274 299 326 354 384 416 449 484 521 560 600 643 687 733 781 832 884 939 996 1055 1116 1180 1246 1314 1385 1458 1534
dis25o 21 25 29 33 38 45 53 62 72 82 94 107 120 135 151 169 187 207 228 251 275 300 327 356 386 418 451 486 523 562 602 645 689 736 784 835 887 942 999 1058 1120 1184 1250 1319 1390 1463 1540
30o 20 24 27 32 37 44 52 60 70 80 92 104 118 132 148 165 183 203 223 245 269 294 320 348 377 409 441 476 512 550 589 631 674 720 767 817 868 922 978 1035 1096 1158 1223 1290 1360 1432 1506
35o 19 22 26 32 39 46 54 63 73 84 96 109 123 139 155 173 192 212 234 257 282 308 335 364 395 428 462 498 536 576 617 661 706 754 803 855 909 965 1024 1084 1147 1213 1281 1351 1424 1499 1577
40o
18 22 28 34 40 48 57 66 76 88 100 114 129 145 162 180 200 221 244 268 294 321 350 380 412 446 482 519 559 600 644 689 737 786 838 892 948 1007 1068 1131 1197 1265 1336 1409 1485 1564 1645
45o
18 23 29 35 42 50 59 69 79 91 104 118 134 150 168 187 208 230 253 279 305 333 363 395 428 464 501 540 581 624 669 716 765 817 871 927 985 1046 1109 1175 1243 1314 1388 1464 1543 1625 1709
50o
Roof angle 55o 18 22 27 33 40 47 56 65 75 87 99 113 127 143 160 178 198 219 241 265 290 317 345 375 407 441 476 513 552 593 636 681 727 776 827 881 936 994 1054 1117 1182 1249 1319 1391 1466 1544 1624
Dynamic pressure q = 1,1 kN/m2 (building height 20-100m)
17 21 26 31 38 45 53 62 71 82 94 106 120 135 151 168 187 207 228 250 274 300 327 355 385 417 450 485 522 561 601 644 688 734 783 833 886 940 997 1056 1118 1181 1247 1316 1387 1460 1536
60o
15 18 23 28 33 40 47 54 63 72 83 94 106 119 133 149 165 182 201 221 242 264 288 313 340 368 397 428 461 495 530 568 607 648 691 735 781 830 880 932 986 1042 1101 1161 1224 1289 1356
70o
14 17 21 26 31 37 44 51 59 68 78 88 99 112 125 139 155 171 188 207 227 248 270 294 318 345 372 401 432 464 497 532 569 607 647 689 732 778 825 874 924 977 1032 1088 1147 1208 1271
80o
For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.2 For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.4
Conversion factor for increased snow loads with roof angles up to 60o (approx. values)
Column spasing 1(cm)
Table for determination of the necessary inertia moments Ix req. [cm2] for spars or mullions
13 16 20 24 29 35 41 47 55 63 72 82 93 104 116 130 144 159 175 193 211 231 251 273 296 321 346 373 402 432 463 495 530 565 602 641 682 724 768 813 860 909 960 1013 1068 1124 1183
90o
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Predimensioning, Spar Spacing 90 cm
W50 15
140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
100 a
25 29 34 39 44 50 57 64 72 83 94 107 121 137 153 170 189 209 231 254 278 304 332 361 391 424 458 493 531 570 612 655 700 748 797 848 902 958 1016 1076 1139 1204 1271 1341 1414 1489 1566
dis25o
21 25 29 33 38 44 52 60 70 81 92 105 118 133 149 166 185 204 225 248 272 297 324 352 382 413 446 481 518 557 597 639 683 729 778 828 880 934 991 1050 1111 1175 1240 1309 1379 1452 1582
30o
20 24 27 32 36 41 48 56 65 75 86 98 111 124 139 155 173 191 211 232 254 277 302 329 357 386 417 450 484 520 558 597 638 682 727 773 822 873 926 981 1038 1098 1159 1223 1289 1357 1428
35o
19 22 26 30 34 38 45 52 61 70 80 91 103 115 129 144 160 177 195 215 235 257 280 305 331 358 387 417 449 482 517 554 592 632 674 717 763 810 859 910 963 1018 1075 1134 1195 1259 1324
40o
17 20 24 27 31 35 41 48 56 64 73 83 94 106 119 132 147 163 179 197 216 236 257 280 304 329 355 383 412 443 475 508 544 580 619 659 700 743 789 835 884 935 987 1041 1097 1156 1216
45o
16 19 22 25 28 34 40 47 54 62 71 81 91 103 115 128 143 158 174 191 210 229 250 272 295 319 345 372 400 430 461 494 528 563 600 639 680 722 765 811 858 907 958 1011 1065 1122 1180
50o
14 17 19 22 26 31 37 43 50 57 65 74 84 95 106 118 131 145 160 176 193 211 230 250 271 294 317 342 368 395 424 454 486 518 552 588 625 664 704 746 790 835 881 930 980 1032 1086
55o
12 14 17 20 24 28 33 39 45 52 60 68 77 86 96 108 119 132 146 160 176 192 209 228 247 267 289 311 335 360 386 413 442 472 503 535 569 604 641 679 718 760 802 846 892 939 988
60o
8 10 13 16 19 23 27 31 36 42 48 54 61 69 77 86 95 105 116 128 140 153 167 181 197 213 230 248 267 287 308 330 352 376 401 427 454 482 511 541 573 606 640 675 711 749 788
70o 7 9 11 14 17 20 23 27 32 37 42 48 54 60 68 75 84 93 102 112 123 135 147 160 173 188 203 219 235 253 271 290 310 331 353 376 400 424 450 477 504 533 563 594 626 659 694
80o 6 8 10 12 14 17 20 24 27 31 36 41 46 52 58 65 72 80 88 97 106 116 126 137 149 161 174 188 202 217 233 249 266 284 303 323 343 364 387 409 433 458 484 510 538 566 596
90o 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
25 29 34 39 44 50 57 67 75 86 98 112 127 142 159 178 197 218 241 265 290 317 346 376 408 442 477 514 554 595 638 683 730 779 831 885 940 999 1059 1122 1187 1255 1326 1398 1474 1552 1633
21 25 29 33 38 44 55 64 74 85 98 111 125 141 158 176 185 216 239 262 287 314 342 372 404 437 473 510 548 589 632 676 723 772 823 876 931 989 1049 1111 1176 1243 1313 1385 1460 1537 1618
30o 20 24 27 32 36 44 52 61 71 81 93 105 119 134 150 167 189 206 227 249 273 299 326 354 384 416 450 485 522 560 601 644 688 734 783 834 886 941 998 1057 1119 1183 1249 1318 1389 1463 1539
35o 19 22 26 30 34 38 45 58 68 78 89 101 115 129 144 161 179 198 218 240 263 288 313 341 370 400 433 466 502 539 578 619 662 707 753 802 853 905 960 1017 1076 1138 1202 1268 1336 1407 1480
40o 17 20 25 30 36 43 51 60 69 80 91 104 117 132 147 164 183 202 223 245 268 293 320 348 377 408 441 476 512 550 590 632 675 721 768 818 870 924 979 1038 1098 1161 1226 1293 1363 1435 1510
45o 16 20 25 31 37 44 52 61 70 81 93 105 119 134 150 167 186 206 227 249 273 299 326 354 384 416 449 484 521 560 601 643 688 734 782 833 885 940 997 1057 1118 1182 1248 1317 1388 1462 1538
50o
60o
70o
80o
90o
15 19 24 29 35 41 49 57 66 76 87 99 112 126 141 157 174 193 213 234 256 280 306 332 361 390 422 455 489 526 564 604 645 689 734 782 831 883 936 992 1050 1110 1172 1236 1303 1372 1444
14 18 22 27 32 39 45 53 62 71 81 92 104 117 131 146 163 180 198 218 239 261 285 310 336 364 393 424 456 490 526 563 602 642 685 729 775 823 873 925 978 1034 1092 1152 1215 1279 1346
12 15 19 23 28 33 39 45 52 60 69 79 89 100 112 125 138 153 169 186 204 222 243 264 286 310 335 361 388 417 447 479 512 547 583 620 660 700 743 787 833 880 930 981 1034 1089 1146
11 14 17 21 25 30 36 42 48 55 63 72 81 92 103 114 127 141 155 170 187 204 223 242 263 284 307 331 356 383 411 440 470 502 535 569 605 643 682 722 764 808 853 900 949 999 1051
10 13 16 19 23 27 32 38 44 50 58 65 74 83 93 104 115 128 141 155 169 185 202 220 238 258 279 300 323 347 372 399 426 455 485 517 549 583 618 655 693 733 774 817 861 906 954
140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
100 c
25 29 34 39 44 50 57 67 78 90 103 117 132 148 166 185 206 227 251 276 302 330 260 392 425 460 497 536 577 620 664 711 761 812 865 921 980 1040 1103 1169 1237 1307 1381 1457 1535 1617 1701
dis25o 21 25 29 33 38 44 52 67 78 90 103 117 132 149 167 186 206 228 252 277 303 332 361 393 426 462 499 538 579 622 667 714 763 815 868 925 983 1044 1107 1173 1241 1312 1386 1462 1541 1622 1707
30o 20 24 27 33 40 48 56 66 77 88 101 114 129 146 163 182 202 223 246 271 297 324 354 385 417 452 488 526 566 608 652 698 747 797 850 905 962 1021 1083 1147 1214 1284 1356 1430 1507 1587 1670
35o 19 23 28 35 42 50 59 69 80 92 105 120 135 152 171 190 211 234 258 283 311 340 370 403 437 473 511 551 593 637 683 731 782 835 890 947 1007 1069 1134 1201 1271 1344 1419 1497 1578 1662 1749
40o
19 24 30 36 44 52 62 72 84 96 110 125 141 159 178 198 220 244 269 296 324 354 386 420 456 493 533 575 618 664 712 763 815 870 928 988 1050 1115 1183 1253 1326 1402 1480 1562 1646 1733 1824
45o
20 25 31 38 46 54 64 75 87 100 114 130 147 165 185 206 229 253 279 307 337 368 401 436 473 513 554 597 643 690 740 793 847 905 964 1027 1091 1159 1229 1302 1378 1457 1538 1623 1711 1801 1895
50o
Roof angle
dis25o
Roof angle
100 b
Dynamic pressure q = 1,1 kN/m2 (building height 20-100m)
Dynamic pressure q = 0,8 kN/m2 (building height 8-20m)
55o
19 24 29 36 43 52 61 71 83 95 109 123 140 157 176 196 218 241 266 292 320 350 381 415 450 487 526 567 611 656 704 753 805 860 916 976 1037 1101 1168 1238 1310 1384 1462 1542 1626 1712 1801
55o
18 22 28 34 41 49 58 64 78 90 103 117 132 148 166 185 206 228 251 276 303 331 361 392 426 461 498 537 577 620 665 712 762 813 867 923 981 1042 1105 1170 1239 1309 1383 1459 1537 1619 1703
60o
16 20 24 30 36 43 51 59 69 79 91 103 116 131 147 164 182 201 222 244 267 292 318 346 376 407 439 474 510 547 587 629 672 717 765 814 866 919 975 1033 1093 1155 1220 1287 1357 1429 1503
70o
15 18 23 28 34 40 48 56 65 74 85 97 109 123 138 153 170 188 208 228 250 274 298 324 352 381 412 444 478 513 550 589 630 672 717 763 811 862 914 968 1024 1083 1144 1207 1272 1339 1409
80o
For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.2 For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.4
Conversion factor for increased snow loads with roof angles up to 60o (approx. values)
14 17 21 26 32 38 44 52 60 69 79 90 102 114 128 143 158 175 193 213 233 255 278 302 328 355 383 413 445 487 512 548 586 626 667 710 755 802 850 901 953 1008 1064 1123 1183 1246 1311
90o
W50
Column spasing 1(cm)
Roof angle
Dynamic pressure q = 0,5 kN/m2 (building height 0-8m)
Column spasing 1(cm)
Spar spacing = 100 cm
of a shed roof or inclined facade of aluminium profiles (E=7000 kN/m2) Load case: Freely supported girder on two supports, trapezoidal or triangular load Bending max f= 1/300* I (values in table apply for max. edge length of individual glazings = 240 cm) Typical snow load So= 0,75 kN/m 2 Dead weight g=0.47 kN/m 2 Vertical individual live load F=1kN
Table for determination of the necessary inertia moments Ix req. [cm2] for spars or mullions
901Column spasing 1(cm)
16 Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Predimensioning, Spar Spacing 100 cm
April 2009
Column spasing 1(cm)
140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
110 a
25 29 34 39 44 50 57 67 78 89 102 116 132 148 166 186 206 228 252 277 304 332 362 394 428 463 501 540 581 625 670 718 767 819 873 930 989 1050 1114 1180 1249 1321 1395 1472 1551 1634 1719
dis25o
21 25 29 33 38 44 56 65 76 87 100 114 129 145 162 181 201 223 246 270 296 324 354 385 417 452 489 527 567 609 654 700 749 799 852 907 965 1025 1087 1151 1219 1288 1361 1436 1513 1594 1677
30o
20 24 27 32 37 44 52 61 71 81 93 106 120 135 152 169 188 208 230 253 277 303 330 359 390 422 457 492 530 569 611 654 700 747 796 848 902 957 1016 1076 1139 1204 1272 1342 1414 1489 1567
35o
19 22 26 30 34 41 48 56 66 76 87 98 111 125 141 157 174 193 213 234 257 281 306 333 362 392 423 457 491 528 567 607 649 693 738 786 836 888 942 998 1056 1117 1179 1244 1312 1381 1453
40o
16 19 22 25 30 36 43 50 58 67 77 88 99 112 125 140 155 172 190 209 229 250 273 297 322 349 377 407 438 471 505 541 578 617 658 701 745 791 839 889 941 995 1051 1109 1169 1231 1295
50o
Roof angle
17 20 24 27 31 37 44 52 60 69 79 90 102 115 129 144 160 177 196 215 236 258 281 306 332 360 389 419 451 485 520 557 596 636 678 722 768 815 865 916 970 1025 1083 1142 1204 1268 1334
45o
Dynamic pressure q = 0,5 kN/m2 (building height 0-8m)
Spar spacing = 110 cm
14 17 19 23 28 33 39 46 54 62 71 81 91 103 115 129 143 158 175 192 211 230 251 273 297 321 347 374 403 433 465 497 532 568 606 645 686 728 772 818 866 916 967 1020 1075 1133 1192
55o
12 14 17 21 25 30 36 42 49 56 65 73 83 94 105 117 130 144 159 175 192 210 229 249 270 292 316 341 367 394 423 453 484 517 551 587 624 663 703 745 788 833 880 928 979 1031 1084
60o
9 11 14 17 20 24 29 34 39 45 51 59 66 75 84 93 104 115 127 139 153 167 182 198 215 233 252 272 292 314 337 361 386 412 439 468 497 528 560 594 628 664 702 740 780 822 865
70o 8 10 12 15 18 21 25 30 34 40 45 52 58 66 74 82 91 101 112 123 135 147 161 175 190 205 222 239 257 277 297 318 340 363 387 412 438 465 493 523 553 585 618 652 687 724 761
80o 6 8 10 13 15 18 22 25 29 34 39 44 50 56 63 71 78 87 96 105 116 126 138 150 163 176 191 205 221 238 255 273 292 312 332 354 376 400 424 449 475 503 531 560 590 622 654
90o 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
110 b
25 29 34 39 44 50 59 70 81 93 107 121 137 155 173 193 215 238 263 289 317 346 378 411 446 483 522 563 606 651 699 748 800 854 911 970 1031 1095 1161 1231 1302 1377 1454 1534 1617 1703 1792
dis25o 21 25 29 34 42 50 59 69 80 92 106 120 136 153 172 192 213 236 260 286 314 343 374 407 442 479 517 558 600 645 692 741 792 846 902 960 1021 1084 1150 1219 1290 1364 1440 1520 1602 1687 1775
30o 20 24 27 33 40 47 56 66 76 88 101 114 129 146 163 182 203 224 248 272 299 326 356 387 420 455 492 531 571 614 658 705 754 805 858 914 971 1032 1094 1160 1227 1297 1370 1446 1524 1605 1689
35o 19 22 26 31 38 46 54 63 73 84 97 110 125 140 157 175 195 216 238 262 287 314 343 373 404 438 473 510 549 590 633 678 725 774 826 879 935 993 1053 1116 1181 1248 1318 1391 1466 1544 1625
40o 17 21 26 32 39 46 55 64 75 86 99 112 127 143 160 179 199 220 243 267 293 320 349 380 413 447 483 521 561 602 646 692 740 790 842 897 953 1013 1074 1138 1204 1273 1345 1419 1496 1575 1657
45o 17 21 27 33 40 47 56 66 76 88 100 114 129 146 163 182 202 224 247 272 298 326 356 387 420 455 492 530 571 613 658 704 753 804 857 913 971 1031 1094 1159 1226 1296 1369 1445 1523 1604 1687
50o
Roof angle
Dynamic pressure q = 0,8 kN/m2 (building height 8-20m)
of a shed roof or inclined facade of aluminium profiles (E=7000 kN/m2) Load case: Freely supported girder on two supports, trapezoidal or triangular load Bending max f= 1/300* I (values in table apply for max. edge length of individual glazings = 240 cm) Typical snow load So= 0,75 kN/m 2 Dead weight g=0.47 kN/m 2 Vertical individual live load F=1kN
Column spasing 1(cm)
www.balkan.gr 16 20 25 31 37 44 52 61 71 82 94 107 121 137 153 171 190 210 232 255 280 306 334 363 394 427 461 498 536 576 617 661 707 755 805 857 911 968 1027 1088 1151 1217 1285 1356 1430 1506 1584
55o 15 19 23 29 35 41 49 57 67 77 88 100 113 128 143 159 177 196 216 238 261 286 311 339 368 398 430 464 499 537 576 617 659 704 750 799 850 902 957 1014 1073 1135 1198 1264 1333 1404 1477
60o 12 16 20 24 29 35 42 49 57 65 75 85 96 109 122 136 151 167 184 203 222 243 265 288 313 339 366 395 425 457 490 525 561 599 639 680 723 768 815 863 914 966 1020 1076 1134 1195 1257
70o 11 15 18 22 27 32 38 45 52 60 69 78 88 100 112 125 138 153 169 186 204 223 243 265 287 311 336 362 390 419 450 482 515 550 586 624 664 705 748 792 838 886 936 988 1041 1097 1154
80o 10 13 16 20 25 29 35 41 47 54 62 71 80 90 101 113 126 139 153 169 185 202 221 240 261 282 305 329 354 380 408 437 467 499 532 566 602 639 678 719 760 804 849 896 944 995 1047
90o 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
110 c
25 29 34 39 44 52 62 72 84 97 111 126 143 161 181 202 224 248 274 301 330 361 394 428 465 503 544 586 631 678 728 779 833 890 948 1010 1074 1140 1210 1282 1357 1434 1515 1598 1685 1774 1867
dis25o 21 25 30 36 44 52 62 73 84 97 112 127 144 162 181 202 225 249 275 302 331 362 395 430 466 505 546 589 634 681 730 782 836 893 952 1013 1078 1144 1214 1286 1361 1439 1520 1604 1690 1780 1873
30o 20 24 29 35 43 51 61 71 83 95 109 124 141 158 177 198 220 243 269 295 324 354 386 420 456 494 534 576 620 666 714 765 818 873 931 991 1054 1120 1188 1258 1332 1408 1487 1569 1654 1742 1833
35o
19 24 30 37 45 54 64 74 87 100 114 130 147 166 186 207 230 255 281 309 339 371 405 440 478 517 559 603 649 697 748 801 857 915 975 1038 1104 1172 1244 1318 1395 1474 1557 1643 1732 1824 1919
40o
20 25 32 39 47 56 66 78 90 104 119 136 153 173 194 216 240 266 293 323 354 387 422 459 498 540 583 629 677 727 780 835 893 954 1017 1083 1151 1223 1297 1374 1454 1538 1624 1713 1806 1902 2001
45o
21 26 33 40 49 58 69 81 94 108 124 141 159 180 201 225 250 276 305 335 368 402 439 477 518 561 606 653 703 756 811 868 928 991 1057 1125 1197 1271 1348 1438 1511 1598 1688 1781 1877 1977 2080
50o
Roof angle 55o 20 25 31 38 46 55 65 77 89 103 118 134 152 171 191 213 237 263 290 319 349 382 417 453 492 533 576 621 668 718 770 825 882 942 1004 1069 1137 1208 1281 1357 1436 1519 1604 1692 1784 1879 1977
Dynamic pressure q = 1,1 kN/m2 (building height 20-100m)
18 24 29 36 44 52 62 73 84 97 111 127 143 161 181 202 224 248 274 301 330 361 394 429 465 504 545 587 632 679 729 780 834 891 950 1011 1075 1142 1211 1284 1358 1436 1517 1600 1687 1777 1869
60o
16 21 26 32 39 46 55 64 74 86 98 112 126 142 160 178 198 219 242 266 292 319 348 378 411 445 481 518 558 599 643 689 736 786 838 892 949 1008 1069 1133 1199 1267 1338 1412 1489 1568 1650
70o
15 20 24 30 36 43 51 60 70 80 92 105 119 133 150 167 186 205 227 249 273 299 326 355 385 417 450 486 523 562 603 645 690 737 786 836 889 945 1002 1062 1124 1188 1255 1324 1395 1469 1546
80o
For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.2 For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.4
Conversion factor for increased snow loads with roof angles up to 60o (approx. values)
901Column spasing 1(cm)
Table for determination of the necessary inertia moments Ix req. [cm2] for spars or mullions
14 18 23 28 34 40 48 56 65 75 86 97 110 124 139 155 173 191 211 232 254 278 303 330 358 388 419 452 487 523 561 601 642 686 731 778 828 879 932 988 1046 1106 1168 1232 1299 1368 1439
90o
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Predimensioning, Spar Spacing 110 cm
W50 17
140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
120 a
Column spasing 1(cm)
25 29 34 39 44 51 61 71 83 96 110 125 142 160 179 200 223 247 272 300 329 360 392 427 464 502 543 586 631 678 727 779 833 890 949 1011 1075 1142 1211 1283 1358 1436 1517 1601 1688 1777 1870
dis25o
21 25 29 33 42 50 59 69 81 93 107 122 138 156 175 195 217 241 266 292 321 351 383 417 452 490 530 572 615 661 710 760 813 868 926 986 1049 1114 1182 1252 1325 1401 1480 1562 1646 1734 1825
30o
20 24 27 32 39 47 55 65 76 87 100 114 129 146 163 182 203 225 248 273 300 328 358 389 423 458 495 534 575 648 663 710 760 811 865 921 980 1041 1104 1170 1238 1309 1383 1459 1539 1620 1705
35o
19 22 26 30 36 43 51 60 70 81 93 106 120 135 152 169 188 209 230 253 378 304 332 361 392 425 459 495 533 573 615 659 705 752 802 854 909 965 1024 1085 1148 1214 1283 1353 1427 1503 1581
40o
17 20 24 27 33 40 47 55 64 74 85 97 110 124 139 155 173 191 211 233 255 279 305 332 360 390 422 455 490 526 565 605 647 691 737 784 834 886 940 996 1054 1115 1178 1243 1310 1380 1452
45o
16 19 22 26 32 39 46 54 62 72 83 94 107 120 135 151 168 186 205 226 248 271 296 322 349 379 409 441 475 511 548 587 628 670 715 761 810 860 912 967 1023 1082 1143 1206 1271 1339 1409
50o
Roof angle
Dynamic pressure q = 0,5 kN/m2 (building height 0-8m)
Spar spacing = 120 cm
14 17 20 24 30 35 42 49 57 66 76 87 98 111 124 139 154 171 189 208 228 249 272 296 322 348 376 406 437 470 504 540 578 617 658 701 745 791 840 890 942 996 1052 1110 1170 1232 1297
55o
12 14 18 22 32 32 38 45 52 60 69 79 89 101 113 126 140 156 172 189 207 227 248 269 293 317 343 370 398 428 459 492 526 561 599 638 678 720 764 810 857 906 957 1010 1065 1121 1180
60o
9 11 14 18 21 26 30 36 42 48 55 63 71 80 90 101 112 124 137 151 165 181 197 215 233 253 273 295 317 341 366 392 419 448 477 508 541 574 609 646 683 722 763 805 849 894 941
70o 8 10 13 16 23 23 27 32 37 42 49 55 63 71 79 89 99 109 121 133 146 159 174 189 205 223 241 259 279 300 322 345 369 394 420 448 476 506 536 568 602 636 672 709 747 787 828
80o 7 9 11 13 19 19 23 27 32 36 42 48 54 61 68 76 85 94 104 114 125 137 149 163 176 191 207 223 240 258 277 277 317 339 361 385 409 434 461 488 517 547 577 609 642 676 712
90o 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
120 b
25 29 34 39 44 53 63 74 86 100 114 130 148 167 187 209 232 257 284 312 343 375 409 445 484 524 566 611 658 707 758 812 869 928 989 1054 1120 1190 1263 1338 1416 1497 1582 1669 1759 1853 1950
dis25o 21 25 29 36 44 53 63 74 86 99 113 129 146 165 185 207 230 255 281 310 340 372 405 441 479 519 561 605 651 700 751 805 861 919 980 1044 1110 1179 1251 1325 1403 1483 1567 1653 1743 1836 1932
30o 20 24 28 34 42 50 60 70 81 94 108 123 139 157 176 197 219 242 268 294 323 353 386 420 456 494 534 576 620 666 715 766 819 874 932 993 1056 1122 1190 1261 1335 1411 1490 1573 1658 1746 1838
35o 19 22 27 33 40 48 57 67 78 90 104 118 134 151 169 189 210 233 257 283 311 340 371 404 438 475 513 554 596 641 688 736 788 841 897 897 1016 1079 1145 1213 1284 1358 1434 1513 1595 1680 1768
40o 17 22 27 34 41 49 58 69 80 92 106 121 137 154 173 193 215 238 263 289 317 347 378 412 447 484 524 565 608 654 701 751 804 858 915 915 1036 1101 1168 1237 1310 1385 1463 1544 1627 1714 1803
45o 17 22 28 34 42 50 60 70 81 94 108 123 139 157 176 196 219 242 267 294 323 353 385 419 455 493 533 575 619 666 714 765 818 874 922 922 1055 1121 1189 1260 1333 1410 1489 1572 1657 1745 1836
50o
Roof angle
Dynamic pressure q = 0,8 kN/m2 (building height 8-20m)
of a shed roof or inclined facade of aluminium profiles (E=7000 kN/m2) Load case: Freely supported girder on two supports, trapezoidal or triangular load Bending max f= 1/300* I (values in table apply for max. edge length of individual glazings = 240 cm) Typical snow load So= 0,75 kN/m 2 Dead weight g=0.47 kN/m 2 Vertical individual live load F=1kN
Table for determination of the necessary inertia moments Ix req. [cm2] for spars or mullions
Column spasing 1(cm)
16 21 26 32 39 47 56 66 76 88 101 115 131 147 165 184 205 227 251 276 303 332 362 394 427 463 500 540 581 625 670 718 768 820 875 875 990 1052 1116 1183 1252 1324 1398 1475 1555 1638 1724
55o 15 19 24 30 37 44 52 61 71 82 94 107 122 137 154 172 191 212 234 258 283 309 337 367 398 432 467 503 542 583 625 669 716 765 815 868 923 981 1041 1103 1167 1234 1303 1375 1450 1527 1607
60o 13 17 21 26 31 37 44 52 61 70 80 91 104 117 131 146 163 180 199 219 240 263 287 312 339 367 397 428 461 496 532 570 609 651 694 739 786 835 886 939 993 1050 1109 1171 1234 1300 1368
70o 12 15 19 24 29 34 41 48 56 64 74 84 95 107 120 134 149 166 183 201 221 241 263 287 311 337 365 393 423 455 488 523 559 597 637 678 721 766 813 861 912 964 1018 1074 1133 1193 1255
80o 11 14 17 21 26 31 37 43 50 58 67 76 86 97 109 122 136 150 166 182 200 219 239 260 282 306 331 357 384 413 443 474 507 542 578 615 654 695 737 781 827 874 924 924 1027 1082 1139
90o 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
120 c
25 29 34 39 46 56 66 77 90 104 119 136 154 174 195 217 242 268 296 325 357 391 426 464 504 546 590 636 685 736 790 846 905 966 1031 1097 1167 1240 1315 1394 1475 1560 1647 1738 1833 1930 2031
dis25o 21 25 31 38 46 56 66 78 90 104 120 136 154 174 195 218 243 269 297 327 358 392 428 466 505 547 592 638 687 739 793 849 908 970 1034 1101 1171 1244 1320 1398 1480 1565 1653 1745 1839 1937 2038
30o 20 24 30 37 45 54 65 76 88 102 117 133 151 170 191 213 237 263 290 320 351 384 418 455 494 536 579 625 673 723 776 831 888 949 1012 1077 1146 1217 1291 1368 1448 1531 1617 1707 1799 1895 1994
35o 20 25 32 39 48 57 68 79 93 107 123 140 158 178 200 223 249 275 304 335 367 402 438 477 518 561 606 654 704 757 812 870 930 994 1059 1128 1200 1274 1352 1433 1516 1603 1694 1787 1884 1984 2088
40o
20 26 33 41 50 60 71 83 96 111 128 146 165 186 209 233 259 287 317 349 383 419 457 497 540 585 632 682 737 789 847 907 970 1036 1105 1177 1251 1329 1410 1494 1582 1672 1766 1864 1965 2070 2178
45o
21 27 34 42 52 62 73 86 100 116 133 151 172 193 217 242 269 298 330 363 398 435 475 517 561 608 657 709 763 820 880 943 1008 1077 1148 1223 1300 1381 1465 1553 1644 1738 1836 1937 2042 2151 2263
50o
Roof angle 55o 20 26 33 40 49 59 70 82 95 110 126 144 163 184 206 230 256 284 313 345 378 414 451 491 533 578 624 674 725 780 836 896 958 1023 1091 1162 1236 1313 1393 1476 1562 1652 1744 1841 1941 2044 2151
Dynamic pressure q = 1,1 kN/m2 (building height 20-100m)
19 31 31 38 46 56 66 77 90 104 119 136 154 174 195 218 242 268 296 326 358 391 427 465 504 546 591 637 686 737 791 847 906 968 1032 1099 1169 1241 1317 1396 1477 1562 1650 1741 1835 1933 2034
60o
17 27 27 34 41 49 58 68 80 92 105 120 136 153 172 192 214 237 261 288 316 345 377 410 445 482 521 562 605 651 698 748 800 854 911 970 1031 1095 1162 1232 1304 1378 1456 1536 1619 1706 1795
70o
16 26 26 32 38 46 55 64 75 86 99 113 128 144 161 180 200 222 245 270 296 324 353 384 417 252 488 527 567 610 654 701 750 800 854 909 967 1027 1089 1154 1222 1292 1365 1440 1518 1599 1682
80o
For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.2 For typical snow load So=1,00 kN/m2, the values in the table must be multiplied by 1.4
Conversion factor for increased snow loads with roof angles up to 60o (approx. values)
15 24 24 29 36 43 51 60 69 80 92 105 119 134 150 168 186 206 228 251 275 301 329 358 388 421 455 490 528 568 609 652 698 745 794 846 900 956 1014 1074 1137 1202 1270 1340 1413 1488 1566
90o
W50
901Column spasing 1(cm)
18 Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Statics Predimensioning, Spar Spacing 120 cm
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Calculation of the heat transmission coefficient Ucw
W50
19
Ucw value (CURTAIN WALLING) to prEN 13947 prEn 13947 defines a method for determining the heat transmission coefficient Ucw of a curtain facade system consisting of glass fillings and / or non-transparent fillings in frames or sashes.
Window
Frame
Window
The heat transmission coefficient Ucw of a curtain facade system is calculated using the following equation:
Ucw=
ΣΑgUg + ΣApUp + ΣΑfUf + ΣΙgΨg + ΣΙpΨp ΣΑg + Af + Ap
ACW
Area ratio of the facade module
Af , At, Am
Area ratio of the profiles
Ag
Area ratio of the glazing
Ap
Area ratio of the filling
Uf , Um, Ut
Thermal transmission coefficient of the profiles (windows, mullions, transoms)
Ug
Thermal transmission coefficient of the glazing
Up
Thermal transmission coefficient of the filling
Ψg, Ψp
Length-related heat transmission coefficient of the glazing or panel spacer
Ιg
Length of the visible glazing perimeter
Ιp
Length of the visible filling perimeter
Note: The visible surfaces Ag and/or Ap are the smaller of the surfaces visible from the two sides. The total of the length lg and/or Ip is the total of the visible glazing or filling perimeter. If different lengths are visible from the two viewing sides, the larger of the two has to be used.
www.balkan.gr
20
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Nominal values of the heat transmission coefficient Uf
W50
Nominal values of the heat transmission coefficient Uf Fixed cross-section
Mounting mullion
Mullion
Transom
Moving cross-sections Mullion with integrated sash, glazing bonded
The illustrated Uf values of the mullion-and-transom construction W 50 Were measured according to EN 12412-2 : 2009-07 and calculated according to EN 10077-2 : 2003-10 The allowance for the influence of the facade screws has already been taken into account. Screw Ă˜ 5,5 mm Spacing approx 250 mm
Insert cross-sections
April 2009 Apr
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
21
Mullion profiles, vertical (Level 3) 10
10 10 10
30
AE013-000002-00
AE013-929001-00
AE013-000003-00
( PK 392 )
( PK 390 )
( PK 391 )
14
20
26
37
10
AE013-000001-00
( PK 393 )
AE013-000004-00
50
50
10
7.1
7
2.5
11.5
7.1
10
11.5
7
2.5
Reinforcement AH550-5182100
63.5
80
87
83.5
100
107
Reinforcement AH550-5182080
46.4
46.4
AH550-5114084 AH550-5114080 Mullion profile
4,00 m delivery length
Dev. anod.: 416 mm Dev. mech.: 210 mm www.balkan.gr
4,00 m delivery length
6,00 m delivery length
AH550-5114104 AH550-5114100 Mullion profile
Weight: 1,85 kg/m
Dev. anod.: 456 mm
Weight: 2,05 kg/m
Dev. mech.: 250 mm
Ix cm4: 107,53
Ix
cm4:
62,76
6,00 m delivery length
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
22
Mullion profiles, vertical (Level 3) 900 94036
Mullion Level 3
900 94050
Einzelwerkzeug f r Stanzmaschinen
50,4
Matrizen und Stempel f r Stanzvorrichtung 900 94070
50 11,5
10
7.1
7
2.5
50 7.1
11.5
10
Reinforcement AH550-5182140
103.5
120
Reinforcement AH550-5182120
123.5
127
140
147
11.5
7
2.5
46.4
46.4
ΑΗ550-5114124 ΑΗ550-5114120 Mullion profile
4,00 m delivery length
Dev. anod.: 496 mm
Weight: 2,22 kg/m
Dev. mech.: 290 mm
Ix cm4: 167,14
6,00 m delivery length
ΑΗ550-5114140 Mullion profile Dev. anod.: 536 mm
Weight: 2,45 kg/m
Dev. mech.: 330 mm
Ix cm4: 243,04
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
23
Mullion profiles, vertical (Level 3)
50 10
7.1 2.5 7
50 7.1
11.5
10
11.5
7
2.5
143.4
160
167
162
180
187
Reinforcement AH550-5182160
45.8
ΑΗ550-5114160 Mullion profile
45
ΑΗ550-5114180 Mullion profile
(not permanently in stock)
Dev. anod.: 576 mm
Weight: 2,85 kg/m
Dev. anod.: 616 mm
Weight: 3,60 kg/m
Dev. mech.: 370 mm
Ix cm4: 352,81
Dev. mech.: 410 mm
Ix cm4: 553,02
www.balkan.gr
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
24
Mullion profiles, vertical (Level 3) 25
30
50 10
7.1 2.5
11.5
7
ΑΕ013-929036-20
ΑH550-5150015
180.8
200
207
ΑΗ550-5150053 W51 50053
Illustration shows clamped glazing
ΑΗ550-5115080 Mullion profile, vertical for sash installation
44.6
Dev. anod.: 384 mm
Weight: 1,53 kg/m
Dev. mech.: 95 mm
Ix cm4: 39,89
ΑΗ550-5114200 Mullion profile
(not permanently in stock)
Dev. anod.: 656 mm
Weight: 4,23 kg/m
Dev. mech.: 450 mm
Ix cm4: 790,30
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
25
Mullion profiles, vertical (Level 3) 25
25
PK 426 ΑΕ013-929036-20
PK 426 33
33
33
33
ΑΕ013-929036-20
7.1
7.1 2.5
11.5 120
ΑΗ550-5150053 W51 50053
200
160
11.5
7
7
2.5
ΑΗ550-5150053 W51 50053
4.5
4.5 66.5
95
55
160
66.5
15
Dies and punches for punching device 50,4
Illustration shows clamped glazing 11,5 Level 3
15
ΑΗ550-5115120
ΑΗ550-5115160
Mullion profile, vertical for sash installation
Mullion profile, vertical for sash installation
Dev. anod.: 464 mm
Weight: 1,93 kg/m
Dev. anod.: 544 mm
Weight: 2,32 kg/m
Dev. mech.: 135 mm
Ix cm4: 111,40
Dev. mech.: 270 mm
Ix cm4: 249,00
www.balkan.gr
26
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
Mullion corner profiles 90째, vertical (Level 3)
AH550-5113080 Mullion corner profiles 90o Dev. anod.: 632 mm
Weight: 2,85 kg/m
Dev. mech.: 160 mm
Ix cm4: 83,60
AE013-929001-01
St tube 60/60
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
27
Transom profiles, vertical (Level 1) The figures apply to a self-powered double punching machine No. 900 94070 Dies and punches for 900 94070 cutting out of the mullion profiles Dies and punches for 900 94070 cutting out of the mullion profiles = 94037
Mullion Level 3
Dies and punches for 900 94070 cutting out of the mullion profiles = 94038 900 94050 Punching tool for cutting out mullion, mounting mullion and transom profiles for use on HSP 110, Dyno 6, etc.
Transom Level 1
Transom Level 2
900 94036
50 10
7.1
16
6.1
7
2.5
AH550-5184046 T 902 00216
77
65.9
84
8,3
46.4
AH550-5121077 + (not permanently in stock) Transom profile for vertical application Dev. anod.: 354 mm
Weight: 1,645 kg/m
Dev. mech.: 254 mm
Ix cm4: 55,84
www.balkan.gr
50,
4
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
28
Transom profiles, horizontal (Level 2)
50 10
7.1 2.5
50 7.1
7
10
30.5
23.5
AH550-5184046
10.6
17.9
10.9
8.9
7
8.9
2.5
46.4
ΑΗ550-5122011 + (not permanently in stock) Transom profile for horizontal installation
ΑΗ550-5122024 Transom profile for horizontal installation
Dev. anod.: 252 mm
Dev. anod.: 276 mm
Weight: 1,06 kg/m
Dev. mech.: 97 mm
Ix cm4: 2,85
Dev. mech.: 72 mm
Weight: 0,69 kg/m Ix
cm4:
0,61
50 10
7.1 2.5
10
7
50 7.1
7
8.9
2.5
60.5
40.6
45.5
25.6
38.5
AH550-5184046 T 902 00202
53.5
8.9
AH550-5184046 T 902 00203
46.4
46.4
ΑΗ550-5122039 Transom profile for horizontal installation
ΑΗ550-5122054 Transom profile for horizontal installation
Dev. anod.: 306 mm
Dev. anod.: 336 mm
Weight: 1,36 kg/m
Dev. mech.: 157 mm
Ix cm4: 20,07
Dev. mech.: 127 mm
Weight: 1,20 kg/m Ix
cm4:
9,09
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
29
Transom profiles, horizontal (Level 2) AH550-5122080 Transom profile, horizontal for sash installation
30 W51 50059
ΑH550-5150053
Dev. anod.: 386 mm
Weight: 1,50 kg/m
Dev. mech.: 95 mm
Ix cm4: 41,10
4.5
15
PK 413
33
7
15
T-connector 902 00185 ΑH550-5184999 T-connector 902 00185 with drilling template 907 00027 with drilling template 907 00027
2.5
7.1
ΑΕ013-929036-20
80 120
50 10
7.1 2.5
50 7.1
8.9
10
2.5
8.9
T 902 00205 AH550-5184046
105.5
98.5
84.6
85.5
65.6
78.5
T 902 00204 AH550-5184046
46.4
46.4
AH550-5122079 Transom profile for horizontal installation
AH550-5122099 Transom profile for horizontal installation
Dev. anod.: 385 mm
Dev. anod.: 426 mm
Weight: 1,92 kg/m
Dev. mech.: 247 mm
Ix cm4: 101,07
Dev. mech.: 207 mm www.balkan.gr
Weight: 1,59 kg/m Ix
cm4:
50,74
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
30
Transom profiles, horizontal (Level 2) Max. glazing weight 150 kg per glazing support 75 kg
3
17
33
Glazing support AE011-903000-35 from profile AH550-5156042 Cut length 125 mm 50 10
7.1 2.5 7
50 7.1
8.9
10
2.5
8.9
7
T 902 00207
46.4
138.5
124.6
125.5
118.5
AH550-5184046
104.6
AH550-5184046
46.4
AH550-5122119 Transom profile for horizontal installation
AH550-5122139 Transom profile for horizontal installation
Dev. anod.: 466 mm
Dev. anod.: 506 mm
Weight: 2,30 kg/m
Dev. mech.: 327 mm
Ix cm4: 229,37
Dev. mech.:287 mm
145.5
T 902 00206
Weight: 2,12 kg/m Ix
cm4:
157,44
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
Transom profiles, horizontal (Level 2)
50 10
7.1
8.9
7
2.5
45.8
AH550-5122159 Transom profile for horizontal installation
www.balkan.gr
Dev. anod.: 546 mm
Weight: 2,74 kg/m
Dev. mech.: 367 mm
Ix cm4: 334,15
165.5
158.5
144.6
AH550-5184046 T 902 00208
31
32
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
Profiles AH550-5150015 Adapter frame profile for window sash 23.7
Adapter frame profile W51 50015 (C 35 anodised) and sash profile are screwed together after the paint treatment and assembled to form a common sash on which the glazing is then bonded by an authorised gas company.
Dev. anod.: 139 mm
Weight: 0,31 kg/m
(always C 35 anodised) 11.6
30
15
53
15
Drilling template 907 00023
42
Glazing support
AΕ001-901003-45
W51 50015
27
Corner connector AH900-TF558
5
14.5
PK 413 19.5
UV-resistant edge bonding always required
AF004-904000-75 904 00075
W51 22080
AH550-5150053 Sash profile for bonded glazing (flush surface with fixed glazing) Dev. anod.: 241 mm
Weight: 0,99 kg/m
Dev. mech.: 95 mm
Ix cm4: 13,72
AF004-904000-75
Corner connector AH900-TF558 AE001-901003-45
Drilling template 907 00023 Glazing support
AE013-929036-20
AH550-5122080
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
33
Profiles 50 35
15
AH550-5115080
Glazing bar, vertical above and below sash glazings Dev. anod.: 255 mm Dev. mech.: 115 mm
Weight: 1,060 kg/m Ix cm4: 22,26
7
80
Mullion W51 15080
AH550-5150080
2.5 6
7.1
7.1
2
Sash profile for bonded glazing
AH550-5150001 Glazing support profile for window sash (glued glazing) Dev. anod.: 54 mm
Weight: 0,178 kg/m
Dev. mech.: 0 mm Cut to length, 125 mm long = AE011-903000-31
15
Sash profile for bonded glazing
27
W51 50015
30
AH550-5156053 Glazing support profile for window sash (clamped glazing) Dev. anod.: 124 mm
Weight: 0,390 kg/m
Dev. mech.: 0 mm
Cut to length, 125 mm long = AE011-903000-33 7
AH550-5156042 Glazing support profile for fixed glazing horizontal half transom
16
26
Dev. anod.: 94 mm Cut to length, 125 mm long = AE011-903000-35
www.balkan.gr
Dev. mech.: 0 mm
Weight: 0,350 kg/m
34
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
Profiles
6
50
AH550-5051006 Pressure profile Dev. anod.: 155 mm
Weight: 0,538 kg/m
Dev. mech: 50 mm
12
50
AH550-5061012 Cover profile Dev. anod.: 147 mm
Weight: 0,240 kg/m
Dev. mech: 74 mm
10.5
49.3
AH550-5057010 Pressure profile Dev. anod.: 182 mm
Weight: 0,410 kg/m
Dev. mech: 0 mm
15
50
AH550-5061015 Cover profile Dev. anod.: 159 mm
Weight: 0,280 kg/m
Dev. mech: 80 mm
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
35
Profiles, pressure and cover profiles
97,7
50
AH550-5063098 acces. AE005-000001-00 Cover profile Dev. anod.: 293 mm
Weight: 1,340 kg/m
Dev. mech: 206 mm
50
20
30
50
AH550-5061020 Cover profile Dev. anod.: 177 mm Dev. mech: 90 mm
www.balkan.gr
AH550-5067030 Pressure profile + not permanently in stock Weight: 0,301 kg/m
Dev. anod.: 248 mm Dev. mech: 155 mm
Weight: 0,880 kg/m
36
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
Frame inserts, Series RG block windows for facade
AH275-5075027 AH275-5075027 Frame inserts for for Series RG 75 Frame inserts Dev.Series anod.: 474 RG /75 Weight: 1,734 k 354* mm Dev. anod.: 474 / 354* mm Dev. mech.: 104mm Dev. mech.: 104mm
AH900TF495
Weight: 1,734 kg/m
AH900-TF483 Drilling template 907 00347 Processing, see Series RGÎ’ block windows
Installation situation in facade W50
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
37
Frame inserts, Series RG 75 facade 73.5 19.5
30
24
4
AH275-5075030 Frame inserts for Series RG 75 E/P 901 569 AE001901569-00
10
Dev. anod.: 474 / 339* mm Weight: 1,871 kg/m
70.5 28
75
38.5
Dev. mech.: 85mm
8.5
4.5
E 901 458 AE001P 901 459 901459-00
16.5
Drilling template 907 229 Processing, see Series RG 75
56 72.5
904 495
904 115
RG 1210
904 285
AH550-5075030 W50 75030
50
www.balkan.gr
105.5
38
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Accessories
W50
Frame inserts, Series W50 facade 15
43.1
AH550-5150003 Frame inserts for flap window Dev. anod.: 407 mm
Weight: 1,488 kg/m
22.4
75
Dev. mech.: 43 mm
11.3
50
44.8
Installation situation in facade W50
60.4
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
39
Window inserts, Series W50 facade 11.5
6
11.8
AH275-280 Dev. anod.: 384 mm
Weight: 1,681 kg/m
Dev. mech.: 92 mm
Ix cm4: 10,51
25
26
57
64
Sash inserts for flap window
28.7
19.5
50
www.balkan.gr
Installation situation in facade W50
60.4
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
40
Auxiliary and connecting profiles
12.1
12.1 7.1
8
10
3.5 8.5
7.1
20
AH550-9071008
AH550-9071010
AH550-5150001 Glass support for flap window (standard cw)
Spacer profile 8mm
Spacer profile 10mm
Dev. anod.: 69 mm
Dev. anod.: 77 mm
Dev. anod.: 54 mm
Dev. mech.: 16 mm
Dev. mech.: 20 mm
Dev. mech.: 0 mm
Weight: 0,120 kg/m
Weight: 0,150 kg/m
Weight: 0,178 kg/m
24.7
7.7
19.8
20
20
16
10,7
10
25,3
38
AH550-902
AH550-903
Joint for glass structural
Spacer for glass structural
Spacer for glass structural
Dev. anod.: 119 mm
Dev. anod.: 114 mm
Dev. anod.: 97 mm
Dev. mech.: 0 mm
Dev. mech.: 0 mm
Dev. mech.: 0 mm
Weight: 0,795 kg/m
Weight: 0,348 kg/m
Weight: 0,656 kg/m
14.7
23.2
3.5
AH550-901
AH550-5150002 Glass support for flap window (structural cw) Dev. anod.: 83 mm Dev. mech.: 0 mm
20
Weight: 0,261 kg/m
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
41
29.5
44
.1
Variable angle profiles
50.0
AH550-5113001
AH550-5113002
Column addition for variable corner
Pressure plate addition for 45o
Dev. anod.: 404,4 mm
Weight: 1,228 kg/m
Dev. mech.: 80,3 mm
Dev. anod.: 255,7 mm
Weight: 0,794 kg/m
Dev. mech.: 77 mm
.4
34
AH550-5113003
AH550-5113004
Pressure plate addition for Dev. anod.: 217,5 mm
Pressure plate addition for 150o
60o
Weight: 0,665 kg/m
Dev. mech.: 57,6 mm
www.balkan.gr
Weight: 1,013 kg/m
AH550-5113006
Cover for pressure plate addition for Dev. mech.: 29 mm
353,7 mm
Dev. mech.: 81 mm
AH550-5113005 Dev. anod.: 104 mm
Dev. anod.:
150o
Weight: 0,163 kg/m
Column addition for for 150o Dev. anod.:
83,4 mm
Dev. mech.: 11,3 mm
Weight: 0,203 kg/m
42
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
Profiles for accessory parts
44.8
AH550-5182160 Profile for reinforcement 902 00230 in mullion profile AH550-5114160 Weight: 3,20 kg/m
AH550-5182140 Profile for reinforcement 902 00229 in mullion profile AH550-5114140
45.2
45.2
Weight: 2,85 kg/m
142.7
45.2
122.7
AH550-5182120 Profile for reinforcement 902 00228 in mullion profile AH550-5114120
102.7
Weight: 2,52 kg/m
62.7
82.7
AH550-5182100 Profile for reinforcement 902 00227 in mullion profile AH550-5114100 Weight: 2,23 kg/m
AH550-5182080 Profile for reinforcement 902 00226 in mullion profile AH550-5114080 Weight: 1,88 kg/m 45.2
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
43
Profiles for accessory parts
44
161,2
180
44,4
44,4
44
AH550-5182180 Profile for reinforcement in mullion profile AH550-5114180 Weight: 3,921 kg/m
www.balkan.gr
AH550-5182200 Profile for reinforcement in mullion profile AH550-5114200 Weight: 4,317 kg/m
44
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
Profiles for accessory parts
53,1
R18.9
45.8
64,5
10
29
AH550-5184999
AH550-5184346
T-Connector for transom AH550-5122080
T-connector profile, variable for transom AH550-5122039 - AH550-5122139 for production of inclined transoms
Weight: 2,56 kg/m
Weight: 1,562 kg/m
AE003-000001-00 Fast connector / transom Dev. anod.: 268 mm Dimension: 40mm
AH550-5184002 Fast connector / mullion Dev. anod.: 98 mm
Weight: 0,518 kg/m
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
45
Profiles for accessory parts
AH550-5184046 T-Connector for transom AH550-5122039 - AH550-5122139 Dev. anod.: 217 mm
AH550-5184045 T-Connector for transoms AH550-5122159 Dev. anod.: 215 mm
Weight: 1,574 kg/m
Weight: 1,598 kg/m
AH550-5184044 T-Connector for transoms AH550-5122199
AH550-5184001 Fast connector / transom
Dev. anod.: 214 mm
Dev. anod.: 193 mm
www.balkan.gr
Weight: 1,561 kg/m
Weight: 1,307 kg/m
46
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Profiles
W50
Profiles for accessory parts
44
AH550-5182000 28
Mounting accessory for W50
150
Weight: 10,357 kg/m
68 32
8
32
180
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Accessories
W50
47
Accessories
903 271
10 3
Joint sealing tape 10 x 3 mm Roll 10 m – impregnated
W51 5001
20
Glazing support for sash with clamped glazing 125 mm long (from profile W51 56039)
903 00033
39
Glazing support for sash with bonded glazing 125 mm long (from profile W51 56053) 885276
903 00035
39.6
Glazing support for fixed glazing 125 mm long (from profile W51 56042) 884454
903 00040
0.6
12
38
0.6
Butyl adhesive tape Roll 30 mm – double-sided
903 00041
Butyl adhesive tape Roll 10 mm - for the roof area
Connecting foil Width 1
5±0
Keder 7.5
Waterstrip
SG tan EPDM sealing strips to DIN 7864 as facade gasket For sealing between facade elements and inner supporting structure (not water vapour-tight) 904 855 Sealing strip. EPDM 150 mm wide with weatherstrip 20 m on roll 904 857 Sealing strip. EPDM 250 mm wide with weatherstrip 20 m on roll 904 859 Sealing strip. EPDM 300 mm wide with weatherstrip 20 m on roll 904 861 Sealing strip. EPDM 330 mm wide with weatherstrip 20 m on roll 904 864 Sealing strip. EPDM 500 mm wide with weatherstrip 20 m on roll 905 429
SG adhesive FA for EPDM sealing strips Required adhesion surface width 80- 100 mm Adhesive consumption 90 -110g (= approx. 0.08-0.10 ltr.) per running metre Tubular plastic bag (standard tubes) of 0.6 ltr (approx. 700 g) 905 436 SG cleanser T for soiled surfaces (grease) Container with (approx. 850 g) CAUTION! During adhesion, the instructions and hazard warnings of the manufacturer must be strictly observed! www.balkan.gr
48
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Glass thickness chart
W50
Glass thickness
Insulator
Rabbed width
Inner gasket
Outer gasket
Torx screw
12 mm 14 mm 16 mm
PK 391 PK 391 PK 391
25 mm 25 mm 25 mm
904 00035 = 9 mm 904 00030 = 7 mm 904 00025 = 5 mm
904 00315 = 4 mm 904 00315 = 4 mm 904 00315 = 4 mm
906 900 = 35 mm 906 900 = 35 mm 906 900 = 35 mm
18 mm
PK 391
25 mm
904 00020 = 3 mm
904 00315 = 4 mm
906 900 = 35 mm
18 mm
PK 393
31 mm
904 00035 = 9 mm
904 00315 = 4 mm
906 902 = 45 mm
20 mm
PK 393
31 mm
904 00030 = 7 mm
904 00315 = 4 mm
906 902 = 45 mm
22 mm
PK 393
31 mm
904 00025 = 5 mm
904 00315 = 4 mm
906 902 = 45 mm
24 mm
PK 393
31 mm
904 00020 = 3 mm
904 00315 = 4 mm
906 902 = 45 mm
24 mm
PK 392
37 mm
904 00035 = 9 mm
904 00315 = 4 mm
906 901 = 50 mm
26 mm
PK 392
37 mm
904 00030 = 7 mm
904 00315 = 4 mm
906 901 = 50 mm
28 mm
PK 392
37 mm
904 00025 = 5 mm
904 00315 = 4 mm
906 901 = 50 mm
30 mm
PK 392
37 mm
904 00020 = 3 mm
904 00315 = 4 mm
906 901 = 50 mm
28 mm
PK 390
41 mm
904 00035 = 9 mm
904 00315 = 4 mm
906 903 = 55 mm
30 mm
PK 390
41 mm
904 00030 = 7 mm
904 00315 = 4 mm
906 903 = 55 mm
32 mm
PK 390
41 mm
904 00025 = 5 mm
904 00315 = 4 mm
906 903 = 55 mm
34 mm
PK 390
41 mm
904 00020 = 3 mm
904 00315 = 4 mm
906 903 = 55 mm
904 00040 14
904 00035 9
904 00030 7
904 00025 5
904 00020 3
904 00315 4
Rabbet dimensions
CAUTION! When using sealing washers, observe the screw length and the new screw insertion depth!! Glass thickness charts for sashes, please refer to the respective series for the sash used.
Mullion drawn rotated through 90째
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Seals
W50
24.5
49
24,5
4.8
4,8
5
5
3
AE004-904015-00 904 015
Stop gasket EPDM, black
AE004-000002-00 Gasket for structural flap window
AE004-000003-00 Gasket for standard flap window
EPDM, black
EPDM, black 5.9
5.8 4
2,6
19.7
5,3
7
20.6
AE004-904001-00 904 520
Gasket, gasket external Central Silicone, grey EPDM, black
AA205-101-00 904 540 Gasket, Gasket external for flap window
EPDM, black
EPDM, black 10째
asymmetric
12
Glazing max. 10째 angle
7
4
7
10 째
7
14
AE004-000001-00 Sealing cord Gasket for structural W50 EPDM, black
7 asymmetric
AE004-904000-40 904 00040
12
Glazing max. 10째 angle
AE004-904945-00 904 945
Gasket, internal
AE004-904940-00 904 940 Gasket, external
EPDM, black
EPDM, black
EPDM, black
3
Gasket, internal
904 00020 AE004-904000-20
7
7
7
7
5
AE004-000-30 904 00030
Gasket, internal
AE004-904000-25 904 00025 Gasket, internal
EPDM, black
EPDM, black
EPDM, black
Gasket, internal 4
9
7
4
AE004-904000-35 904 00035
Gasket, internal
AE004-904000-75 904 00075 Gasket, internal
AE004-904003-15 904 00315 Gasket, external
EPDM, black
EPDM, black
EPDM, black
www.balkan.gr
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Screws
W50
50
Screws of stainless steel
AE010-906116-00
AE010-906270-00
AE010-906609-00
Countersunk screw
Countersunk screw
Roof window hinges
for connecting pin
for Τ-joints
AE010-906752-00
AE010-906759-00
AE010-906761-00
Fillister-head self-tapping screw
Countersunk self-tapping screw
Countersunk self-tapping screw
with cross head
with cross head
with cross head
25
Cylinder screw
n3.5
AE010-000006-00 Fillister-head self-tapping screw B3,5X25 with cross head
AE010-906762-00 Fillister-head self-tapping screw B4.2X25 with cross head
AE010-000004-00 Countersunk self-tapping screw B4.8X25 with cross head
AE010-906770-00 Fillister-head self-tapping screw B4.8X32 with cross head
AE010-906777-00
AE010-906779-00
AE010-906782-00
Self-tapping screw
Fillister-head self-tapping screw
Countersunk self-tapping screw
with cross head
with cross head
with cross head April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Screws
W50
51
Ø DIN 7982 ISO 7050
AE010-000005-00 906 900
Countersunk self-tapping screw B 4,8 x 9,5 with cross head
FWB facade screw Torx T25, with special thread Ø 5,5x35mm
Sealing washer with rubber coat (EPDM) for screw Ø 4,8 for pressure profiles
60
906 797
AE010-000001-00
AE010-906901-00 906 901
AE010-000002-00
AE010-000003-00
FWB facade screw Torx T25, with special thread Ø 5,5x45mm
FWB facade screw Torx T25, with special thread Ø 5,5x50mm
FWB facade screw Torx T25, with special thread Ø 5,5x55mm
FWB facade screw Torx T25, with special thread Ø 5,5x60mm
AE009-905150-00 905 150
AE009-905160-00 905 160
Roll pin, AI for corner joints
Roll pin, AI for T-joints
Accessories
905 561 Connecting pin for the connection with slide pieces
www.balkan.gr
52
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Screws
Accessories
AE005-000001-00 AE005-000001-00 Plug decorative for AH550-5063098
AE005-000005-02 Fold ventilation black, for W50 Cut when use insulator or AE013-000001-00 Cut?when?use?insulator?AE013-000001-00 Cut when use insulator or AE013-000002-00 Cut?when?use?insulator?AE013-000002-00
Fill with silicone Fill?with?silicone
AE005-000006-02
Fill with silicone Fill?with?silicone
Seal piece for dilatation W50 Use screw AE010-906777-00 Use?screw?AE010-906777-00
AE013-000006-00 18
Square tube
24
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Accessories
W50
53
Accessories AE013-929001-00 (PK 390) Insulator profile 30 mm Plastic
26 Rabbet dimensions
AE013-000002-00 (PK 392) Insulator profile 26 mm Plastic 22 Rabbet dimensions
AE013-000001-00 (PK 393) Insulator profile 20 mm Plastic 16 Rabbet dimensions
AE013-000003-00 (PK 391) Insulator profile 14 mm Plastic 10
8
20
AE011-929790-00 (PK 79) T-profile for sealing elements
12
Plastic
901 00520
33
In sash area with clamped glazings, sash profile W 51 50053
www.balkan.gr
AE013-929036-20 (PK 426) Insulating and supporting profile Plastic
54
W50
Curtain Wall system for fa ades and roofs Thermal-insulated building construction Series W 50 Corner connector
Corner connectors for flap window
Β Corner connector
A
A. AE001-000003-00 B. ΑΑ001-022-00
for profile
AH550-5150003
Connection with 5g adhesive 905 405 press
AT038-015-00
Corner connector
AE001-000004-00 for profile
AH275-280
Connection with 5g adhesive 905 405 Press
AT038-015-00
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Corner connectors
W50
55
Corner connector Profiles
Roll pin
Roll pin
905 160
905 140 18
Profile W50 75030 W50 60030 W50 75030
Corner connector 901 569
8,5 60,2 7
for profile W50 75030
5 4
Connection with 2 roll pins 905 160 and 5g adhesive 905 405
901 569 60
with drilling template 907 229 and drilling template 907 00469
Corner connector 901 458 for profile W50 75030
With drilling templates 907 229 and 907 00469
Connection with 2 roll pins 905 140 and 2g adhesive 905 405 with drilling template 907 229 and drilling template 907 00469 Pressta corner connector 901 459 for profile W50 75030
901 458 for pinning 901 459
Connection with 2g adhesive 905 405
Corner connector for roof window The corner connectors No.: 901 595 / 605 / 635 / 645 are illustrated with the corresponding profiles.
Corner connector 901 00245 n4
Profiles Profil
n7 Roll pin
for profile W50 75027 Roll pin 905 150
905 140
W50 75027 5,2
Connection with 2 roll pins 905 150 and 5g adhesive 905 405 Drilling template 907 00347
8,3
Corner connector 901 00250 for profile W50 75027 Connection with 2roll pins 905 140 and 2g adhesive 905 405 Drilling template 907 00347
901 00250 pinning 901 00251
901 911
Alternatively: Pressta corner connector 901 00251 for profile W50 75027
With drilling templates 907 00347 901 00245
www.balkan.gr
Reinforcement angle bracket 901 911 for profile W50 75027 Connection with 5g adhesive 905 405
56
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Corner connector
Corner connector sash W51 50053 (using roll pin) Drilling template
The corner connector must be installed with adhesive 905 405 The cut surfaces must be sealed. Cutting length 45,4 mm
Drilling template Sash cutting dimension = Distance between centres + 1 mm
Reinforcement angle bracket of TF 481 in the corner area of insulating profile PK 426 Article No. 901 00520
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
57
T-connection half transom to half mullion T-connector
Drilling template
Transom axis
Transom profile
T-connector Mullion profile
Transom contour drawn rotated through 90째 for illustration of the line course
Mullion profile
Distance between centres
Drilling template
Countersink bores
Transom profile
T-connector Distance between centres Transom cutting dimension = Distance between centres +20mm If necessary: Tapered roll pin ISO 8745-5x20-St (stainless steel)
www.balkan.gr
58
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
Cutting point, mullion corner, vertical with 190째, symmetrical Glazing bar
T-connector
Transom profile
Drilling template
Glazing bar
Mullion profile
T-connector
If necessary: Tapered roll pin ISO 87455x20-St (stainless steel)
Transom contour drawn rotated through 90째 for illustration of the line course
Transom contour drawn rotated through 90째 for illustration of the line course
Mullion profile
Transom profile
T-connector
Drilling template
Distance between centres Transom cutting dimension = Distance between centres +20mm
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
59
T-connection transom to mullion Schematic view Further details on the following pages of the catalogue
T-connector
Transom contour drawn rotated through 90째 for illustration of the line course
Mullion profile
T-connector
Drilling template
Transom profile
Transom cutting dimension = Distance between centres - 18mm Distance between centres
www.balkan.gr
60
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
T-connection with T-connector T-connection – schematic view
T-connection with T-connector
Butyl adhesive tape 12 x 50 mm from Article No. 903 00040
Vertical load per T-connector max. 75 kg Transom chamber
Drilling templates for transom end No. 907 00106 for mullion holes No. 907 00106 for T-connector to mullion No. 901 00101 Punching machine 900 94070 with die and punch for mullion No. 900 94036
Cut to length T-connector
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
61
T-connection transom (Level 2) to mullion (Level 3)
Mullion, vertical Level 3
Mullion, vertical Level 3
Transom, Level 2
Butyl adhesive tape of 903 00040
Transom, Level 2
Pu n too chin l 90 g m 0 9 ach 403 ine 6 90
Butyl adhesive tape of 903 00040
09
www.balkan.gr
407
0w
ith
Transom, horizontal Level 2
62
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
T-connection transom (Level 2) to mullion (Level 3)
904 00040
Scale 1:2
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
T-connection transom (Level 2) to mullion (Level 3)
W90 71010
Scale 1:2
www.balkan.gr
W50
63
64
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
T-connection transom (Level 2) to mullion (Level 3) Mullion
902 00202
of profile
T-connector Transom W51 22039 to mullion W51 14 *** Connection with 2 roll pins 905 160 2 screws 906 752 5 g adhesive 905 405 Drilling template 907 00106 Bores in horizontal transom for screws and roll pins Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
Mullion, Level 3
Mullion
902 00203 of profile
Transom, Level 2
T-connector Transom W51 22054 to mullion W51 14 ** Connection with 2 roll pins 905 160 2 screws 906 752 5g adhesive 905 405 Drilling template 907 00106 Bores in horizontal transom for screws and roll pins Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
65
T-connection transom (Level 2) to mullion (Level 3)
902 00204 T-connector Transom W51 22079 to mullion W51 14080 Connection with 2 roll pins 905 160 2 screws 906 752 10g adhesive 905 405 Drilling template 907 00106 Bores in horizontal transom for screws and roll pins
Mullion
Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical
of profile
Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
Transom
902 00207 T-connector Transom W51 22099 to mullion W51 14100 Connection with 2 roll pins 905 160 2 screws 906 752 15g adhesive 905 405 Drilling template 907 00106 Bores in horizontal transom for screws and roll pins Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors
Mullion
Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
of profile
Transom www.balkan.gr
66
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
T-connection transom (Level 2) to mullion (Level 3)
902 00206 T-connector Transom W51 22119 to mullion W51 14120 Connection with 2 roll pins 905 160 2 screws 906 752 20 g adhesive 905 405 Drilling template 907 00106 Bores in horizontal transom for screws and roll pins
Mullion
of profile
Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
Transom
902 00207 T-connector Transom W51 22139 to mullion W51 14140 Connection with 2 roll pins 905 160 2 screws 906 752 20 g adhesive 905 405 Drilling template 907 00106 Bores in horizontal transom for screws and roll pins Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors
Mullion
31.0335.08
Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
of profile
Transom April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
67
T-connection transom (Level 2) to mullion (Level 3)
902 00208 T-connector Transom W51 22159 to mullion W51 14160 Connection with 2 roll pins 905 160 2 screws 906 752 30 g adhesive 905 405 Drilling template 907 00106 Bores in horizontal transom for screws and roll pins Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical
Mullion
Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
of profile
Transom
902 00209 T-connector Transom W51 22179 to mullion W51 14180 Connection with 2 roll pins 905 160 2 screws 906 752 35 g adhesive 905 405 Drilling template 907 00106 Bores in horizontal transom for screws and roll pins
Mullion
31.0335.09
Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical
of profile
Transom
www.balkan.gr
Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
68
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
T-connection transom (Level 2) to mullion (Level 3) Mullion T-connector Transom W51 22* to mullion W51 14*
of profile W51 84046
Connection with 2 roll pins 905 160 1 screws 906 752 35 g adhesive 905 405 Drilling template 90700106 Bores in horizontal transom for screws and roll pins Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile 52
50,4
Transom
37,8
Mullion Level 3
T-connector Transom W51 22* to mullion W51 14* 36
Mullion Pfosten
Connection with 2 roll pins 905 160 2 screws 906 752 35 g adhesive 905 405
16
Transom Level 2 of profile W51 84046
Drilling template 90700106 Bores in horizontal transom for screws and roll pins Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
69
T-connection transom (Level 1) to transom (Level 2) Transom (1)
T-connector of profile W51 84046
902 00216 T-connector Transom W 51 21077 to transom W 51 22079
5 65,
15,6 36
8,3
Connection with 2 roll pins 905 160 2 screws 906 752 10 g adhesive 905 405 Drilling template 907 00106 Bores in vertical transom for screws and roll pins
13,7
Transom (2) Drilling template 907 00101 Bores in horizontal transom for attachment of the T-connectors
50. 4
Lower recess only if the vertical transom is continued
Transom, horizontal Punching machine 900 94070 with die and knife 900 94037 Punch-out on horizontal transom
Transom W51 21077 vertical 36
902 00216
T-connector of profile W51 84046
50,4
36
65,5
15,6
4,5
Transom W51 22079 horizontal
8,3
13,7
Transom (2)
www.balkan.gr
70
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
Rapid Connection AE005-000002-02 Plug transom cover
AH
550
-22
039 AH
550
-22
059 AH
550
-22
079
AE005-000003-02 Plug transom cover
AH
550
-22
AE005-000003-02
099 AH
550
-22
1
119 AH
550
-22
139 AH
550
-22
159
AH550-5184002-00
2 AH550-5184001-00
4
3
AE010-000006-00 April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
71
Rapid Connection
W51 84001 W51 84002
17.1
T-connector Transom W51 22119 to mullion W51 14***
76 10.9
104
11.5
Connection with 2 screws 906 754 4 screws 906 761 1 plug transom cover AE005-000003-02 10 g adhesive 905 405 Drilling template 907 00106 Bores in vertical transom for screws and roll pins Drilling template 907 00101 Bores in horizontal transom for attachment of the T-connectors Transom, horizontal Punching machine 900 94070 with die and knife 900 94037 Punch-out on horizontal transom
43 10
37.8
50.4
Mullion Level 3
20.5
Transom Level 2
6
66. 31.8 .9 10 10.9
10
6
94.
(with profile W90 71010) T-connector Transom W51 22119 to mullion W51 14***
22,5 17,1
W51 84001 W51 84002
Connection with 2 screws 906 754 4 screws 906 761 1 plug transom cover AE005-000003-02 10 g adhesive 905 405 Drilling template 907 00106 Bores in vertical transom for screws and roll pins Drilling template 907 00101 Bores in horizontal transom for attachment of the T-connectors Transom, horizontal Punching machine 900 94070 with die and knife 900 94037 Punch-out on horizontal transom
www.balkan.gr
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
72
T-connection transom (Level 2) to mullion (Level 3)
11.1
W51 84001 W51 84002
27
65.2
50.4
T-connector Transom W51 22079 to mullion W51 14080
22
36
Connection with 2 screws 906 761 4 screws 906 777 1 plug transom cover AE005-000002-02
18.3
Drilling template 90700106 Bores in horizontal transom for screws and roll pins
Mullion W51 14080
Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors W51 84002
Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036
W51 84001
Punch-out on mullion profile Transom W51 22079
W51 84001 W51 84002 11.
27
50.4
84.2
22
56
T-connector Transom W51 22099 to mullion W51 14100 Connection with 2 screws 906 761 4 screws 906 777 1 plug transom cover AE005-000003-02
17.3
Drilling template 90700106 Bores in horizontal transom for screws and roll pins Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors
Mullion W51 14100
W51 84002 W51 84001
Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
Transom W51 22099
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
73
T-connection transom (Level 2) to mullion (Level 3)
11.1
27
22
76
W51 84001 W51 84002 T-connector Transom W51 22119 to mullion W51 14120
50.4
104,0
Connection with 2 screws 906 761 4 screws 906 777 1 plug transom cover AE005-000003-02
17.1
Drilling template 90700106 Bores in horizontal transom for screws and roll pins
Mullion W51 14120
Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036
W51 84002 W51 84001
Punch-out on mullion profile Transom W51 22119
11.
27
50.4
124,0
22
96
W51 84001 W51 84002 T-connector Transom W51 22139 to mullion W51 14140 Connection with 2 screws 906 761 4 screws 906 777 1 plug transom cover AE005-000003-02
17.1
Drilling template 90700106 Bores in horizontal transom for screws and roll pins
Mullion W51 14140
Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors W51 84002 W51 84001
Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
Transom W51 22139
www.balkan.gr
74
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 T-connection
W50
T-connection transom (Level 2) to mullion (Level 3)
11.1
27
22
116
W51 84001 W51 84002 T-connector Transom W51 2259 to mullion W51 14160
50.4
144,0
Connection with 2 screws 906 761 4 screws 906 777 1 plug transom cover AE005-000002-02
17.1
Drilling template 90700106 Bores in horizontal transom for screws and roll pins
Mullion W51 14160
Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors W51 84002
Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036
W51 84001
Punch-out on mullion profile Transom W51 22159
11.6
27
162,5
W51 84001 W51 84002
50.4
T-connector Transom W51 22179 to mullion W51 14180
22
136
Connection with 2 screws 906 761 4 screws 906 777 1 plug transom cover AE005-000003-02
16.1
Drilling template 90700106 Bores in horizontal transom for screws and roll pins Mullion W51 14180
Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors
W51 84002 W51 84001
Mullion profile, vertical Punching machine 900 94070 with die and knife 900 94036 Punch-out on mullion profile
Transom W51 22179
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Reinforcement
W50
Reinforcement, vertical butt joint mullion/mullion 902 00226 Reinforcement for mullion W 51 14080 Length 300 mm as bar 6,0 m long No.: W51 82080
Reinforcement Number and spacing of the bolts according to statics requirements
902 00227
Joint
300
Reinforcement for mullion W 51 14100 Length 300 mm as bar 6,0 m long No.: W51 82100
902 00228 Reinforcement for mullion W 51 14120 Length 300 mm as bar 6,0 m long No.: W51 82120
902 00229 Reinforcement for mullion W 51 14140 Length 300 mm as bar 6,0 m long No.: W51 82140
905 561 4
25
M. 1:1 www.balkan.gr
Shown in reduced size
906 270
906 830
902 00230
Reinforcement for mullion W 51 14160 Length 300 mm as bar 6,0 m long No.: W51 82160
75
76
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Variable T-connection
•
Variable T-connection, transom (Level 2) to mullion (Level 3)
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Variable T-connection
W50
77
Tr a
ns om
Variable T-connection, transom (Level 2) to mullion (Level 3)
902 00264 T-connector, variable Transom W51 22079 to mullion W51 14080 Connection with 3 roll pins 906 770 1 screws 906 901 10 g adhesive 905 405
Mullion
Transom
Insulator PK 390
Insulator PK 390
Bores in the inclined transom for screws according to the angle Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors
Transom (level 2)
Tr an s
om
Mullion (level 3)
902 00265 T-connector, variable Transom W51 22099 to mullion W51 14100
Insulator PK 390
Transom (level 2)
Mullion (level 3)
www.balkan.gr
Connection with 3 roll pins 906 770 1 screws 906 901 15 g adhesive 905 405
Mullion
Transom
Insulator PK 390
Bores in the inclined transom for screws according to the angle Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connectors
78
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Variable T-connection
Tr a
ns om
Variable T-connection, transom (level 2) to mullion (level 3)
902 00266
Transom
Mullion
T-connector, variable Transom W51 22119 To mullion W51 14120 Connection with: 3 screws 906 770 1 screw 906 901 20 g adhesive 905 405
Insulator PK 390
Insulator PK 390
Bores in the inclined transom for screws according to the angle Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connector
Transom (level 2)
Tr a
ns o
m
Mullion (level 3)
902 00267 T-connector, variable Transom W51 22119 To mullion W51 14120
Insulator PK 390
Transom (level 2)
Connection with: 3 screws 906 770 1 screw 906 901 25 g adhesive 905 405
Mullion
Transom
Insulator PK 390
Bores in the inclined transom for screws according to the angle Drilling template 907 00101 Bores in vertical mullion for attachment of the T-connector
Mullion (level 3)
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Drilling template
W50
79
Drilling template 907 00101 - Schematic view Positioning of the template on the mullion profile
Mullion profile Level 2
www.balkan.gr
Positioning of the template on the disengaged mullion profile
Mullion profile Level 2
80
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Drilling template
Drilling template 907 00101 - Schematic view Positioning of the template on the disengaged mullion profile (2)
Positioning of the template on the mullion profile (2)
Mullion profile Level 2
Mullion profile Level 2
Shim
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Τ-connection
W50
81
T-connection transom / half-mullion to half mullion 30
5.2
39.5
37.3
T-connector 902 00185
906 609
Drilling template
907 00027
In order to illustrate the course of the line, the profiles are drawn rotated through 90°
T-connector 902 00186
Drilling template
www.balkan.gr
43.5 37.9
Transom profiles Riegelprofile
907 00028
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
82
Cutting point, horizontal - cutting of transom W51 22080
Tra n
som
axi
Ax
is o
f th
Mullion W51 15080 vertical
s
eb
ore
Glazing transom W51 50080 vertical above and below sash panels
80
20
2 51
W som tal n Tra izon r Ho
Glazing transom W51 50080 vertical above and below sash panels
Cutting allowance
Mullion W51 15080 vertical
T-connector 902 00185
In order to illustrate the course of the line, the profiles are drawn rotated through 90o
Mullion W51 15080 vertical
Transom W51 22080 Horizontal
Cutting allowance = Matrix dimension + 20 mm April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Installation of insulator
W50
83
Installation of insulator PK 426 in sash area (clamped glazing) Transom
Transom
Corner connector 901 00520 from profile TF 481
Axis
g
hin
tc No Axis
Notchings in the horizontal parts PK 426 www.balkan.gr
84
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting to length
W50
Cut lengths
Axis (A)
Axis (A)
Cut lengths (L)
Cover profile
L = A - 52 mm
1
.
1
Cover profile
L = A - 60 mm
5
5
.
Insulator profile + transom profile .
L = A - 18 mm 25
W50 61015
25
.
L = A - 18 mm
Transom profile
904 00030 Transom profile
PK 390
904 00040
Insulator profile . L = A - 18 mm
. L = A - 60 mm W50 57008
9
Axis (A) PK 390
25
Pressure profile
Axis (A) Pressure profile
Axis (A) 9
25
25
Mullion
16
1
5
Cover profile
Cover profile . L = A - 52 mm
W50 61020
W50 57008
PK 390
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Facade connections
W50
85
Facade connections Schematic representation of various possibilities
www.balkan.gr
Movable bearing
Movable bearing
Movable bearing
Fixed bearing
Fixed bearing
Fixed bearing
Movable bearing
Movable bearing
Movable bearing
Fixed bearing
Fixed bearing
Fixed bearing
86
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
Overview of cutting points
Mullion, level 3
between the horizontal transoms, level 2
Transom, level 1
Mullion, level 3
Continuous Level 2 transom
Continuous Level 2 transom
Mullion, level 3
Mullion, level 3
Transom Level 2
Mullion
Mullion, vertical Level 3
Transom, horizontal Level 2
Transom, vertical Level 1
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, mullion, vertical (Level 3) Further mullion profiles up to 200 mm installation depth, see profile illustrations
Transom
Transom
Transom
Transom
Transom
Transom
Further glazing thicknesses, see Glazing thickness chart
www.balkan.gr
W50
87
88
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, mullion corner, vertical with 160째, symmetrical
Transom
Transom contour drawn rotated through 90째 for illustration of the line course
CAUTION! Due to the excessive angle of the glazings, the vertical pressure profiles may only be tightened until they fulfil their sealing function and not too tightly. April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
89
Cutting point, mullion corner, vertical with 190째, symmetrical
Transom contour drawn rotated through 90째 for illustration of the line course
Transom
CAUTION! Due to the excessive angle of the glazings, the vertical pressure profiles may only be tightened until they fulfil their sealing function and not too tightly.
www.balkan.gr
90
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, transom, horizontal (Level 2)
Drainage of the transom The transom is drained via at least 2 bores (dia. 6 mm) or slots 20x5 drilled in the retaining profile and cover strip
Distance max. 600 mm
Distance between centres
Further glazing thicknesses, see Glazing thickness chart
Glazing support Nr. 903 00035
Transom drainage At least 2 holes ÎŚ6 mm or slots 20x5 mm
Further transom profiles in steps of 20 mm up to an installation depth of 198.5 mm - see profile illustrations
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
91
97,6
Cutting point, vertical, sashes with bonded glazings
AH550-5063098
35
4
80
AH275-280
2
64
9
28
204,6
W50 57010
8
AH550-5150003
17,3
43,1
50 110,4
www.balkan.gr
W5114080
50
W50 57010
15 34
904 00100 50
15
15
122
904 00075
PK 426
904 00100 11
W50 61015
904 00315
904 00030
W51 22079
Riegel Transom
26
PK 426 15
W50 61020
W51 15080
19.5
37
904 00075
30
5
The glazing planes in the window sash and in the fixed panel are flush
W51 50015
W51 50053
27
4.5
7
15
W51 22080
Riegel Transom
42
78.5
11
W50 57010
904 00315
W51 50015
W51 50053
15
CAUTION! Min. grid dimension = 750mm
W51 22080
Riegel Transom
Sash size = Grid dimension + 1mm Fl gelzuschnitt = Rasterma + 1 mm
53
W50 61020
27
42
66.5 1.5
W50 61015
W51 15080
4.5
Horizontal cut
W50
904 00030
W51 22079
Riegel Transom
19.5
66.5
92 Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, horizontal, sashes with bonded glazings 137
4 5
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
93
Cutting point, vertical, sashes with bonded glazings
Recess
Sash size = Grid dimension + 1 mm
Recess
Recess
Vertical cut
Recess
10 mm dia. for drainage
www.balkan.gr
The glazing planes in the window sash and in the fixed panel are flush
94
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
Cutting point, horizontal, sashes with bonded glazings 132 1.5 5
28
4
12
904 00315
904 00025
78.5
W51 14080
50
50
PK 390
11.8
AE004-000003-00
AH550-5150003
60.4
904 00035
11.8
The glazing plane in the window sash is offset from the fixed panel!
5.5
17
34.2
43.1
AA205-101-00
9
64
28
4
12
2 119 8.5
60.4
10
25
W51 14080
15
AH550-5150003
11.8
43.1
34.2
5.5
11.8
AH275-280
904 00035
1.5
50
Horizontal cut
AH275-280
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
Cutting point, vertical, sashes with bonded glazings 132 1.5 4
28
5
78.5
904 00025
12
904 00315
3
W51 22079
50
50
PK 390
11.8
AE004-000003-00
AH550-5150003
Vertical cut
904 00035
11.8
AH275-280
12
4
28
64 2 119
5.5
11.8
904 00035
8.5 1.5
43.1
17
34.2
60.4
AH275- 280
11.8
AA205-101-00
AH550-5150003
15
W51 22079
50
10
W51 56042
www.balkan.gr
904 00025
904 00315
PK 390
The glazing plane in the window sash is offset from the fixed panel!
5.5
17
34.2
60.4
43.1
AA205-101-00
95
96
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
Cutting point, horizontal, sashes with bonded glazings 1.5 5
32
904 00025
78.5
10
50
10
W51 14080 AH550-5114080
AE004-000001-00 12.6
904 00035
5.5
85.4
48.3
43.1
AH550-5150003 W51 50003
Horizontal cut
904 00035
11.8
The glazing plane in the window sash is offset from the fixed panel!
AH275-280
14
9
64
28
85.4
48.3
AH275-280
43.1
5.5
11.8
904 00035
2
AH550-5150003
12.6
AH550-5114080 W51 14080
904 00025
10
50
10
904 00035
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
97
www.balkan.gr
The glazing plane in the window sash is offset from the fixed panel!
Vertical cut
Cutting point, vertical, sashes with bonded glazings
98
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
AH 55 051 13 00 2
Section of A turning mode (45o angle)
2 01
01
W 50
61
61
50 W
AH550-5114100
2
01
W 50
57
57
50
01
0
W 0
90째
07
W 51
22
22
51
07
9
W 9
00 13
W50 61012
51
,1
W50 57010
AH
55
0-
44
50,0
2
17,0
W 50
57
01
0
W 50
61
01
2
AH550-5114100
91122 15W
W 51
22 0
79
W51 14100
135
째
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
99
Section of A turning mode (60o angle) 7,3
50,0
7,3
34
4,3
3
,3
003
13 -51
550
AH
0 W5
61
01
W5 0
2
0 W5
57
01
W5 0
0
AH550-5114100
W5 1
79 20 12 W5
22 07 9
120째
7,3
50,0
4,3
3
W50 61012
W50 57010
03
130
51 50-
5
AH
W5
06
10
12
0 W5
57
01
0
AH550-5114100
W51 22119
79 20 12 W5
150째
www.balkan.gr
57 01 0
61 01 2
100
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
Section of A turning mode (150o angle)
16
10
29
10
16
AH550-5113004
11,3
10,2
15
32
AH550-5114104
W51 14120
150째
April 2009
www.balkan.gr
50
11
26
904 00030
11
hn De nd ba
W50 61020
W51 50080
50
37
W50 57010
11
15
W51 15080
PK 390
4 15 5
137
PK 390
The glazing plane in the window sash is offset from the fixed panel!
Vulcanised frame 904 00315
W51 22080 Transom
Riegel
35
W50 61015
W51 22079 Transom
Riegel
W50
11
W50 57010
Vulcanised frame
W51 22080 Transom
7
W50 61020
D ba ehn nd
W51 50080
Riegel
80 26
W50 61015
W51 15080
35
50
7
904 00315
904 00030
W51 22079 Transom
Riegel
15
50
Horizontal cut
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
101
Cutting point, horizontal, below or above the window sash 4
W51 22080
Transom Transom
W50 57010
53.1 50
11 50
PK 390
78.5 7 26
6.1
30
48.9 15
137 37 15
904 00075
15
5
4
PK 426
11
W50 61020
W51 22079
Transom Transom
26
The glazing plane in the window sash is offset from the fixed panel!
W50 57010
906 901
Mullion Mullion W51 14080
37
W50 61015
904 00315
904 00030
W51 22079
Transom Transom
7
11
W50 61020
904 00315
904 00030
W51 22079
Transom Transom
50
78.5
15
19.5
W51 15080
4.5
1.5
W50 61015
904 00100
5
Horizontal cut 1.5
W51 50015
W51 50053
42
66.5
102 Curtain Wall system for facades and roofs building construction Series W 50 W50 Thermal-insulated Cutting points
Cutting point, horizontal, sash/fixed glazing 137
4 5
4
122
5
April 2009
on
www.balkan.gr
80
137
W50 61020
11
hn De nd ba
50
78.5 7
7
W50 57010
W51 14080
Mullion Pfosten
11 50
906 901
PK 390
26
37
26
15
37 15
PK 390
15
11
W50 61020
W51 22079
Transom Riegel
37
W50 61015
904 00315
904 00030
W51 22079
Riegel Transom
26
W50
11
W51 22079
Transom Riegel
50
7
W50 57010
W51 15080
15
78.5
904 00315
904 00030
W51 50080
50 1.5
W50 61015
W51 22080
Riegel Transom
35
1.5
E str xpa ip ns i
Horizontal cut Horizontalschnitt
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
103
Cutting point, horizontal, below or above the window sash 137 5
4
137 5
4
4
5
104
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting points, inclined glazing
Manufacture from PK 79
Purlin of transoms g
50
Spars of mullions to meet static requirements
of
n
Purli
PK
mm
lon
79,
oms
ns of tra
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, frame insert, Series RG 75 block window for facade
Mullion
Axis
www.balkan.gr
W50
105
106
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, frame insert, Series RG 75 for facade
Mullion
Axis
Door opening inwards
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
107
Cutting point, frame insert, Series RG 75 for facade
Mullion
Axis
Positioning aid for 6 mm groove, twisted and not pinned
Drilling template
Door opening outwards
www.balkan.gr
108
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, vertical facade, top Design draft
Attic cover
Sealing tapes
Ventilation Air inlet in mullion area
Mullion
Transom
Transom
Ventilation Drainage Air inlet in the transom area
Mullion
Sliding profile
Cross section
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
109
Cutting point, vertical facade, top
Back-ventilated LM cold facade
Design draft
Sealing tapes
Suspended ceiling
Ventilation Air inlet in mullion area
Mullion
Transom
Transom
Ventilation Drainage Air inlet in the transom area
Mullion
Sliding profile
Cross section
www.balkan.gr
110
W50
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, vertical facade, in front of a ceiling
Mullion
Design draft
Transom
Finished floor level
Ventilation Drainage Air inlet in the transom area
Anchoring and - Quantity and - Distribution of the bolts: According to statics
Mullion butt joint with reinforcement
Suspended ceiling
Transom Sliding profile Mullion
Ventilation Drainage Air inlet in the transom area
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
111
Cutting point, vertical facade, lateral
Sliding profile
Mullion
Design draft
www.balkan.gr
Transom
W50
112
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
Cutting point, vertical facade, bottom
Transom
Horizontal cut
Design draft
Mullion
Sliding Profile
Vertical cut
Finished floor level Sealing tape Ventilation Drainage Air inlet in the mullion area
Ventilation Drainage Air inlet in the mullion area
April 2009
Curtain Wall system for facades and roofs Thermal-insulated building construction Series W 50 Cutting points
W50
113
Cutting point, vertical facade, bottom
Transom
Horizontal cut Mullion
Design draft
Vertical cut
L profile
Sealing tape Ventilation Drainage Air inlet in the mullion area
Ventilation Drainage Air inlet in the mullion area
www.balkan.gr
Finished floor level