STAIRS / DECKS Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING All stairways and landings leading to and from building entrances are provided with adequate illumination by a working light ďŹ xture.

IRC 311.5.7 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING All stairways are safe to use and capable of supporting the normal loads and uses placed upon them.

IRC 311.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING There are minimum headroom clearances of 6 feet 8 inches maintained at all points of all stairway passages. [Exception: Spiral Stair Cases require a minimum headroom clearance of only 6 feet 6 inches].

IRC 311.5.8.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING The minimum riser height any step is 4 inches.

4" minimum

IRC 311.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING The maximum riser height any step is 7 ! inches.

7 3/4 " maximum

IRC 311.5.3.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING The minimum tread depth of any step is 10 inches.

i in

m

M " 0

1

IRC 311.5.3.2 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com

um


STAIRWAYS & DECKING If present, the protrusion of any step nosing for any stairway tread is a minimum of ! inch overhang beyond any supporting riser and no more than of 1 " of an inch beyond any supporting riser.

IRC 311.5.3.3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com

N p te

S

g

n i s o


STAIRWAYS & DECKING 34"-38"

All handrails are securely attached at the proper height of 34-38 inches high as measured from the nose of each stair tread.

IRC 311.5.6.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING All handrails are securely attached at the proper height of 34-38 inches high as measured from the nose of each stair tread.

IRC 311.5.6.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING Handrails are full length and are properly located on the open sides of stairways. (If a stairway is open at both sides then a full-length handrail shall be present on both sides).

IRC 311.2 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING All visible and accessible components of exterior stairways and decks are safe for pedestrian use.

IRC 311.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING All visible and accessible components of exterior stairways have been maintained in a professional state of repair.

IRC 311.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING There are no missing stair or decking components where visible and accessible.

IRC 311.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING There are no damaged components, including damage due to insect infestation, to any stairway or decking components where visible and accessible.

IRC 311.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING There are no rotted stairway or decking components that would be considered unsafe where visible and accessible.

IRC 311.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING There are no open porches; no accessible at roofs; no decks; and no stoops that are located more than 30 inches above an adjoining horizontal surface that lack proper guardrails.

IRC 312.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


STAIRWAYS & DECKING 4" All guardrails are a minimum of 36 inches in height with intermediate rails that are properly spaced so that a 4 inch sphere can not pass through any opening in the guardrail. (An exception is made for properly installed safety-glass panels that conform to said height and opening requirements.)

IRC 312.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL Areas accessible to pedestrian foot traffic maintain 10’ clearances from Electric Service Wires adjacent to buildings.

IRC 230.24B1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL General grounds areas at large maintain 12’ clearances from Electric Service Wires.

IRC 230.24B2 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL Areas above driveway, carport and garage areas accessible to vehicle traffic maintain 12’ clearances.

IRC 230.24B2 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL Pool and/or hot tub installations are set back from overhead Electric Service Wires and maintain 22 # ‘ horizontal clearances from any overhead Electric Service Wires.

NEC 680.8A Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL W indow installations maintain 3’ clearances below or to the sides of operable windows from Electric Service Wires.

IRC 230.9A Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL Decks and balconies maintain 10’ clearances (at all points out to 3’ horizontal) from any overhead Electric Service Wires.

IRC 230.9B Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL Trees have not been used to support overhead Electric Service Wires.

IRC 230.10 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL All exterior light fixtures are installed per the manufacturer’s instructions, have been properly maintained, and in good working order. There are no exposed wires, broken conduits, broken fixtures, broken light bulbs, broken sockets, missing cover plates or the like.

IRC 210 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL There exists no improperly secured nor improperly exposed exterior wiring of any kind above the ground, including electrical extension cords, strand lighting, or the like, (low-voltage landscape lighting is excluded.)

IRC 210 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL All exterior receptacles are provided with a weather-tight cover; are properly installed; are properly grounded; and are protected by a Ground Fault Circuit Interrupter (GFCI).

IRC 210.8A3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL All exterior receptacles are provided with a weather-tight cover; are properly installed; are properly grounded; and are protected by a Ground Fault Circuit Interrupter (GFCI).

IRC 210.8A3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL All interior receptacles serving kitchens, bathrooms, laundry tubs, and or wet bars are properly installed; are properly grounded; and are protected by a Ground Fault Circuit Interrupter (GFCI).

IRC 210.8A6 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com

GFCI Test/Reset


ELECTRICAL All light switches, fan switches, and light ďŹ xtures maintain a minimum clearance of 3' from all shower, tub, and sauna installations.

IRC 210.8A3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL The main electrical service panel installation has been safely installed and maintained. The electric service panel installation provides a minimum working clearance of 30 inches wide by 36 inches deep where installed and is readily accessible.

IRC 110.26A Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL There are no missing breakers, no missing fuses, no improperly exposed wires, and no missing cover components at the main electric service panel.

IRC 110.12A Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL Receptacles and light ďŹ xtures are free from missing or damaged components.

IRC 210 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


ELECTRICAL The inspector has randomly checked at least half of all electrical receptacles with an electrical testing device and has determined that the representative sampling of electrical receptacles tested are properly wired.

IRC 210 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FOUNDATION Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FOUNDATION Where visible and accessible, the base walls or posts were carefully evaluated for leaning, cracking, buckling or bulging conditions which may indicate structural failure. There are no missing or damaged components that would indicate a lack of structural integrity.

IRC 404,506 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FOUNDATION Where visible and accessible, the base walls or posts were carefully evaluated for leaning, cracking, buckling or bulging conditions which may indicate structural failure. There are no missing or damaged components that would indicate a lack of structural integrity.

IRC 404,506 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


HOUSE #'S Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


HOUSE NUMBERS House numbers are properly posted in a location where they can be readily identiďŹ ed by emergency personnel and county services.

NON-CODIFIED Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES WOODSTOVE Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES Masonry fireplaces maintain minimum hearth extension depths of 16” to the front and 8” to each side where the fireplace opening is less than or equal to 6 square feet.

Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES Masonry fireplaces maintain minimum hearth extension depths of 20” to the front and 12” to each side where the fireplace opening is greater than 6 square feet.

Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES An operable damper has been provided for all ďŹ replaces.

Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES Wood stoves are installed on a non-combustible floor material that extends 18” beyond stove on all sides.

Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES Single wall vent connections for wood stoves maintain 18� clearances from combustibles at all points exposed to the living area. (Exception is made for approved wood stove clearance reduction systems.)

Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES All wood stove vent connections maintain a minimum rise of "� per foot from appliance collar to chimney.

Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES There exists no visible evidence of loose, cracked, missing, or damaged components at ďŹ replaces, nor at wood stove installations.

Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


FIREPLACES & WOOD STOVES Written Operating Instructions explaining the use of all ďŹ replaces and/or wood stoves have been made available to guests.

STR CODIFIED Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


HEATING SYSTEM Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


HEATING SYSTEM The exterior and interior areas of the heating plant(s) do not present any overt signs of leakage, cracks, rust, scorched areas, missing components, or deteriorated seals.

IRC 1202.3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


HEATING SYSTEM There are no missing or visibly defective control elements.

IRC 1202.3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


HEATING SYSTEM Proper clearances from combustibles have been maintained at all heating plant installations.

IRC 1803 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


HEATING SYSTEM Proper clearances from combustibles have been maintained at all heating plant vent connections where visible and readily accessible.

IRC 1803 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING All gas piping connections where visible and readily accessible have been maintained in a professional state of repair.

IRC 2414 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING There exist no uncapped gas lines where visible and readily accessible.

IRC 2415.12 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING All gas valves at appliances present ready access.

IRC 2420.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Each gas appliance is provided with a gas shut-off valve within 6’ of appliance and within the same room as gas appliance.

IRC 2420.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING No gas shut-off valves have been installed within solid fuel burning ďŹ replaces.

IRC 2420.5.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING The maximum length of flexible (corrugated metal) gas connectors is 3’ at appliances, with the exception 6’ lengths permitted for ranges and dryers.

IRC 2422.1.2 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Flexible (corrugated metal) gas connectors are installed entirely within t h e s a m e ro o m a s g a s b u r n i n g appliance.

IRC 2420.5 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING No flexible (corrugated metal) gas connectors pass through wall, floor or ceiling assemblies.

IRC 2422.1.2.3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Rubber gas hosing is permitted only for outdoor portable appliances.

UPC 1212B Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Plastic gas tubing is permitted only underground and outside of dwelling.

IRC 2414.6 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING All visible connections of the water heater(s) are in good condition.

IRC 2801.3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING There is no evidence of excessive rusting, scorching, leaking, missing, or broken water heater components where visible and readily accessible.

IRC 2801.3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING All water heaters are equipped with a properly located temperature and pressure relief valve.

IRC 2803.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING All temperature and pressure relief valves are equipped with a discharge pipe located 6 to 18 inches from the oor.

IRC 2803.6.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING If a gas water heater, the appliance is ďŹ rmly situated on a non-combustible oor, is properly installed, the draft hood and vent piping are in working order, and the vent piping is both of an approved material and presents proper clearances from combustibles

IRC 1308.3/2428.2 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING There are no broken, cracked, leaking, deteriorated or improperly maintained plumbing ďŹ xtures that create an unsanitary condition.

IRC 2701.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING The water service shut-off for the home is clearly labeled, accessible and the location is provided to guests.

IRC 2903.9.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


SLEEPING ROOMS Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING A drawing has been provided to the Inspector in 8 #” by 11” or 11” x17” format designating which specific rooms are to be used as sleeping rooms for the purposes of guest accommodations. This drawing shall be signed by the Inspector on the lower right hand side of the drawing.

STR CODIFIED Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING All sleeping rooms so designated by the drawing provided to the Inspector meet the minimum room dimensions of 70 square feet.

IRC 304.2 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING All sleeping rooms so designated meet the minimum dimensions for ceiling height of 7 feet.

IRC 305.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING There exist no openings from an enclosed garage directly into a room designated to be used for sleeping purposes.

IRC 309.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Smoke detectors are located within sleeping rooms designated for use by guests.

IRC 313.2 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING A written log showing the monthly testing of all smoke detectors with the ďŹ rst entry showing all detectors to be in working order is present.

STR CODIFIED Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Height x Width= 5.7 Square Foot Area

All sleeping rooms are equipped with at least one proper egress window which presents a minimum clear opening of 5.7 square feet as framed (an exception of 5.0 square feet is made for egress windows which open from sleeping rooms directly to grade level.)

IRC 310.1.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Any requisite egress window is a minimum of 20 inches wide as framed.

20"

IRC 310.1.2.3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


PLUMBING Any requisite egress window is a minimum of 24 inch tall as framed.

24"

IRC 310.1.2.3 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


GARAGES OUTBUILDING Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


GARAGES & OUT BUILDINGS All service doors connecting any dwelling to an attached garage that is enclosed are either solid core wood with a minimum thickness of 1 3/8 inches throughout their fabrication, or are equipped with a ďŹ re-resistant metal cladding.

IRC 309.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


GARAGES & OUT BUILDINGS Where an overhead garage door has been equipped with an automatic garage door opener, the opener was observed to have properly reversed the direction of door travel upon the presence of, or contact with, a two-inch high rigid obstacle placed on the horizontal surface directly beneath the garage door or, was tested, to have properly reversed via the interruption of a laser-eye safety device which has been properly installed 4-6 inches from the oor.

16 CFR 1211 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com


GARAGES & OUT BUILDINGS Section R105.1 requires a permit whenever work, "the installation of which is regulated by this code" is done.

IRC 105.1 Prepared for Maui Vacation Rental Association Courtesy of Thomas Lewis, www.CertiTechInspections.com