Issuu on Google+

6U 12-Slot VPX Backplane 1” Pitch


TABLE OF CONTENTS Standard Technical Documentation:

6U 12 Slot VPX Backplane

Information Connector pin-out tables for each slot type Connector pin-out tables and part numbers for all cable connectors Tables showing power connections and current ratings Tables showing jumper locations and jumper functions Optional terminations and default termination information (if applicable) Fabric connection diagram (if applicable), along with this information in a tabular form Illustrations showing locations of all slot connectors, keys as well as power connections, cable connectors and jumpers

1 877 HYBRICON 1

Page Number 2 3 3 4 4 5 6&7

WWW.HYBRICON.COM


CONNECTOR PINOUT TABLES Connector Pin Out Tables (VPX Slots) J0

Row A

Row B

Row C

Row D

Row F

Row G

Row H

Row I

1

VS2

VS2

VS2

VS2

VS1

VS1

VS1

VS1

2

VS2

VS2

VS2

VS2

VS1

VS1

VS1

VS1

3

VS3

VS3

VS3

VS3

VS3

VS3

VS3

VS3

4

GND

NVMRO

SYSREST*

GND

-12 VAUX

GND

SM3

SM2

GND

5

GND

SM1

SM0

GND

+3.3 VAUX

GND

GND

6

GND

GND

GND

+12 VAUX

GND

GND

7 8

GND

GND

GND

GND

RES_BUS+

RES_BUS-

Row E

GND

GND

GND

GND

REF_CLK+

REF_CLK-

GND

J1

Row A

Row B

Row C

Row D

Row E

Row F

Row G

Row H

Row I

1

PA1_RD3+

PA1_RD3-

GND

GND

PA1_TD3+

PA1_TD3-

GND

GND

P1-RES_BUS_SE

2

GND

GND

PA1_RD2+

PA1_RD2-

GND

GND

PA1_TD2+

PA1_TD2-

GND

3

P1A_RD1+

PA1_RD1-

GND

GND

PA1_TD1+

PA1_TD1-

GND

GND

P1-VBAT

4

GND

GND

PA1_RD0+

PA1_RD0-

GND

GND

PA1_TD0+

PA1_TD0-

GND

5

PB1_RD3+

PB1_RD3-

GND

GND

PB1_TD3+

PB1_TD3-

GND

GND

SYS_CON1* GND

6

GND

GND

PB1_RD2+

PB1_RD2-

GND

GND

PB1_TD2+

PB1_TD2-

7

PB1_RD1+

PB1_RD1-

GND

GND

PB1_TD1+

PB1_TD1-

GND

GND

8

GND

GND

PB1_RD0+

PB1_RD0-

GND

GND

PB1_TD0+

PB1_TD0-

9

PC1_RD3+

PC1_RD3-

GND

GND

PC1_TD3+

PC1_TD3-

GND

GND

10

GND

GND

PC1_RD2+

PC1_RD2-

GND

GND

PC1_TD2+

PC1_TD2-

11

PC1_RD1+

PC1_RD1-

GND

GND

PC1_TD1+

PC1_TD1-

GND

GND

12

GND

GND

PC1_RD0+

PC1_RD0-

GND

GND

PC1_TD0+

PC1_TD0-

13

PD1_RD3+

PD1_RD3-

GND

GND

PD1_TD3+

PD1_TD3-

GND

GND

14

GND

GND

PD1_RD2+

PD1_RD2-

GND

GND

PD1_TD2+

PD1_TD2-

15

PD1_RD1+

PD1_RD1-

GND

GND

PD1_TD1+

PD1_TD1-

GND

GND

16

GND

GND

PD1_RD0+

PD1_RD0-

GND

GND

PD1_TD0+

PD1_TD0-

1 877 HYBRICON 2

GND GND GND GND GND

WWW.HYBRICON.COM


CONNECTOR PINOUT/POWER TABLES Cable Connectors

Connector JP4 - Insert Jumper for VBAT = +3.3V Local Connector JP5 - Acces for Independent VBAT JP4

Signal

JP5

Signal

1

P1-VBAT

1

P1-VBAT

2

+3.3 VAUX

2

GND

Single Ended System Management Connections Header: 0.025” Sq. Pins, 0.10” Spacing W12 Pin

Signal

1

GND

2

SM3

3

SM2

4

SM1

5

SM0

Power Connections / Current Ratings Connection

Power Rail

Size

Current

ST 1

VS1

#10

80A

ST 2

VS1

#10

80A

ST 3

VS1

#10

80A

ST 5

VS2

#10

80A

ST 6

VS2

#10

80A

ST 7

VS2

#10

80A

ST 9

GND

#10

80A

ST 10

GND

#10

80A

ST11

GND

#10

80A

ST13

GND

#10

80A

ST14

GND

#10

80A

ST15

GND

#10

80A

ST17

+5V

#10

80A

ST18

+5V

#10

80A

ST19

+5V

#10

80A

ST20

+5V

#10

80A

ST21

GND

#10

80A

ST22

GND

#10

80A

ST23

GND

#10

80A

ST24

GND

#10

80A

Connector PWR1: 232-223-24 Molex 43879-0043

Connector JX1: 232-506-06 Molex 43045-0619

Pin

Power Rail

Current

Pin

1

+3.3 VAUX

8A

2

+3.3 VAUX

8A

3

+3.3 VAUX

8A

4

+3.3 VAUX

8A

5

+12 VAUX

8A

6

+12 VAUX

8A

7

+12 VAUX

8A

8

+12 VAUX

8A

9

-12 VAUX

8A

10

-12 VAUX

Current

1

ACFAIL*

2A

2

SYSFAIL*

2A

3

SYSRESET*

2A

4

GND

2A

5

GND

2A

6

GND

2A

8A

Connector JX2: 232-506-12 Molex 43045-1219 Sense Connections

Connector JX3: 232-506-12 Molex 43045-1219 Sense Connections

Pin

Pin

11

-12 VAUX

8A

12

-12 VAUX

8A

13

GND

8A

14

GND

8A

15

GND

8A

16

GND

8A

17

GND

8A

18

GND

8A

19

GND

8A

20

GND

8A

21

GND

8A

22

GND

8A

23

GND

8A

24

GND

8A

1 877 HYBRICON

Power Rail/ Signal

Power Rail/ Signal

Current

Power Rail/ Signal

1

+5V

1

+5V

2

+3.3 VAUX

2

+3.3 VAUX

3

+12 VAUX

3

+12 VAUX

4

-12 VAUX

4

-12 VAUX

5

VS1

5

VS1

6

VS2

6

VS2

7

GND

7

GND

8

GND

8

GND

9

GND

9

GND

10

GND

10

GND

11

GND

11

GND

12

GND

12

GND

3 2

Current

WWW.HYBRICON.COM


JUMPERS/OPTIONAL TERMINATIONS Jumpers Jumper: Zero OHM Resistance Jumper

Jumper Function

Default

Jumper

Jumper Function

Default

JP3

NVMRO

Not Installed

R88

Slot 6 SYSCON*

Not Installed

R83

Slot 1 SYSCON*

Installed

R89

Slot 7 SYSCON*

Not Installed

R84

Slot 2 SYSCON*

Not Installed

R90

Slot 8 SYSCON*

Not Installed

R85

Slot 3 SYSCON*

Not Installed

R91

Slot 9 SYSCON*

Not Installed

R86

Slot 4 SYSCON*

Not Installed

R92

Slot 10 SYSCON*

Not Installed

R87

Slot 5 SYSCON*

Not Installed

R93

Slot 11 SYSCON*

Not Installed

R94

Slot 12 SYSCON*

Not Installed

Optional Terminations & Default Termination Info. Bus REF_CLK

Termination Default 61.9 Ohms Differential

REF_BUS

none

NVRMO

220 Ohms to 3.3 VAUX

RES_BUS_SE

none

SYSRESET*

220 Ohm/1.8k Ohm pullup/ down to 3.3 VAUX

SM (0-3)

none

1 877 HYBRICON 4

WWW.HYBRICON.COM


FABRIC CONNECTION/ILLUSTRATIONS Fabric Connection 4X Link From

4X Link To

Slot From

Port From

Slot To

Port To

1

A

2

A

1

B

3

A

1

C

4

A

1

D

11

D

2

B

3

B

2

C

4

B

2

D

12

D

3

C

4

C

3

D

5

D

4

D

6

D

5

A

6

A

5

B

7

A

5

C

8

A

6

B

7

B

6

C

8

B

7

C

8

C

7

D

9

D

8

D

10

D

9

A

10

A

9

B

11

A

9

C

12

A

10

B

11

B

10

C

12

B

11

C

12

C

Illustrations 1” Pitch

1 877 HYBRICON

5

WWW.HYBRICON.COM


ILLUSTRATIONS Illustrations <

<

12.965”

<

Key 1 J0 J1 J2

J3

10.317”

Key 2

J4

J5

Key 3

<

J6

SLOT

KEY 1 (top)

KEY 2 (middle)

KEY 3 (bottom)

SLOT

KEY 1 (top)

KEY 2 (middle)

KEY 3 (bottom)

1

315 dregees

270 degrees

270 degrees

7

315 dregees

315 degrees

315 degrees

2

315 dregees

315 degrees

270 degrees

8

315 dregees

0 degrees

315 degrees

3

315 dregees

0 degrees

270 degrees

9

315 dregees

45 degrees

315 degrees

4

315 dregees

45 degrees

270 degrees

10

315 dregees

90 degrees

315 degrees

5

315 dregees

90 degrees

270 degrees

11

315 dregees

270 degrees

0 degrees

6

315 dregees

270 degrees

315 dregees

12

315 dregees

315 degrees

0 degrees

1 877 HYBRICON 6

WWW.HYBRICON.COM


ILLUSTRATIONS Illustrations

JX3

JX1

JX2

GND GND

GND

GND

GND

VS2 +12V

GND

VS2 +12V

GND

VS2 +12V

VS1 +12V VS3 +5V

VS1 +12V

VS3 +5V

VS1 +12V

VS3 +5V

GND

VS3 +5V

GND

GND Key 3

Key 2

Key 1

SLOT

KEY 1 (top)

KEY 2 (middle)

KEY 3 (bottom)

SLOT

KEY 1 (top)

KEY 2 (middle)

KEY 3 (bottom)

1

315 dregees

270 degrees

270 degrees

7

315 dregees

315 degrees

315 degrees

2

315 dregees

315 degrees

270 degrees

8

315 dregees

0 degrees

315 degrees

3

315 dregees

0 degrees

270 degrees

9

315 dregees

45 degrees

315 degrees

4

315 dregees

45 degrees

270 degrees

10

315 dregees

90 degrees

315 degrees

5

315 dregees

90 degrees

270 degrees

11

315 dregees

270 degrees

0 degrees

6

315 dregees

270 degrees

315 dregees

12

315 dregees

315 degrees

0 degrees

1 877 HYBRICON

7

WWW.HYBRICON.COM


6U 12-Slot VPX Backplane Standard Technical Document