GENERAL NOTES/CONDITIONS:

GENERAL NOTES/CONDITIONS:

1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRICUTION FACILITY (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES, WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. OBTAIN APPROVAL FROM THE REAL ESTATE BUSINESS UNIT OF THE DEPARTMENT OF WATER AND POWER, (213) 367-0562.

1. ALL MATERIAL STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT DAMAGE AND DETERIORATION UNTIL USE. FAILURE TO PROTECT MATERIALS MAY BE CAUSE FOR REJECTION OF WORK.

2. OBTAIN PERMITS FROM PUBLIC WORKS PRIOR TO COSTRUCTION FOR TEMPORARY PEDESTRIAN PROTECTION AS REQUIRED BY LABC SECTION 303.7 FOR ANY CONSTRUCTION NEAR ANY STREET OR PUBLIC AREA.

3. ALL PRODUCTS, MATERIALS AND FINISHES TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS--NO EXCEPTIONS.

2. ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND/OR AS REQUIRED BY THE ADOPTED EDITION OF THE UNIFORM BUILDING CODE AND ALL LOCAL AND NATIONAL CODES AND AUTHORITIES WHICH ARE APPLICABLE.

4. ALL DIMENSIONS TO FINISHES UNLESS NOTED OTHERWISE. 3. PROVIDE ELECTRICAL OUTLETS ALONG THE WALLS OF COUNTER SPACE, ISLAND AND PENINSULA COUNTER SPACE IN KITCHENS AT MAXIMUM SPACING OF 48 INCHES. 4. THE LIGHTS IN THE NEW AND REMODELED BATHROOMS AND KITCHEN SHALL BE ENERGY EFFICIENT TYPES MEETING MINIMUM 40 LUMENS PER WATT, E.G. FLUORESCENT TYPES. 5. ALL SHOWER ENCLOSURES, REGARDLESS OF SHAPE, SHALL HAVE A MINIMUM FINISHED INTERIOR AREA OF NOT LESS THAN 1,024 SQUARE INCHES AND SHALL BE CAPABLE OF ENCOMPASSING A 30 INCH DIAMETER CIRCLE. THE MINIMUM AREA AND DIMENSIONS SHALL BE MAINTAINED TO A POINT 70 INCHES ABOVE THE SHOWER DRAIN OUTLET. 6. A MINIMUM 12 INCH SQUARE ACCESS PANEL TO THE BATHTUB TRAP SLIP JOINT CONNECTION IS REQUIRED. 7. PROVIDE GROUND-FAULT CIRCUIT INTERRUPTER PROTECTED ELECTRICAL OUTLETS WITHIN 36 INCHES OF THE EDGE OF EACH BASIN. THE BATHROOM OUTLETS SHALL BE FED FROM A DEDICATED 20 AMP CIRCUIT AT THE PANEL. 8. CLOTHES DRYER(S) LOCATED IN AN AREA THAT IS HABITABLE OR CONTAINING FUEL BURNING APPLIANCES SHALL BE EXHAUSTED TO THE OUTSIDE. 9. A 4-INCH DIAMTER CLOTHES DRYER MOISTURE EXHAUST DUCT IS LIMITED TO A 14 FEET LENGTH WITH TWO ELBOWS FROM THE CLOTHES DRYER TO THE POINT OF TERMINATION. REDUCE THIS LENGTH BY 2 FEET FOR EVERY ELBOW IN EXCESS OF 2. 10. PROVIDE 32" WIDE DOORS TO ALL INTERIOR ACCESSIBLE ROOMS WITHIN A DWELLING UNIT. 11. PROVIDE EMERGENCY EGRESS FROM SLEEPING ROOMS: 24" CLEAR HEIGHT MINIMUM, 20" CLEAR WIDTH MINIMUM, 5.7 SQ.FT. MINIMUM AREA. 12. PROVIDE UNDER-FLOOR NET VENTILATION OPENING SIZE AND LOCATIONS EQUAL TO 1 SQ.FT. FOR EACH 150 SQ.FT. OF UNDER FLOOR AREA AND UNDERFLOOR ACCESS CRAWL HOLE (18 X 24 INCHES). OPENINGINGS SHALL BE AS CLOSE TO CORNERS AS PRACTICABLE AND SHALL PROVIDE CROSS VENTILATION ALONG THE LENGTH OF AT LEAST TWO OPPOSITE SIDES. OPENING SHALL HAVE 1/4 INCH CORROSION RESISTANT METAL MESH COVERING. 13. PROVIDE CORROSION RESISTANT WEEP SCREED BELOW THE STUCCO A MINIMUM OF 4" ABOVE EARTH OR 2" ABOVE PAVED AREA.

topa architecture 1 6 5 0 Z a n k e r R d. # 2 3 1

DO NOT SCALE FROM DRAWINGS.

5. VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO COMMENCING ANY WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR INCONSISTENCIES WITH THESE PLANS AND SPECIFICATIONS OR ANY UNFORESEEN CONDITIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. 6. MAINTAIN THE JOB SITE IN A CLEAN, ORDERLY CONDITION FREE OF DEBRIS AND LITTER, EACH SUBCONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF HIS WORK SHALL REMOVE ALL TRASH AND DEBRIS AS A RESULT OF HIS OPERATION. THE JOB SITE SHALL BE LEFT CLEAN AND SWEPT EACH DAY BY THE END OF WORK THAT DAY. 7. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN REVIEWED AND ACTED UPON BY THE ARCHITECT. ALL SUCH PORTIONS OF WORK SHALL BE IN ACCORDANCE WITH THE REVIEWED SHOP DRAWINGS AND SAMPLES. 8. CONFINE OPERATIONS AT THE SITE TO AREAS PERMITTED BY LAW, ORDINANCES, PERMITS AND THE CONTRACT DOCUMENTS, AND SHALL NOT UNREASONABLY ENCUMBER THE SITE WITH ANY MATERIAL OR EQUIPMENT. 9. SHOULD AN ERROR APPEAR IN SPECIFICATIONS OR DRAWINGS, OR IN WORK DONE BY OTHERS, AFFECTING THIS WORK, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTIONS AS TO PROCEDURE. IF CONTRACTOR PROCEEDS WITH WORK AFFECTED WITHOUT INSTRUCTIONS FROM THE ARCHITECT, THE CONTRACTOR SHALL MAKE GOOD ANY RESULTING DAMAGE OR DEFECT.

S a n J o s e C A, 9 5 1 1 2 Tel (408) 320 - 0248 GENERAL NOTES:

1. THIS SHEET IS PART OF A SET & IS NOT TO BE USED ALONE. 2. THIS SHEET IS NOT FOR CONSTRUCTION UNTIL THE ARCHITECT'S STAMP & SIGNATURE ARE ON THIS SHEET. 3. THESE PLAN & PRINTS ARE OWNED BY THE ARCHITECT & ARE FOR USE ON THIS PROJECT ONLY. REPRODUCTION AND/OR DISTRIBUTION WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT IS FORBIDDEN.

10. SHOULD CONFLICT OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS OR WHERE DETAIL REFERENCES ON CONTRACT DRAWINGS HAVE BEEN OMITTED, CONTRACTOR IS DEEMED TO HAVE ESTIMATED THE MOST EXPENSIVE MATERIALS AND CONSTRUCTION INVOLVED UNLESS HE SHALL HAVE ASKED FOR AND OBTAINED WRITTEN DECISION FROM THE ARCHITECT AS TO WHICH METHOD OR MATERIALS WILL BE REQUIRED. 11. ALL PATCHING, REPAIRING AND REPLACING OF MATERIALS AND SURFACES CUT OR DAMAGED IN EXECUTION OF WORK SHALL BE DONE WITH APPLICABLE MATERIALS SO THAT SURFACES REPLACED WILL, UPON COMPLETION, MATCH SURROUNDING SIMILAR SURFACES 12. SEE DOCUMENTS PREPARED BY THE CIVIL ENGINEERING, IF APPLICABLE, FOR ALL FINISH GRADES, DRAINAGE AND SITE DETAILS. REVIEW ALL SITE UTILITY DOCUMENTS, LANDSCAPE AND IRRIGATION DOCUMENTS PRIOR OR COMMENCEMENT OF ANY UNDERGROUNDING OR TRENCHING. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL STRUCTURES. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OF THE CONTRACT DOCUMENTS.

PROJECT:

14. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. 15. A/C UNITS AND WATER HEATERS ARE NOT ALLOWED IN THE REQUIRED SIDE YARD AND FRONT YARD. 16. GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED: INGRESS AND EGRESS DOORS; PANELS IN SLIDING OR SWINGING DOORS; DOORS AND ENCLOSURES FOR HOT TUB, BATHTUB AND SHOWERS. GLAZING IN WALL ENCLOSING THESE COMPARTMENTS WITHIN 5' OF STANDING SURFACE; IN WALL ENCLOSING STAIRWAY LANDING. EACH LIGHT OF SAFETY GLAZING (PANE) MATERIAL INSTALLED IN HAZARDOUS LOCATIONS SHALL BE IDENTIFIED BY A PERMANENT LABEL THAT SPECIFIES THE LABELER, AND STATES THAT SAFETY GLAZING MATERIAL HAS BEEN UTILIZED IN SUCH INSTALLATIONS. 17. PRE-FAB FIREPLACES ARE REQUIRED TO HAVE MANUFACTURER, MODEL, AND UNDERWRITER'S LABORATORIES CERTIFICATION (OR ICBO). 18. PROVIDE AN APPROVED SPARK ARRESTER FOR THE CHIMNEY OF A FIREPLACE, STOVE, OR BARBECUE WHICH USES FUEL BURNING MATERIAL. 19. AN APPROVED SEISMIC GAS SHUTOFF VALVE SHALL BE INSTALLED INTO THE FUEL GAS LINE AT THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. 20. WATER HEATER MUST BE STRAPPED TO THE WALL.

13. CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS AGREE THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS FURTHER AGREE TO DEFEND, INDEMNIFY AND HOLD THE ARCHITECT HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPT LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE ARCHITECT AS IDENTIFIED IN ITEM # 14 OF THESE GENERAL CONDITIONS. 14. GENERAL CONTRACTORS, SUB-CONTRACTORS, BUILDERS, AND OWNER ARE TO CHECK ALL DRAWINGS FOR ERRORS AND OMISSIONS PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANY ERRORS AND/OR OMISSIONS MUST BE REPORTED IMMEDIATELY TO THE ARCHITECT IN WRITING PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DESIGNER WILL NOT TAKE LIABILITY FOR ANY ERRORS AND/OR OMISSIONS NOT REPORTED IMMEDIATELY IN WRITING PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE ARCHITECTS' LIABILITY FOR THE TOTAL PROJECT SHALL NOT EXCEED ONE THOUSAND DOLLARS.

WALTER'S KITCHEN 974 Palm Street San Jose CA CONSULTANT:

15. ALL SCREWS/NAILS IN FINISH WOODWORK TO BE COUNTERSUNK AND FILLED SMOOTH WITH PUTTY TO MATCH FINISH. 16. IF THE MANUFACTURER'S SPECIFICATIONS AND APPLICABLE CODES ARE NOT CONSISTENT WITH EACH OTHER, NOTIFY THE ARCHITECT IMMEDIATELY PRIOR TO COMMENCEMENT OF ANY WORK AND AWAIT DIRECTION OR CONTRACTOR ACCEPTS FULL RESPONSIBILITY OF WORK COMPLETED.. 17. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8" TYPE "X" SHEETROCK, SMOOTH FINISH OR AS OTHERWISE INDICATED ON DRAWINGS. INSTALL AS NEEDED TO MEET APPLICABLE CODES. 18. ELECTRICAL, MECHANICAL, PLUMBING, FIRE EXTINGUISHING SYSTEM AND FIRE ALARM SYSTEM TO BE DESIGN/BUILD. SHOP DRAWINGS TO BE PROVIDED TO DESIGNER PRIOR TO CONSTRUCTION.

SHEET TITLE: 19. A DELTA SYMBOL LOCATED AT THE LOWER RIGHT HAND CORNER OF ANY DRAWING INDICATES THAT DRAWING HAS BEEN SIGNIFICANTLY REVISED AND SHOULD BE TREATED AS AN ENTIRELY NEW DRAWING. 20. CONTRACTOR TO PROTECT ALL INTERIOR SPACES (AS REQUIRED) FROM ANY WEATHER, THEFT, OR VANDALISM.

GENERAL NOTES

21. ALL WALLS FLOORS AND CEILINGS ARE TO BE FINISHED TO MATCH EXISTING ADJACENT SURFACES. ALL NEW FINISHES AND FIXTURES ARE TO BE APPROVED BY OWNER OR ARCHITECT, PRIOR TO INSTALLATION. 22. RELOCATE OR INSTALL NEW PLUMBING, GAS, AND ELECTRICAL LINES (AS REQUIRED) FOR THE NEW CONSTRUCTION. 23. CONTRACTOR TO DISPOSE OF ALL DEBRIS AT AN APPROVED DUMP SITE PER ALL TOWN, COUNTY, STATE AND FEDERAL REGULATIONS.

REVISIONS

BY

24. CONTRACTOR TO NOTIFY OWNER AND ARCHITECT IF HE SUSPECTS THAT ANY ASBESTOS IS ON SITE AND STOP WORK IMMEDIATELY UNTIL AUTHORITIES HAVE PROVED THE WORK TO BE SAFE. 25. SMOKE DETECTORS SHALL BE INSTALLED IN ALL BEDROOMS AND HALLS. 26. PROVIDE A MINIMUM 70" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWERS AND APPROVED SHATTER RESISTANT MATERIALS FOR SHOWER ENCLOSURE.