UNION STATION NORTH ENTRANCE

Page 1


DRAWING ABBREVIATIONS

SHEET NUMBERING SYSTEM

MATERIALS LEGEND

C) CEILING HEIGHT DIMENSIONS ARE FROM FINISH FLOOR TO FINISH FACE OF CEILING.

OTHERWISENOTED.

D) ALL INTERIOR ELEVATIONS ARE REFERENCED FROM TOP OF FINISH FLOOR BEING EQUAL TO +0' 0".

E) ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO CONSTUCTION.

F) DIMENSIONS ARE NOT ADJUSTABLE WITHOUT APPROVAL OF AUTHORIZED REPRESENTATIVE IN WRITING.

G) MINIMUM CLEARANCE AND OTHER DISABLED ACCESS DIMENSIONAL REQUIREMENTS SHALL TAKE PRECEDENCE IN ALL CASES. NOTIFY AUTHORIZED REPRESENTATIVE OF ANY DISCREPANCIES.

H) DIMENSIONS AND GRAPHIC REPRESENTATIONS OCCURRING IN LARGE SCALED DRAWINGS SHALL TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS.

I) DIMENSION STRING TOLERANCES MAY VARY IN PRECISION. 1/8" TOLERANCE TAKES PRECEDENCE IN ALL CASES.

4. DETAILS MARKED "TYPICAL" (TYP) SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE.

5. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING OR CONSTUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR LIKE CASES OF CONSTUCTION ON THE PROJECT.

6. DETAILS MARKED AS "SIMILAR" (SIM) MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITION NOTED.

VERIFY SIMILAR DIMENSIONS OR NOTES ON THE PLANS.

7. FOLLOW ALL MANUFACTURER'S RECOMMENDED SPECIFICATIONS AND INSTALLATION PROCEDURES UNLESS OTHERWISE DIRECTED.

8. ROOF COVERINGS AND ROOFING MATERIAL SHALL BE FIRE RETARDANT AND COMPLY WITH THE UNDERWRITERS LABORATORIES, INC., CLASS "A" U.L. FIRE HAZARD.

9. FIRE RATED WALLS SHALL EXTEND FROM RATED FLOOR AND TERMINATE AT A RATED CEILING ASSEMBLY.

10. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR DIMENSIONS LOCATING FIXTURES.

11. PROVIDE ADEQUATE ANCHORAGE, BLOCKING, BACKING AND FRAMING FOR SPRINKLERS, PIPING, LIGHT FIXTURES, ELECTRICAL UNITS, HVAC EQUIPMENT, CEILING AND WALL MOUNTED EQUIPMENT (E.G. CABINETS, HANDRAILS & GUARDRAILS, AND LIGHT FIXTURES) ETC., AS REQUIRED FOR A COMPLETE INSTALLATION.

12. USE WATER RESISTANT GYPSUM WALL BOARD (W.R.) ON ALL VERTICAL FACES WHICH ARE EXPOSED TO WATER OR MOISTURE.

13. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITION ON THE JOBSITE AND AUTHORIZED REPRESENTATIVE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITION. 14.

ARCHITECTURAL SYMBOLS

2.

1.

1ST STREET NE

1ST STREET NE

REMOVE AND REPAIR EXIST SLAB TO RECEIVE NEW STAIR STRUCTURE. (SEE STRUCT DWGS)

REMOVE EXIST PORTION OF PARAPET WALL (SEE STRUCT DWGS)

1ST STREET NE

1ST STREET NE

1ST STREET NE

1ST STREET NE

1ST STREET NE

3.

SHEET NOTES:

1.

CHIP AWAY STONE CLADDING TO MATCH EXISTING STONE FINISH IN AREA SHOWN TO ALLOW FOR MOUNTING OF JUNCTION BOX.

CONCRETE WALL

ELECTRICAL DRAWINGS)

1/4" THK SATIN SS FASCIA (SEE STRUCTURAL DRAWINGS)

SILICONE SEALANT WITH BACKER ROD SATIN SS SPACER

LINE OF COFFER BELOW

3/4" THK LAMINATED, TEMPERED

OVERHEAD GLAZING UNIT WITH CERAMIC FRIT PATTERN (TYP)

SILICONE SEALANT WITH BACKER ROD

SATIN SS STRUCTURAL STRUT (SEE STRUCTURAL DRAWINGS)

LINE OF COFFER BELOW

SILICONE SEALANT WITH BACKER ROD

3/4" THK LAMINATED, TEMPERED

OVERHEAD GLAZING UNIT WITH CERAMIC FRIT PATTERN (TYP)

3/4" THK LAMINATED, TEMPERED OVERHEAD GLAZING UNIT WITH CERAMIC FRIT PATTERN (TYP)

SILICONE SEALANT WITH BACKER ROD

OF COFFER BELOW

OF COFFER BELOW SILICONE SEALANT WITH BACKER ROD

3/4" THK LAMINATED, TEMPERED OVERHEAD GLAZING UNIT WITH CERAMIC FRIT PATTERN (TYP)

SILICONE SEALANT WITH BACKER ROD

3/4" THK LAMINATED, TEMPERED OVERHEAD GLAZING UNIT WITH CERAMIC FRIT PATTERN (TYP) SILICONE SEALANT WITH BACKER ROD

THK LAMINATED, TEMPERED OVERHEAD GLAZING UNIT WITH CERAMIC FRIT PATTERN (TYP)

DRAWINGS)

SATIN SS ELECTRICAL CONDUIT FOR DOWNLIGHTS (SEE ELECTRICAL DRAWINGS)

6"Ø SATIN SS DRAIN CONNECTION

VOID IN STONE CLADDING FOR STRUCTURAL BRACKET 5"Ø SATIN SS DRAIN CONNECTION. INSERT CONNECTION PIPE INTO LARGER PIPE PRIOR TO CANOPY INSTALLATION 7 3/4"Ø VOID IN STONE CLADDING FOR STRUCTURAL BRACKET

1/2"

NOTCH BACK OF STONE CLADDING AROUND STRUCTURAL BRACKET

DRAWINGS)

SATIN SS BRACKET (SEE STRUCTURAL

STRUCTURAL SATIN SS BRACKET MOUNTING PLATE (SEE STRUCTURAL DRAWINGS)

SS MORTAR STOP

STRUCTURAL SATIN SS BRACKET (SEE STRUCTURAL DRAWINGS)

DRAWINGS)

OVERHEAD GLAZING UNIT BEYOND

STRUCTURAL SS RIB (SEE STRUCTURAL DRAWINGS)

SS PLATE COFFER BEYOND

STONE CLADDING AROUND STRUCTURAL BRACKET

RELOCATED AND MODIFIED STONE CLADDING SS GUTTER

STRUCTURAL SS (TYP, SEE STRUCTURAL DRAWINGS)

SATIN SS FASCIA (TYP, SEE STRUCTURAL DRAWINGS)

SATIN SS COFFER (TYP, SEE STRUCTURAL DRAWINGS) SILICONE SEALANT AND BACKER ROD 1/2" SATIN SS COFFER (TYP, SEE STRUCTURAL DRAWINGS)

STRUCTURAL SS (TYP, SEE STRUCTURAL DRAWINGS)

STRUCTURAL SS (TYP, SEE STRUCTURAL DRAWINGS)

SS COFFER (TYP, SEE STRUCTURAL DRAWINGS)

LAMINATED TEMPERED OVERHEAD GLAZING UNIT WITH CERAMIC FRIT PATTERN (TYP)

STRUCTURAL SS (TYP, SEE STRUCTURAL DRAWINGS) SATIN SS COFFER (TYP, SEE STRUCTURAL DRAWINGS)

GUTTER

CONTINUOUS LED LIGHT (SEE CANOPY RCP FOR LIGHT TYPE)

SS FASCIA (SEE STRUCTURAL DRAWINGS) SILICONE SEALANT (TYP)

STRUCTURAL GLAZING TAPE

STRUCTURAL SS (SEE STRUCTURAL DRAWINGS)

SS STRUCTURAL RIB (SEE STRUCTURAL DRAWINGS)

RIB PENETRATION (SEE STRUCTURAL DRAWINGS)

PLATE (SEE STRUCTURAL DRAWINGS)

FASCIA (SEE STRUCTURAL DRAWINGS)

PATCH AND REPAIR CERAMIC TILES

GRANITE STEPS (TYP) 1/2"

6" PRECAST CONCRETE PANEL

CIP BEARING WALL (REF STRUCTURE)

NOTE: DETAIL SHOWN IS AT GLASS PANEL RAILING. AT PANELESS RAILING, OMIT GLASS PANEL.

GRANITE LANDING

COMPRESSION FITTING-WITH HOLE IN GLASS PANEL (TYP. 2 PER SIDE) (OMIT AT PANELESS RAILING)

1 1/2" Ø BRONZE GUARDRAIL

1 1/2" Ø BRONZE HANDRAIL

2 1/2" Ø BRONZE POSTS

TEMPERED LAMINATED GLASS TYP. (OMIT AT PANELESS RAILING)

1/2" SETTING BED

1/2 Ø 5 1/2" SS DOWEL @ EACH TREAD (BOTH SIDES), TYP

NOTE: DETAIL SHOWN IS AT GLASS PANEL RAILING. AT PANELESS RAILING, OMIT GLASS PANEL.

1" Ø BRONZE STAND-OFF

1 1/2" Ø BRONZE HANDRAIL 1 1/2" Ø BRONZE GUARDRAIL

1/2 Ø 5 1/2" SS DOWEL @ EACH TREAD (BOTH SIDES), TYP 2-1/2" Ø BRONZE POSTS

TEMPERED LAMINATED GLASS TYP. (OMIT AT PANELESS RAILING)

NOTE:

DETAIL SHOWN IS AT GLASS PANEL RAILING. AT PANELESS RAILING, OMIT GLASS PANEL.

COMPRESSION FITTING-WITH HOLE IN GLASS PANEL (TYP. 2 PER SIDE) (OMIT AT PANELESS RAILING

1 1/2" Ø BRONZE GUARDRAIL

1 1/2" Ø BRONZE HANDRAIL. RETURN HANDRAIL TO FLOOR

1/2" TEMPERED LAMINATED GLASS TYP. (OMIT AT PANELESS RAILING) 2 1/2" Ø BRONZE POSTS

PATCH AND REPAIR CERAMIC TILES AS REQ'D

1/2" GRANITE PAVER APRON IN 1" SETTING BED

NOTE: REPAIR AND REPLACE EXISTING CEILING AS NECESSARY. ALUM EXTRUSION VERIFY CONDITIONS ABOVE CLNG TO CONFIRM ATTACHEMENT METHODS

RELOCATED STONE CLADDING

ELECTRICAL CONDUIT FOR SECURITY CAMERA (SEE ELECTRICAL DRAWINGS)

CONCEALED SS LINTEL (SEE STRUCTURAL DRAWINGS)

CONCRETE LINTEL (SEE STRUCTURAL DRAWINGS)

CONCRETE SURFACE TO HAVE FORMBOARD FINISH TO MATCH EXISTING SIZE, ORIENTATION, AND PATTERN

BI-FOLD PAINTED ALUM SECURITY GATE. PAINT COLOR TO BE METRO BROWN (IN CLOSED POSITION)