Page 1

CB0307

Monitor portátil para monitoramento de clima para aplicações agrícolas. TNHY

Product

Model: TNHY series

Product

Origin: China

Product Description: ISO9001 certification Weather Station test 9 parameters.Can be connected with computer.

About Products Product introduction: Hand-held Agricultural Weather Monitor can test temperature, humidity, illuminance, conductance, PH, CO2 concentration, dew point, soil temperature, soil moisture, wind speed, wind direction and other agricultural environmental parameters. It is widely used in protected agriculture, forestry, horticulture, animal husbandry, and other fields. Characteristics: 1. Computer software has powerful data processing functions for data statistics, analysis, display and querying. It can form curve according to collected datum, visual display. It can also store collected datum to EXCEL format, user-friendly to save and process datum. Software can be upgraded freely forever. 2. Probes have the uniformity; different probes can be connected to any sensor interface. 3. With 64 channels, test at the same time, probes are unlimited in the range of capacity. 4. Can choose testing parameters by yourself according to needs, sampling interval time of each sensor can be set separately 5. Large LCD display, touch key, smart and portable, easy to operate. 6. One-button switch, can record both manually and automatically 7. Can connect with computer to upload, process, backup datum. 8. Both AC and DC available 9. With powerful data storage function, can store up to 120000groups of datum 10. Datum saved in machine won mot lose when power off

Biosystems Comércio, Imp. e Exp. de Equip. para Laboratório Rua Theodoro Makiolka, 885, Santa Cândida, Curitiba – PR - CEP: 82640-010. E-commerce: www.biosystems.com.br E-mail: comercial@biosystems.com.br Pág.: 1 - 2


CB0307

Monitor portátil para monitoramento de clima para aplicações agrícolas. TNHY Technical parameters: Testing index Parameter range:-40℃-80℃ Temperature accuracy:±0.4℃ resolution:0.1℃ Humidity

Dew Point Light Intensity PAR radiation Wind Direction

range:0-100%RH accuracy:±3%RH resolution:0.1%RH range:-40℃-120℃ accuracy:±0.4℃ resolution:0.1℃ range:0-200000Lux accuracy:±20Lux resolution:1Lux range:1-2,700µmolm-2s-1 (400-700nm) accuracy:±1% resolution:1µmolm-2s-1 range:0-359° accuracy:±1°

range:0-45m/s Wind Speed accuracy:±(0.3+0.03V) m/s

Testing index Rainfall

CO2

Soil Temperature Soil Moisture

Parameter range:0-4mm/min accuracy:±0.4mm resolution:0.1mm range:0-2000PPM Volatility:±( 40PPM + Measurements×3%) resolution:1PPM range:-20℃-100℃ accuracy:±0.5℃ resolution:0.1℃; range:0-100% accuracy:2% resolution:0.1%

PH

PH range: pH:0-14 PH accuracy: ±0.1

Conductance

range: 0-20mS/cm Conductance accuracy: ±1%

Barometric pressure (optional)

range:300-1100Hpa accuracy:±1Hpa

Model difference: TNHY-4: Temperature, humidity, illuminance, CO2 concentration. TNHY-5: Temperature, humidity, illuminance, PAR, CO2 concentration. TNHY-6: Temperature, humidity, illuminance, CO2 cencentration, soil temperature, soil moisture. TNHY-7: Temperature, humidity, illuminance, PAR, CO2 concentration, soil temperature, soil moisture. TNHY-9: Temperature, humidity, illuminance, PAR, CO2 concentration, soil temperature, soil moisture, soil PH, soil EC conductance. TNHY-10: Temperaturem, humidity, illuminance, PAR, CO2 concentration, soil temperaturem, soil moisture, wind direction, wind speed, rainfall. TNHY-11: Temperature, humidiity, illuminance, PAR, CO2 concentration, soil temperature, soil moisture, soil PH, soil PH, soil EC conductance, wind direction, wind speed, rainfall.

Biosystems Comércio, Imp. e Exp. de Equip. para Laboratório Rua Theodoro Makiolka, 885, Santa Cândida, Curitiba – PR - CEP: 82640-010. E-commerce: www.biosystems.com.br E-mail: comercial@biosystems.com.br Pág.: 2 - 2