NeonatalHeartRateDetectionUsing AuxiliaryOpticalSystem MridulaGarimella,T.V.HimajaSree,AnushaBandari,IbrahimPatel

df .re

s.i n

Abstract: Ǧ Fetal heart rate (FHR) monitoring is a proven means of assessing fetal health during the antenatalperiod.Currently,theonlywidelyavailableinstrumentationforproducingthesedataisbasedon Doppler ultrasound, a technology that is unsuitable for longǦterm use. For nearly a century, it has been known that the fetal Photoplethysmography (FPPG) can be detected using electrodes placed on the maternalabdomen.Thepaperdescribesthedesign,constructionanduseofacompact,longǦtermrecorder of three channels of 24 h antenatal trans abdominal data. Preliminary use of the recorder in around 400 short recording sessions demonstrates that FHR records of equivalent quality to those from Doppler ultrasound based instruments can be extracted from such data. The success of FHR derivation is, on average, around 65% of the recording period from around 20 weeks gestation (although this figure is reducedfromaround2832weeks,andthesuccessratesexhibitawiderangewhenindividualsubjectsare considered).Theseresultsdemonstratethatthetechniqueoffers,notonlyameansofacquiringlongǦterm FHRdatathatareproblematictoobtainbyothermeans,butalsoamorepatientǦfriendlyalternativetothe Dopplerultrasoundtechnique.

as

Keywords:ǦAutonomicnervoussystem,ECG,Heartratevariability,FetalPhotoplethysmography,Doppler ultrasound,AdaptiveNoiseCancelling(ANC).

1. Introduction

w

.e d

lib .

Nowadays there is a growing research interest in biomedical optics which utilizes the light to probe structure and function in biomedicine and leads to several noninvasive and nonionized diagnostic and therapeutic methods such as laser surgery, photodynamic therapy, laser Doppler flowery (LDF), and Photoplethysmography (PPG). To understand the fundamentals of such methods, it is necessary to investigate the phenomena of photonǦtissue interaction. Photoplethysmography (PPG) is in this day and ageextensivelyuseandhasbeenacceptedbyphysiciansbecauseofitssimpledesignandrelativelylowcost perexamination.APPGsystemwithNIRopticalsensorscanmeasurethe She is pursuing her Bachelor’s degree in BME Dr B. V. Raju Institution of Technology Narsapur, Medak,A.P. 2. She is pursuing her Bachelor’s degree in BME Dr. B. V. Raju Institution of Technology Narsapur, Medak,A.P. 3. She is pursuing her Bachelor’s degree in BME Dr .B. V. Raju Institution of Technology Narsapur, Medak,A.P. 4. Assoc.Prof.DeptofECE.Dr.B.V.RajuInstitutionofTechnologyNarsapur,Medak,A.P.

w

w

1.

bloodvolumechangesintheskinsurfacelayersbyregisteringtheattenuationchangeinthenearinfrared spectrum.ItsbiophysicalprincipleisbasedonthefactthatthereisastrongcontrastinabsorptionofNIR light between the bloodǦfilled vessels and the ambient bloodless tissue. So through detection of the light remitted from the skin, it is possible to measure the blood volume change of the skin. The PPG system provides a simple and noninvasive method to detect venous diseases at early stage through certain functionaltestslikeVOT(VenousOcclusionTest)andMPT(MusclePumpTest).OnedisadvantageofPPG isthatitcanonlymeasureonesmallareaatonetimeandthusverydifficulttogetaspatialdistributionof the blood volume change of the skin. Because of the spatial variation of the circulation system, it is necessarytogetamappingofthevenoushemodynamics.MultichannelPPGdevicehasbeendevelopedto monitor the skin perfusion at different sites, but it introduces more problems with sensor attachment, whichmakesthetestpersonuncomfortableandintroducingmoremovementartifacts.Alsoahighspatial

ZZZWHFKQRIRUXPFR

3DJHRI

ZZZDVGIUHVLQ


3URFHHGLQJVRIWKH,QWO&RQIRQ,QQRYDWLYH7UHQGVLQ(OHFWURQLFV&RPPXQLFDWLRQDQG$SSOLFDWLRQV,&,(&$

resolution is impossible with multichannel PPG because the probe size of PPG is often more than 1cm 2. Another disadvantage of PPG is that the test person has to be measured contactly, which restrict its applicationtosomeclinicalsituationsuchasmonitoringthewoundhealingprocess.Inthispaper,anew noninvasive and nonǦcontact method called Photoplethysmography Imaging (PPGI) is presented. A PPG ImagerwhicharrangesahighǦqualityCCDcamerawithauxiliaryopticalsystemcombinesthefeaturesof both classical PPG measurement and CCD imaging. It can visualize the structure of skin vessels and evaluate the venous hemodynamics as well as the arterial pulsation. PPGI avoids the time –consuming scanning by using CCD as an array of photon detectors so that it can monitor the dynamic changes of dermalperfusionondifferentpartsofskinsurfacesimultaneouslyandflexiblyasshowninthefigure1.

II.WorkingPrinciple

w

w

w

.e d

lib .

as

df .re

s.i n

Photoplethysmography(PPG)isasimpleandlowǦcostopticaltechniquethatcanbeusedtodetectblood volumechangesinthemicrovascularbedoftissue.ItisoftenusednonǦinvasivelytomakemeasurements at the skin surface. The PPG waveform comprises a pulsatile ('AC') physiological waveform attributed to cardiac synchronous changes in the blood volume with each heartbeat, and is superimposed on a slowly varying ('DC') baseline with various lower frequency components attributed to respiration, sympathetic nervoussystemactivityandthermoregulation.AlthoughtheoriginsofthecomponentsofthePPGsignal arenotfullyunderstood,itisgenerally 

 Fig.1:HardwaresetupforOFHRdetection.

acceptedthattheycanprovidevaluableinformationaboutthecardiovascularsystem. An alternative to ultrasound is using the fetal electrocardiogram (FECG). Invasive FECG uses a scalp electrodeandremainsreservedtopreǦdeliveryconditions.Ontheotherhand,nonǦinvasiveFECGgenerally needs 3Ǧ4 leads, which renders the procedure more complex from a practical perspective where many electrodesneedtoretainperfectohmiccontactwiththesubject'sbody.TheFECGisgenerallyutilizedlater inpregnancyduetoitslowsignalǦtonoiseratio(SNR),i.e.betweenthe28thand30thweekofgestation.It is worth mentioning that commercial devices operating on nonǦinvasive FECG are not available at this moment. However, these techniques are expensive, require a high optical power and are difficult to implementduetosizeandpowerconsumptionlimitations.

ZZZWHFKQRIRUXPFR

3DJHRI

ZZZDVGIUHVLQ


3URFHHGLQJVRIWKH,QWO&RQIRQ,QQRYDWLYH7UHQGVLQ(OHFWURQLFV&RPPXQLFDWLRQDQG$SSOLFDWLRQV,&,(&$

III.HardwareDesignforPPGMeasurementofFetusHeartRate

lib .

as

df .re

s.i n

AconventionalreflectancePPGsensorconsistsofanLEDunitandphotodetectorinparallelconfiguration. Since LEDs emit light in a circular pattern, the detected light represents a fraction of the total reflected lightemittedtowardthephotodetector.Toincreasetheincidentlight,weplacedthreeLEDssymmetrically aroundthephotodetector(seeFig.2and3).LightemittedfromeachLEDhaditsowncircularpattern,and aportionofthelightfromeachLEDoverlappedatthephotodetector.Theoutputsignalfromthesensor was converted into a voltage and amplified, then filtered with a band pass of 0.05–10 Hz to separate the pulsatileaccomponent,andfilteredwithalownjpasscutoffat0.1Hztoseparatethedccomponent.Theac anddcsignalsweredigitizedat400Hzusingthemicroprocessor. 



w

w

w

.e d

Fig.2:BlockdiagramfortheproposedPPGmeasurementsystemthatincludes anadaptivelightintensitycontrolfunctionusingdccomponents.

 Fig.3:ConceptualdiagramsoftheproposedPPGsensorwiththreelightsources. (a)Frontalview.(b)Transverseview.

ZZZWHFKQRIRUXPFR

3DJHRI

ZZZDVGIUHVLQ


3URFHHGLQJVRIWKH,QWO&RQIRQ,QQRYDWLYH7UHQGVLQ(OHFWURQLFV&RPPXQLFDWLRQDQG$SSOLFDWLRQV,&,(&$

III.Procedure TheChallengeindesigningFHR Themainchallengeistodesignanddevelopalowpoweropticalfetalheartrate(FHR)monitor.Thesignal of interest is the photoplethysmogram (PPG), which is generated when a beam of light is modulated by blood pulsations. The light intensity is modulated by the mother as well as fetal blood circulations, producing a mixed signal which needs to be separated via advanced digital signal processing (DSP) techniques Solution is as the input power of the incident radiation leads to a lower SNR, the excitation signalisachoppedlightbeamandsynchronousdetectionisperformed.OpticalFetalHeartRateDetection System.

df .re

s.i n

Fetalheartrate(FHR)detectionistheprimarymethodologyforantenataldeterminationoffetalwellǦbeing, assistingintheidentificationofpotentialhazardssuchashypoxiaanddistresstothefetus.Theexpected outcome of this early detection is a reduced risk of fetal morbidity and mortality. Currently FHR can be detectedbyusingDopplerultrasound,wherethestandardpreǦdeliverytestoffetalhealthisthefetalnonǦ stress test (NST). These tests are routinely performed at the hospital, generally with continuousǦwave instruments. Although current ultrasonic FHR detectors are becoming less expensive and bulky, accurate sensoralignmentandsomedegreeofexpertisearestillrequiredtocorrectlyoperatethem.Moreover,they aresensitivetomotionartifactandfinallycompletesafetyoflongǦtermexposureofthefetustoultrasound waveshasyettobeestablished,thereforeonlyshortǦtermtestingisactuallypracticed.

lib .

as

An alternative to ultrasound is using the fetal electrocardiogram (FECG). Invasive FECG uses a scalp electrodeandremainsreservedtopreǦdeliveryconditions.Ontheotherhand,nonǦinvasiveFECGgenerally needs 3Ǧ4 leads, which renders the procedure more complex from a practical perspective where many electrodesneedtoretainperfectohmiccontactwiththesubject'sbody.TheFECGisgenerallyutilizedlater inpregnancyduetoitslowsignalǦtonoiseratio(SNR),i.e.betweenthe28thand30thweekofgestation.It is worth mentioning that commercial devices operating on nonǦinvasive FECG are not available this moment.

w

w

.e d

Morerecently,opticalmethods,stillattheresearchstage,havebeenproposedwherehalogenandtungsten by a photomultiplier. In these works, the emphasize was on trans abdominal monitoring of fetal arterial blood oxygenation for pulseǦoximetry and by the same means FHR, with wavelengths in the 675Ǧ700 nm and 850Ǧ900 nm range to get optimum results. However, these techniques are expensive, require a high opticalpowerandaredifficulttoimplementduetosizeandpowerconsumptionlimitations.OpticalFetal HeartRateDetectionSystem.

w

Inthiswork,alowǦpoweropticaltechniqueisproposedbasedonthePPGtononǦinvasivelyestimatethe FHR.AbeamofLEDlight(<68mW)isshonetothematernalabdomenandthereforemodulatedbythe bloodcirculationofbothmotherandfetuswhereasmaximumpenetrationisachievedatawavelengthof 890 nm. This mixed signal is then processed by an adaptive filter with the maternal index finger PPG as referenceinput.TheFigureshowstheopticalfetalheartratedetection(OFHR)systemblockdiagram The fetal probe (primarysignal) is attached tothematernal abdomen using aVelcro belt to hold theIRǦ LEDandphotodetector,separatedby4cm.Thereferenceprobeisattachedtothemother’sindexfingeras generallypracticedinpulseoxymetry.AstheselectedIRǦLEDcouldonlyemitamaximumopticalpowerof 68 mW, the OFHR system operates with an optical power less than the limit of 87 Mw specified by the International Commission on NonǦIonizing Radiation Protection (ICNIRP). In order to modulate the IRLED, the modulation signal is generated at a frequency of 725 Hz using software subroutine through a counterport(NIǦUSB9474)totheLEDdriver. The diffused reflected light from the maternal abdomen, detected by the lowǦnoise photo detector, is denotedasI(M1,F),whereM1andFdenotethecontributiontothesignalfromthemotherabdomenand

ZZZWHFKQRIRUXPFR

3DJHRI

ZZZDVGIUHVLQ


3URFHHGLQJVRIWKH,QWO&RQIRQ,QQRYDWLYH7UHQGVLQ(OHFWURQLFV&RPPXQLFDWLRQDQG$SSOLFDWLRQV,&,(&$

fetus,respectively.AlowǦnoise(6nV/Hz1/2)transimpedanceamplifierisutilizedtoconvertthedetected current to avoltage level.The reference probe (mother’s index finger) consistsof an IRǦLED and a solidǦ statephotodiodewithanintegratedpreamplifier.ThesignalfromthisprobeisdenotedasI(M2),where M2referstothematernalcontribution.Synchronousdetectionisnotrequiredatthischannelasthefinger photoplethysmogramhasahighsignaltonoiseratio(SNR).

V.AnOpticalFHRDetectionSystem

s.i n

Our research team proposed a lowǦpower optical technique based on the photoplethysmogram (PPG) signal,whichisgeneratedwhenabeamoflightismodulatedbybloodpulsations,tononinvasivelyestimate theFHR.ThedoctorortechnicianshinesabeamofLEDlight(lessthan68mW)atthematernalabdomen, modulatedbythebloodcirculationofthemotherandfetus.Maximumlightwavepenetrationisachieved at a wavelength of 890 nm. This mixed signal can be processed by an adaptive filter using digital signal processingwiththematernalindexfingerPPGasareferenceinput,Figure1:OFHRsystemblockdiagram showingthehardwaremoduleshavebeenimplementedinembeddedsystems.

df .re

TheteamdevelopedtheopticalFHR(OFHR)detectionsystemusingembeddedsystemsgraphicalsystem designsoftwareandNIhardware.IntheOFHRsystem,reducingtheinputpoweroftheincidentradiation leadstoalowersignalǦtoǦnoiseratio(SNR),andtheexcitationsignalisachoppedlightbeam.

as

At the receiver side, lowǦnoise amplification and synchronous detection ensures conservation of the information with minimum noise power. A 24Ǧbit NI USBǦ 9239 analogǦtoǦdigital converter (ADC) minimizes the effects of quantization noise. Once digitized, the signal is processed via adaptive noise canceling(ANC)techniquestoextractthefetalPPGfromthemixedsignal.

.e d

lib .

Weattachedthefetalprobe(primarysignal)tothematernalabdomenusingaVelcrobelttoholdtheIRǦ LEDandphotodetectorseparatedby4cm.Weattachedthereferenceprobetothemother’sindexfinger. Because the selected IRǦLED could only emit a maximum optical power of 68 mW, the OFHR system operateswithanopticalpowerlessthanthelimitof87mWspecifiedbytheInternationalCommissionon NonǦIonizingRadiationProtection(ICNIRP).

VI.ResultsandDiscussion

w

w

w

To modulatethe IRǦLED, the modulation signal is generated at a frequency of 725 Hz using the software subroutine through a NI 9474 counter port to the LED driver. As seen in Figure 4, the diffused reflected lightfromthematernalabdomen,detectedbythelowǦnoisephotodetector,isdenotedasI(M1,F)sothat M1andFdenotethecontributiontothesignalfromthemother’sabdomenandfetus,respectively.Filtering and an adaptive noise cancelling (ANC) algorithm. The team used Lab View to implement the entire algorithm and part of the instrument. After preprocessing and applying the ANC algorithm, Lab View displays results for the fetal signal and the FHR. Figure 4 illustrates the laboratory prototype and the graphical user interface of the OFHR system and presents the maternal index finger PPG (top), the abdominal PPG (middle),and the estimatedfetal PPG (bottom).Figure 5 and 6: The laboratory prototype andthegraphicaluserinterfaceoftheOFHRsystem. 

ZZZWHFKQRIRUXPFR

3DJHRI

ZZZDVGIUHVLQ


s.i n

3URFHHGLQJVRIWKH,QWO&RQIRQ,QQRYDWLYH7UHQGVLQ(OHFWURQLFV&RPPXQLFDWLRQDQG$SSOLFDWLRQV,&,(&$



df .re



w

w

w

.e d

lib .

as

Fig.4:GraphicaluserinterfaceofOFHRsystem.Systemintegritycheckmenu. 

 Fig.5:GraphicaluserinterfaceofOFHRsystem



. Fig.6:FHRtracemenu.

ZZZWHFKQRIRUXPFR

3DJHRI

ZZZDVGIUHVLQ


3URFHHGLQJVRIWKH,QWO&RQIRQ,QQRYDWLYH7UHQGVLQ(OHFWURQLFV&RPPXQLFDWLRQDQG$SSOLFDWLRQV,&,(&$

lib .

as

df .re

s.i n

Figure 7 illustrates the three selectable displays, including digital synchronous or lockǦin amplifier (LIA), adaptive noise cancelling (ANC), and heart rate trace. Figure 7: The three selectable displays, including digitalsynchronous or lockǦin amplifier(LIA), adaptive noise cancelling (ANC),and heart rate trace. The purposeofthefirsttwodisplaysistoassistdevelopment,andthethirddisplayindicatesFHRvaluesversus time.Theusercaneitherviewthedatalineorsaveitforfurtheranalysis.Afterdevelopment,wetestedour system’s functionality with a total of 24 data sets from six subjects at 37 ±2 gestational weeks from the UniversityKebangsaanMalaysiaMedicalCentre.TheUniversityEthicalCommitteereviewedandapproved thestudy,andallpatientswhoparticipatedprovidedwrittenconsent.Allfetusesinthisstudywerefound to be healthy by an obstetrician and born without complication. In our study, we obtained a correlation coefficientof0.97(pǦvaluelessthan0.001)betweenopticalandultrasoundFHRwithamaximumerrorof4 percent.Clinicalresultsindicatethatpositioningtheprobeoverthenearestfetaltissues,notrestrictedto theheadorbuttocks,improvessignalqualityanddetectionaccuracy.Canbedetectedbyaphotodetector. Bloodabsorbsmostlymorelightthanthesurroundingtissuedoes,andthereforeareductionoftheamount ofbloodgivesanincreaseintheintensityofthedetectedlight.Thewavelengthanddistancebetweenlight source and photo detector also determines the depth of penetration (69). Green light is suitable for measurementofsuperficialskinbloodflow,andinfrared(IR)ornearIRisbetterformeasurementsofthe deeptissue(muscle)bloodflow(73). 

.e d





x x

VII.Advantages

w

LowPowerRequirement. LessExpensive. CommerciallyAvailable. MoreAccurateThanOtherFHRMeasurementTechniques. SmallComponents.

w

x x x x x

w

Fig.7:ANCBlockdiagram

VIII.Disadvantages HighlySophisticatedTechnology. ChanceofTroubleShootingisVeryHigh.

IX.Conclusion OurresearchteamdevelopedanovelOFHRdetectionsystemusinglowǦcostandlowǦpowerIRlightanda commercially available silicon detector. With embedded systems, we rapidly and easily implemented the digitalsynchronousdetectionandadaptivefilteringtechniques.WemeasuredFHRresultswithacceptable

ZZZWHFKQRIRUXPFR

3DJHRI

ZZZDVGIUHVLQ


3URFHHGLQJVRIWKH,QWO&RQIRQ,QQRYDWLYH7UHQGVLQ(OHFWURQLFV&RPPXQLFDWLRQDQG$SSOLFDWLRQV,&,(&$

accuracy compared to the standard method of detection (Doppler ultrasound). Moreover, due to the noveltyofoursolution,weareintheprocessoffilingapatentforitscommercialuse.

FutureDevelopment ResearchersaretakingplacetoachievemoreefficientanderrorlessFHRbyapplyingNanotechnology.

X.References

8) 9) 10)

11) 12) 13) 14)

s.i n

df .re

7)

as

6)

lib .

5)

.e d

4)

w

3)

w

2)

GanKokBeng,EdmondZahedi,andMohd.AlauddinMohd.Ali,UniversityKebangsaanMalaysia, FacultyofEngineering C.D.Kurth,J.M.Steven,D.Swedlow,â&#x20AC;&#x153;Newfrontiersinoximetryâ&#x20AC;?AmJAnesthesiolvol23,pp.169ÇŚ 175,1996. G.A.Dildy,J.A.Thorp,J.D.YeastandS.L.Clark,"Therelationshipbetweenoxygensaturationand pH in umbilical blood: implications for intrapartum fetal oxygen saturation monitoring," Am J ObstetGynecolvol.175,no.3Pt1,pp.682ÇŚ687,1996. J.L.ReussandD.Siker,â&#x20AC;&#x153;Monitoringsiteandwavelengthselectionforfetalpulseoximetry,â&#x20AC;?Assoc. Advanc.Med.Instr.AnnualMeeting,June2001. A.K.Luttkus,J.H.Stupin,M.PorathandJ.W.Dudenhausen,"EvaluationOfsignalqualityofanew fetalpulsoximetrysystem(OBSÇŚ500).Arecentdevelopmentofafetaloxisensorpositionedonthe fetalback,"JPerinatMedvol.29,no.S1,pp.251,2001. T.L.Rusch,R.SankarandJ.E.Scharf,"Signalprocessingmethodsforpulseoximetry,"ComputBiol Medvol.26,no.2,pp.143ÇŚ159,1996. D. E. Bahr and J. L. Reuss, â&#x20AC;&#x153;Method and Apparatus for Processing a Physiological Signal,â&#x20AC;? U. S. Patent6,339,715B1,January15,2002. L.R.RabinerandB.Gold,TheoryandApplicationofDigitalSignalProcessing.EnglewoodCliffs, NJ:PrenticeÇŚHall,1975. S.Palreddy,â&#x20AC;&#x153;SignalProcessingAlgorithms,â&#x20AC;?inDesignofPulseOximeters,J.G.Webster,Ed.Bristol andPhiladelphia:InstituteofPhysicsPublishing,1997,pp.124ÇŚ158. S.Nioka,M.Izzetoglu,T.Mawn,M.J.Nijland,D.A.Boas,andB.Chance,â&#x20AC;&#x153;Fetaltransabdominalpulse oximeterstudiesusingahypoxicsheepmodel,â&#x20AC;?J.MaternalFetalNeonatalMed.,vol.17,no.6,pp. 393â&#x20AC;&#x201C;399,2005. B. Chance, â&#x20AC;&#x153;Transabdominal examination monitoring and imaging of tissue,â&#x20AC;? U.S. Patent 2005/0038344A1,Feb.17,2005. A.M.Vintzileos,S.Nioka,andM.Lake,â&#x20AC;&#x153;Transabdominalfetalpulseoximetryusingnearinfrared spectroscopy,â&#x20AC;?Amer.J.Obstet.Gynaecol.,vol.192,pp.129â&#x20AC;&#x201C;133,2005. Zourabian,B.Chance,N.Ramanujam,R.Martha,andA.B.David,â&#x20AC;&#x153;TransÇŚabdominalmonitoringof fetalarterialbloodoxygenationusingpulseoximetry,â&#x20AC;?J.Biomed.Opt.,no.5,pp.391â&#x20AC;&#x201C;405,2000. E.ZahediandK.B.Gan,â&#x20AC;&#x153;Applicabilityofadaptivenoisecancellationtofetalheartratedetection usingphotoplesthysmography,â&#x20AC;?Comput.Biol.Med.,vol.38,no.1,pp.31â&#x20AC;&#x201C;41,2008.

w

1)

ZZZWHFKQRIRUXPFR

3DJHRI

ZZZDVGIUHVLQ

Icieca0007  
Read more
Read more
Similar to
Popular now
Just for you