DFC Drainage Submersible pumps for wastewater with entrained solids Applications Pumping of sewage with suspended solids and filaments. Emptying of sumps, septic tanks and wastewater discharge tanks. Draining of flooded excavations and marshy ground. Water display, fountains.

Equipment With 5 m power cord. Single-phase, with built-in automatic reset overload protection and capacitor box with on/off switch. Three-phase, overload protection to be provided by user (installed in the control box).

Materials Pump body and delivery seal in cast iron. (coated with polybutadiene varnish by electrophoresis at 180°C). Impeller, suction flange, support feet, shaft extension and motor casing in AISI 304 stainless steel. Mechanical seal in carbon/ceramic/ nitrile rubber. O-ring in nitrile rubber.

Limitations Maximum immersion depth: 5 m. Maximum liquid temperature: 50 °C with fully submerged pump; 25 °C with partially submerged pump. Passes solids up to: 50 mm.

Motor Squirrel cage motor in a dielectric, cooled with non-toxic oil, which ensures the lubrication of the ball bearings and more efficient cooling. IP 68 protection.

Dimensions and weights Model

A

B

C

D

E

F

G

H

I

J

kg

DFC 110

486

239

120

183

343

253

74

114

181

Rp 2

27

DFC 150

486

239

120

183

343

253

74

114

181

Rp 2

27

Performance curves at 2900 rpm

F G

H

D A E

J

C I B

DFC 110 DFC 150

I (A) 1~ 230 V 8,5

230 V

P1 (kW) 3~

P2

l/min

50

100

200

300

400

500

600

700

m3/h

3,0

6,0

12

18

24

30

36

42

16

14,5

12,5

10,5

8,5

6,5

5

20

18,5

16

14

12

10

8

µF 400 V

5,7

3,3

6,6

3,8

1~

3~

(kW)

(HP)

1,75

1,75

1,1

1,5

2,2

1,5

2

35

mwc

Model

5,5

TEC 6057EN 09/09

Hydraulic performance table


DFC