Page 1

TECHNICAL CHARACTERISTICS

HMT/P TRANSMITTING UNITS CHARACTERISTICS

IF frequency IF input level Output power and frequency range Spurious attenuation Frequency stability Power supply

1000 ÷ 1400 MHz synthesized, 125 KHz step or (optional) 70 MHz -5 ÷ +5 dBm (50 Ω) see table in previous page > 60 dBc standard ± 35 ppm, optional ± 5 ppm or ± 10 ppm (-20°÷ +50°C) 24 VDC ± 10%

RPT REPEATERS CHARACTERISTICS

RF input level lst IF frequency 2nd IF frequency Receiver noise figure Image frequency suppression Output power and frequency range Spurious attenuation Frequency stability Power supply

-35 ÷ 80 dBm (50 Ω) 1000 ÷ 1400 MHz 70 MHz ≤ 8 dB (5 dB typ.) ≥ 65 dB see table in previous page > 60 dBc standard ± 35 ppm, optional ± 5 ppm or ± 10 ppm (-20°÷ +50°C) 24 VDC ± 10% (using AL/HM power supply unit)

HMR/P RECEIVING UNITS CHARACTERISTICS

RF input level lst IF frequency 2nd IF frequency IF output level Receiver noise figure Image frequency suppression Frequency stability Power supply

-35 ÷ 80 dBm (50 Ω) 1000 ÷ 1400 MHz 70 MHz - 40 ÷ +5 dBm ≤ 8 dB (5 dB typ.) ≥ 65 dB standard ± 35 ppm, optional ± 5 ppm or ± 10 ppm (-20°÷ +50°C) 24 VDC ± 10%

GENERAL CHARACTERISTICS

Outdoor units operating temperature range Indoor units operating temperature range Operating humidity range

OPTIONS FOR MMT/P AND DMT/P

70/IF AMT 2/T AMT 2/R

OPTIONS FOR HMT/P, HMR/P AND RPT

/IN /70 HFS 10 HFS 05

Passion for

FM & TV

Broadcasting

-20 ÷ +50 °C -5 ÷ +45 °C ≤ 95 % 70 MHz IF output (for MMT/P) or input (for DMT/P) Additional audio sub-carrier for MMT/P and for HMT/P 2 Additional audio sub-carrier for DMT/P and for HMR/P 2 Indoor version 70 MHz IF input (for HMT/P) or output (for HMR/P) High frequency stability < 10 ppm High frequency stability < 5 ppm Features and specifications subject to change without notice.

Portable Microwave Analog TV Links

PORTABLE VERSION DB Elettronica Telecomunicazioni SpA - Riviera Maestri del Lavoro 20/1 - 35127 Padova - Italy ph +39 049 8700588 fax +39 049 8700747 - www.dbbroadcast.com - sales@dbbroadcast.com

MLP Series


Portable Microwave Analog TV Links MLP Series

TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS

• 1 Video and up to 4 Audio. The MLP Series microwave links are designed to carry 1 video and up to 4 highquality 15 kHz analog audio programs. • RF converters. The RF up-converters (HMT/P) and down-converters (HMR/P) are fitted into outdoor waterproof boxes suitable to be fixed to a tripod head. • Control units to RF units cable interconnection. The outdoor RF units are connected with the indoor IF • Easy IF repeater assembly. A non-demodulated IF repeater assembly is obtained using a receiving downchannel: the IF channel selective filters in the IF repeater unit allow to clean the received spectrum from any interference for a good repeater working also in congestioned RF spectrum conditions. • Synthesized RF channels. Easy and fast RF frequency channel setting using a 125 KHz step digital low• Data channel. High capacity data channel is available using the baseband in/out facility or a dedicated data

1W 4W 8W

4.2 - 4.8 GHz 4.2 - 4.8 GHz 4.2 - 4.8 GHz

HMT/P 5-15/1 HMT/P 5-15/4 HMT/P 5-15/6 HMT/P 5-15/8

RPT 5-15/1 RPT 5-15/4 RPT 5-15/6 RPT 5-15/8

1W 4W 6W 8W

5.4 – 15.0 GHz 5.4 – 15.0 GHz 5.4 – 15.0 GHz 5.4 – 15.0 GHz

0.1 W 0.3 W 1W

22.5 - 24.5 GHz 22.5 - 24.5 GHz 22.5 - 24.5 GHz

IF up-converter and amplifier IF up-converter and amplifier IF up-converter and amplifier IF up-converter and amplifier

RPT 24/01 RPT 24/03 RPT 24/1

Frequency range 1.3 - 2.7 GHz 4.2 - 4.8 GHz 5.4 – 15.0 GHz 22.3 - 24.5 GHz

OVERALL CHARACTERISTICS

Baseband amplitude frequency response Video amplitude frequency response Group delay in video band Differential gain Differential phase Video Signal to Noise ratio Audio channels frequency response Audio channels THD (at 400 Hz) Audio Signal to Noise ratio

MMT/P IF MODULATOR CHARACTERISTICS

IF frequency Modulation Frequency deviation IF output level IF+ 24 VDC output connector Modulation linearity (IF ± 8 MHz) Video input level Video input connector Video preemphasis (bypassable) Audio input level (100 kHz pp deviation) Audio input connector Audio pre-emphasis (bypassable) Audio subcarrier frequencies Power supply

1000 ÷ 1400 MHz synthesized, 125 KHz step or (optional) 70 MHz CCIR 405/1 ± 8 MHz pp - 5 dBm to + 2 dBm (50 Ω) N female ≤0.5 % 1 Vpp ± 1 dB (75 Ω unbal) BNC C.C.I.R. 625 lines -6 ÷ + 12 dBm (600 Ω bal/unbal) XLR female 50/75 µS 7020, 7500, 8065, 8590 MHz single phase AC 110/220/240 ± 15%, 50/60 Hz

DMT/P IF DEMODULATOR CHARACTERISTICS

IF frequency IF input level IF+ 24 VDC input connector Video de-emphasis (bypassable) Video output level Video output connector Audio output level (100 kHz pp deviation) Audio de-emphasis (bypassable) Power supply

1000 ÷ 1400 MHz synthesized, 125 KHz step or (optional) 70 MHz -40 ÷ + 5 dBm (50 Ω) N female C.C.I.R. 625 lines 1 Vpp ± 1 dB (75 Ω unbal) BNC -6 ÷ + 12 dBm (600 Ω bal/unbal) 50/75 µS single phase AC 110/220/240 ± 15%, 50/60 Hz

• Full monitoring. A front panel digital multimeter complete with alarm leds allows to check the audio and video levels, RF output power, RF received level, PLL lock and the squelch status. • Meets or exceeds all the international standards for safety and electrical specifications.

MMT/P

Frequency range 1.3 - 2.7 GHz 1.3 - 2.7 GHz

Note: for all the above listed outdoor units is available a correspondent indoor version: the ordering code is the same with /IN suffix.

transfer sub-carrier.

DMT/P

Output power 5W 25 W

RPT 4/1 RPT 4/4 RPT 4/8

HMR/P receiving units HMR/P 2 receiver and IF down-converter HMR/P 4 receiver and IF down-converter HMR/P 5-15 front-end and IF down converter HMR/P 24 front-end and IF down-converter

converter (HMR/P/70) to 70 MHz IF, and a transmitting up-converter (HMT/P/70) from 70 MHz IF to the output

RPT repeaters RPT 2/5 RPT 2/25

HMT/P 4/1 IF up-converter and transmitter HMT/P 4/4 IF up-converter and transmitter HMT/P 4/8 IF up-converter and transmitter

HMT/P 24/01 IF up-converter and transmitter HMT/P 24/03 IF up-converter and transmitter HMT/P 24/1 IF up-converter and transmitter

modulators and demodulators (MMT/P and DMT/P) with low power standard coaxial cables.

noise PLL oscillator.

HMT/P transmitting units HMT/P 2/5 IF up-converter and transmitter HMT/P 2/25 IF up-converter and transmitter

(5 Hz ÷ 9.1 MHZ) within 1 dB (5 Hz ÷ 5 MHz) within 0.5 dB (5 Hz ÷ 5 MHz) within 20 ns ≤2% ≤ 2° ≥ 62 dB (30 Hz ÷15 kHz) within 0.5 dB ≤ 0.1 % ≥ 68 dB

DB-13 TV Microwave Portable Analog Links-MLP-series  

for FM &amp; TV for FM &amp; TV RF input level -35 ÷ 80 dBm (50Ω) lst IF frequency 1000 ÷ 1400 MHz 2nd IF frequency 70 MHz IF output level -...