Page 1

Models: ACM - 52301 - J

Leaf Area Meter

TECHNOCRACY PVT. LTD.


Models: • ACM - 52301 - J

Leaf Area Meter


Weiber leaf area meter is compact, accurate tabletop instrument to check area of leaf. The operation is very easy, even a layman can operate. This instrument can also be used to check area of non-transparent flat surface material like cloth/paper/plastics/leather etc. This instrument is based on photometric technology.

Leaf Area Meter

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


Leaf Area Meter


RS 232 C interface Power Requirement: 230V, 50Hz., one CVT more than 100 VA capacity. Price: The cost of one single standard unit with all standard accessories. : HOW TO USE 1.1 Switching: press the "power" key, LCD display "Leaf Area Meter-B"'; Press the "Power" key again to shutdown. 1.2 Functional options: press the "function" key to scan the menu, then press the "confirm" key to operate. Function is as follows

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


Leaf Area Meter

LCD display

Function

M1: Measure

Measure the leaf area

M2: Record

Show records

M3: Delete

Delete records

M4: Width

M easure the leaf width

M5: Length

Measure the leaf width

M6: Send

Send data

M7: Other

Reserve


1.3 Measure the leaf area: Press the "function" key and choose the "M1" function, then press the "confirm" key to enter into the ready condition. Then LCD will display. Wait

100

A

=0

Put the leaf into the meter, place the leaf below the pressure lever, the initial position shouldn't cover measuring window. Fixe the measuring rope to leafstalk. Press the "confirm" key again, then the LCD display:

Run

W000

L000

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


W000 shows the changes valued of width, L000 shows the value of length, if the initial length is not 0, can press " " key to clear. And then slowly pulled out the leaf, finally press the "V" to display the measurement results. Rel

001

A =

123456

001 shows the first measurement, A= 123456 means the area of this measurement, unit is mn2. Press the "V" key again and shows the average:

Rel M =

001 123456

Leaf Area Meter


If measure again, press "Confirm "key, the LCD will display: Run

W000 L000

W000 shows the changes value of width, L000 shows the value of length, if the initial length is not 0, can press " " key to clear. And then slowly pulled out the leaf, finally press the "V" to display the measurement results: Rel

002

A =

123450

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


A= 123450 means measuring areas. Unit is mm2. Press "V" key again, display two times average. (M means average) Rel

002

M =

123453

002 means two times measuring datas, the average data is 123453. Press the "V" key again, the screen display 123450. Press "Confirm" key, can test the same leaf for many times. If want totest the other leaf. Just press "Function" key, restart to test and calculate the average. Press "OK" key, reserve the data. LCD display: OK! RecN=006

Leaf Area Meter


RecN means recording number, reserve the final measuring data, average data and measure times into the memory, can store 200 groups of datas. Note: After pulling out the measuring rope, shouldn't release the rope in a flash, should pulling back slowly, otherwise will damage the rope. 1.4 Show the records: Press the "function" key, choose the "M2" function, then press the " confirm " , LCD display: R001/006 A= 123456

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


001 means the current recording number, 006 means the total records in the memory. A= 123456 means the measuring area for 001. Press the "V" key to shows the average:

N= 002 M = 123456

N means the leaf is tested two times. The average M= 123456. Press thee "V" and " " key to scan other records. 1.5 Delete the records: Press the "function" key, choose the "M3" function, then press the "confirm" LCD display "Are your sure? " Press "confirm" key, could clear all the records in the Note: The function will clear all the records in the memory.

Leaf Area Meter

memory.

key.


Width W= 70mm

1.6 key, LCD display: W means the width is 70mm 1.7 Measure length: press the "function" key, choose the "M5" function, then press the "confirm", LCD display: Length L = 0mm

Pulling out measuring ropes to one side of the leaf. Press " " key to clear the data. Then pulling out measuring ropes to the other side of the leaf. The LCD will display the leaf length. Note: Length and wide th can't be reserved.

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


2.

Software

2.1 Properly connected to line of communication, run computer communications software. Communication is used default setting.

Baud rate: 4800

Parity bit: None

1, not choose "hex", "stop", "Clear" and

Data bit: 8, stop bit

"line-by-line display". Should set com number according to serial port. 2.2 Press "function" key, choose "M6" function, then press "confirm" key to send datas. 2.3 The window will display the received datas, Click "Reserve the datas" , the data (.TXT) will be reserved into file folder. Before receiving next time, click "clear receiving� 2.4 Data formats: 001 014586

011964 05

001 is recording number, 014586 is the final area data, unit is mm2, 011964 means average data is 011964, 05 is measuring times.

Leaf Area Meter


2.5 In the software data area, user can edit the data and text, add remarks. 3.

Specification

Test unit

:

Millimeter, square millimeter

Precision

:

+2%

Length

:

< 1000mm

Width

:

< 160mm

Thickness

:

< 8mm

Stored data :

200Groups

Serial Port Terminal: 1.

What is 'Free Serial Port Terminal' ?

Free serial port terminal is a serial communication application that is used to receive data from and send data to a device through serial communication port.

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


The program can be run under Win98/Win2000/WinXP/WinVista. It is not guaranteed to be run under Win7. If you need Unix-like(Linux) version, please contact us or visit our website for more support. 2.

Where can I find a serial communication port on my computer?

It is quite easy to find a 9-pin port at the back of desktop case. Though laptop computer may not have such a port, a usb-serial transfer module can do the job for you. How to get a usb-serial transfer module, please contact us or visit our website for more information.

Leaf Area Meter


3.

How to receive data from the devices? Follow the steps below:

a). Launch the Free Serial Port Terminal. Then, click settings->COM port settings, you'll get a setting dialog as below:

You may only need to change the value of Bit per second, please look up user manual of the device for details about serial com port settings.

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


b). Click the 'Open' button. The computer would be ready to receive data.

c). Click the "Send" button of the device to send data to computer. Generally, the data would display immediately on the screen. If not, please try again. If you can't get any data from the device after several attempts, please contact us for more information.

Leaf Area Meter


4. How to save the received data appeared in the screen to a file? If you want to save the received data to a file, please click: Log->Start logging. And a dialog would popup for a file that the data would be saved to. After you input a valid file name, then the data received would be reallocated to the file just chosen. If you needn't the time stamp, click the right key of mouse, chose Columns, deselect the Time Stamp. Next time, the program would not display any time stamps and you would get plain data.

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


TECHNOLOGY with


We are having Representatives in 55 Countries please visit our International Dealers Section to contact your nearest ACMAS Representative

h HUMAN TOUCH TECHNOCRACY PVT. LTD.


Leaf Area Meter

An ISO 9001:2208 | ISO 14001:2008 | ISO 13485 WHO:GMP Products | GLP Compliant Products

www.acmasindia.com | www.scientificlaboratoryequipments.com | www.measuring-meters.com TECHNOCRACY PVT. LTD. SALES OFFICE (INDIA) 312-313, Vardhman Capital Mall, L.S.C. 10, GulabiBagh, Delhi-110052, INDIA Tel: 0091-11-23646703, 23643054 (M) +91-9313971681| Email: india@acmasindia.com SALES OFFICE (HONG KONG) Unit D 28 11/f Wing Tat Comm, Bldg 97, Bonham Strand East, Sheung Wan, HONG KONG (PRC). Tel: 0086-13929598046 | 0086-18922303099 Email: hk@acmasindia.com SHOWROOM 141, Rai Industrial Estate, Rai, Sonepat, Haryana-131029, INDIA Tel: 0091-0-9312219738 (M) +91-9717741167 Email: info@acmasindia.com SALES OFFICE (RUSSIA) Inmed Trade Street, Ozerkovsky Embankment, Unit No 50 Straine-1, Off-502, Moscow, RUSSIA Tel: 0049-79592345 | Email: russia@acmasindia.com

leaf-erea-meter  

ACM - 52301 - J Models: TECHNOCRACY PVT. LTD. Leaf Area Meter Models: • ACM - 52301 - J Weiber leaf area meter is compact, accurate tabletop...