Bleeding Air from Fuel System (Diesel Engine Models) 1 DZ.2Z engine 1.

Operate the fuel filter hand pump until the pump operation becomes heavy to indicate the end of air bleeding.

Point Operations [Point 1I Removal.lnstallation:

Remove the air cleaner inlet side connector as follows.

1.

Disconnect the connector on the air cleaner case side. (1) Hold the connector elbow portion with a hand, and. pull downward until the connector side protrusion comes off from the groove on the case side.

2.

Disconnect the head guard pillar side connector. (1) Rotate the connector upward as illustrated and disconnect at the position where the pillar side notch aligns with the connector flange protruded portion.

3.

Reverse the removal procedure for installation.

[Point 21 Installation:

Do not mistake the fuel hose connecting position. (Gasoline engine models)

[Point 31 Removal:

Wrap each of the disconnected rod and the freed shift lever with tape for holding in place.