Page 33

Tools and work instructions

Service Manual

Special tools

1.2

Hydraulic system

Description Vacuum pump cpl. with accessory Consisting of: Vacuum pump with electrical cable Hose fitting Hose fitting Fitting S8M Fitting L6R PVC hose Terminal clamp, positive Terminal clamp, negative Plug 2-pin Temperature gauge

Id. No. 7408148

M-Type

Remarks

PR Series 4 LR Series 4 RL Series 4

For faster bleeding of hydraulic system, by enclosing the PVC hose, a slight excess pressure (ca.0.4 bar) can be produced. Connection point for the vacuum pump on the machine is the breather screw on the hydraulic tank

PR Series 4 LR Series 4 RL Series 4

Accuracy: 2% / 2°

7407987 7407985 10301165 7404619 4901110 7360127 10038447 10038448 7408151 10024185

Illustration

Difference pressure – Mess-Set 230V/120V

10288229

Consisting of: Test unit Multi-Handy 2045 2 Pressure sensors 0600 bar 2 Mini test connections 2 Test cable 12m long KFZ Connector cable Data cable Power unit Scale pressure gauge 0-10 0-25 0-40 0-60 0-100 0-160 0-250 0-400 0-600 0-1000

5002865 7361289 7361288 5002867 5602903 7361286 7361285 7500002 7361294 4601115

PR Series 4 LR Series 4 RL Series 4

To measure pressure, pressure peaks and pressure difference and suitable for data transfer to PC

PR Series 4 LR Series 4 RL Series 4

Accuracy: 1% of the scale end value All pressure gauges are „glycerin filled“

copyright by

2.1.00 - 4 / 22

Mjfcifss!

PR Litronic Series 4 LR Litronic Series 4 RL Litronic Series 4

LWT / Ausgabe / Edition / Edition / 03.2010

Test range: -18°C to +260°C

Liebherr rl44 pipe layer series 4 litronic service repair manual  
Liebherr rl44 pipe layer series 4 litronic service repair manual  