SERVICE STANDARDS Specific gravity in fully charged state

(OC) [OF1

1.280 (20) [681

Specific gravity in fully discharged state

(OC) [OF]

1.150 (20) I681

Discharge end voltage V

3 6 V specification

32.0

4 8 V specification

42.5 Sulfuric acid diluted with distilled water

Electrolyte

Distilled (deionized) Water

Fluid t o be spplied Insulation resistance

Mfl

I or more

DISPLAY INDICATION 1.

The display indicates the remaining battery charge level in 1 0 stages. When the remaining charge drops to the set level or below, the indication flashes the warn the timing for charging.

2. When the battery is discharged fully (100 %), the overdischarge alarm function operates as follows:

OVERDISCHARGE ALARM FUNCTION 1.

Material handling with traveling becomes impossible. If simultaneous operation is attempted, priority is given to traveling and material handling is not effected. (For prevention of battery from damage by large current flow)

2. When material handling is attempted, all indicators on the display flash and the buzzer sounds to alarm overdischarge. Note: Material handling operation becomes impossible on the vehicle with chopperless material handling circuit. For thirty seconds after the key switch is turned on, however, material handling operation can be performed.