Page 41

ELECTRICAL SYSTEM

Thermoswitch (T/C oil) Apply an ohmmeter between the terminal and body and check for continuity (resistance value). Replace the thermoswitch if the measured insulation resistance value is not more than the value listed in the table below.

Terminal

Body

1 M ohm or more (with contact OFF) (at 500 V megger)

Insulation resistance value

Internal resistance: 0.5 ohm or less (with contact ON) Allowable load: 0.5 A

NOTE When installing the thermoswitch, tighten it to the specified torque.

31.4 to 47.1 N·m (3.2 to 4.8 kgf·m) [23.2 to 34.7 lbf·ft]

Tightening torque

!

CAUTION

Replace the thermoswitch if it was dropped or abused.

Main specifications OFF→ON

122 ± 3 °C (251.6 ± 5.4 °F)

ON→OFF

115 °C (239 °F) or higher

Operating temperature

Insulation resistance (with contact OFF)

1 M ohm or more

3-11