Page 54

Door Assemblies

0100 YRM 1290

Door Cover With Air Conditioner and Heater Unit

2. Connect gas spring and lock nut to mounting bracket on operator cab frame. See Figure 38.

NOTE: The procedures in this section install air conditioner/heater unit assembly door cover onto right side door. For procedures to install or replace other components of air conditioner/heater unit assembly, go to Heater and Air Conditioner Assembly section.

3. Connect heater hoses to heater assembly and connect heater wire harness connection. See Figure 33 and Figure 34.

1. Install pre-filter on bottom of door frame. See Figure 41. 2. Align holes on door cover with holes that are on door frame. Install five plugs into holes that are along sides and front of door cover. Secure bottom of door cover using two capscrews and washers. 3. Install AC rocker switch plate to door cover using four capscrews. 4. Install two fasteners into holes on top of door cover. See Figure 41. 5. Install knob plate on heater valve and switch plate with four screws. Install fan and AC/heater knobs on knob plate. 6. Install hose wrap around AC hoses. See Figure 35 for lift truck models •

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (G813)

See Figure 36 for lift truck models •

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (H813)

See Figure 37 for lift truck models •

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (J813)

7. Install handle and handle plates on door with four screws and washers.

Install 1. Install right side door onto cab by lifting door over top and bottom hinge pins. See Figure 39.

48

4. On lift truck models GLP/GDP40VX5/VX6; GLP/ GDP45SVX5, GLP/GDP45VX6; GLP/ GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (G813, H813, J813) with a Cummins QSB 3.3L or Kubota diesel engine and equipped with an air conditioner/heater unit.

WARNING Replacement, installation and repairs to air conditioning units that require discharging and/or refilling of the refrigerant fluid must be performed by a certified technician. 5. Contact a certified air conditioning specialist to have the refrigerant refilled into the air conditioning system. a. Connect AC hoses at bulkhead bracket and to receiver/drier. See Figure 35 for lift truck models •

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (G813)

See Figure 36 for lift truck models •

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (H813)

See Figure 37 for lift truck models •

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (J813)

b. Install rear cover with six fasteners. See Figure 35 for lift truck models •

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (G813)

YALE H813 GLP50VX LIFT TRUCK (EUROPE) Service Repair Manual  
YALE H813 GLP50VX LIFT TRUCK (EUROPE) Service Repair Manual  