Caterpillar cat gp40k forklift lift trucks chassis and mast service repair manual sn:et29b 00011 and

Page 53

ELECTRICAL SYSTEM 1. Setting switches

The controller has a total of 16 setting switches.

NOTE Use a screwdriver to move each switch. The switch is made of resin; be careful not to damage the switch head in setting. 205001

(1) Switch setting pattern (Black dot indicates switch head.)

Setting window

Transmission speed Switch SW 2–2 Spear Switch SW 2–3

Normal OFF

Check ON

1200 bps OFF Normal OFF

Truck model Switch SW 3–1 SW 3–2

9600 bps ON

With OFF

Without ON

Oil pressure sensor Switch SW 2–5

Without OFF

(With) ON

OFF

Seat switch Switch SW 2–4

Spear Switch SW 2–6

Normal OFF

40K OFF OFF

40KL OFF OFF

45K OFF OFF

50K OFF OFF

– ON

– ON

WDT operation Normal mode WDT disabled Switch SW 2–7 OFF ON

1 2 3 4 5 6 7 8

OFF

Mode Switch SW 2–1

1 2 3 4 5 6 7 8

SW2

SW3

OFF

ON

No. of spools Switch SW 3–3 SW 3–4

3V ON OFF

4V OFF ON

– ON ON

Mast model Standard Simplex Duplex SW 3–5 Switch OFF OFF OFF SW 3–6 OFF OFF OFF

Spear Switch SW 3–7 Spear Switch SW 3–8

Program mode User program Boot mode Switch SW 2–8 OFF ON

2V OFF OFF

Normal OFF Normal OFF

Triplex OFF OFF

– ON – ON

208786

(2) Example of setting Truck:

GP40K

40 K

No. of spools: 3V Mast:

4V40A (simplex)

Option:

Speedometer with indicator light

3V

Seat switch

Standard

SW2

SW3 208787

3-27