Caterpillar cat gp18n forklift lift trucks service repair manual snt25c 70001 and up

Page 49

ELECTRICAL SYSTEM

Battery Drive belt slipping

Readjust.

❋ Alternator Stator coil grounded or open-circuited

Repair or replace.

Rotor coil open

Replace.

Brushes poorly seating on slip rings

Replace brushes if worn. Clean holder and polish slip rings.

Diode ruptured

Replace.

❋ Regulator Tends to run down rapidly

Regulated voltage setting too low

Replace.

❋ Battery Not enough electrolyte or wrong concentration of acid to water

Refill and check specific gravity.

Battery cell plates deteriorated (forming, possibly internal short-circuit)

Replace.

Terminal connections loose

Clean and retighten.

❋ Wiring Open or loose connection between starter switch and regulator IC terminal

Repair.

Fuse blown, or loosely set in holder

Replace and repair.

Open or loose connection between F terminals of regulator and alternator

Repair.

❋ Wiring

Tends to get overcharged

Regulator IC and F terminals shorted or miswired

Repair.

Poor grounding of regulator F terminal

Repair.

❋ Regulator Pressure coil open-circuited

Replace.

Regulated voltage too high

Replace.

3-23


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.