HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM

PRIMARY HYDRAULIC POWER SYSTEM - Exploded view 580N Pilot Machines only

RCPH10TLB006GAM

1. Cap for test port "M" (11/16-16 ORFS) 2. Pilot manifold test port 3. Swing Dampening Valve

1

4. Control module

7. Load sense relief valve

5. Gas strut for Pilot Control Adjustment 8. Regulated LS Drain 6. Regulated Manifold

NOTE: Connect a gauge capable of 344.8 bar (5000 psi) to "M" port (1) using adapter (PN 190119A1). Connect a gauge capable of 69.0 bar (1000 psi) to the pilot manifold pressure test port (2).

84516378 05/07/2011

A.10.A / 17