Page 35

ELECTRIC SYSTEM

2.2.5 Stop lamp switch Apply an ohmmeter across the terminals and check that the stop lamp switch is turned ON and OFF when the push rod protrusion is at the specified value.

Push rod

Measure the insulation resistance value across the terminals when the push rod is pushed in. Replace the stop lamp switch if its measured insulation resistance value is less than the value below. Insulation resistance value

2 mm (0.08 in.)

4 mm (0.16 in.)

1 M Ω or more (at 500 V megger)

M10×1.25

OFF

ON 215363

Rated voltage: DC12V 2.2.6 Thermoswitch (Engine cooling water temperature) (1) Apply an ohmmeter between the terminal and body of the sending unit and check for continuity (resistance value).

Body

Terminal

(2) Replace the sending unit if there is no continuity or the resistance value measured is outside the standard resistance value. Note: The illustration is for gasoline models.

215364

Gasoline model Temperature [°C (°F)]

60 ± 0.2 (140 ± 32.36)

65 ± 0.2 (149 ± 32.36)

80 ± 0.2 (176 ± 32.36)

100 ± 0.3 (210 ± 32.54)

125 ± 0.3 (257 ± 32.54)

130 ± 0.3 (266 ± 32.54)

80 ± 10

67 ± 7.8

40.6 ± 3.7

22.2 ± 1.4

11.3 ± 0.4

10 ± 0.3

Temperature [°C (°F)]

50 (122)

60 ± 0.2 (140 ± 32.36)

80 (176)

100 (212)

106 ± 0.3 (222.8 ± 32.54)

120 (248)

Standard resistance value (Ω)

(80)

56.3 ± 5

(29.5)

(16.5)

14.3 ± 0.5

(10)

Standard resistance value (Ω)

Diesel model

3-10