ELECTRIC SYSTEM

2.2.3 Horn Check that the horn activates when applying the specified voltage to both terminals of the horn, T1 and T2. Replace the horn if it does not activate or its sound is unusual.

Up

Operating voltage: DC12V (Gasoline and diesel models)

T1

Note: The proper installation of the horn to the lift truck is shown in the illustration. T2 Down Vent hole T1

Contact Coil

T2

215361

2.2.4 Tank unit

3/4

424.2 mm (16.7 in.)

F 242.7 mm (9.56 in.)

61.2 mm (2.41 in.)

Illustration shows gasoline model.

1/2

Pressure relief valve 1/4

Fuel pump Fuel filter

E

Fuel suction strainer

Referential Standards Float position

E

1/4

1/2

3/4

F

Standard resistance value (Ω)

80

(49.5)

32

(19)

10

Tolerance (Ω)

+12 +2

±3

+1.0 - 0.5

The number in parenthesis is a reference value.