XTRA•GUARD® 3

DIRECT BURIAL RoHS COMPLIANT 300 VOLT

MULTICONDUCTOR, UNSHIELDED

EXTRA-DURABLE OUTDOOR DIRECT-BURIAL JACKET

CHOOSE XTRA•GUARD 3 FOR: ■

Five Times the Water Resistance of PVC Cable Direct Burial in Wet Earth Without Conduit ■ Unsurpassed Service Life in Outdoor Use ■ Unmatched Ultraviolet Light Stability ■

XTRA•GUARD 3 APPLICATIONS: ■

56

Inter-building Communications ■ Satellite Communications Equipment ■ Land Irrigation Systems ■ Outdoor Security Systems ■ Outdoor Scoreboards and Displays ■ Pipeline Sensor Controls

CHARACTERISTICS OPERATING TEMPERATURE: ■ –20°C to 80°C VOLTAGE RATING: ■ 300 Volt COLOR DESCRIPTION: ■ Color Code: 22 AWG Chart E Page 375, ■ 20, 18, 16 AWG Chart D Page 375 ■ Jacket Color: Black PRODUCT DESCRIPTION: ■ Conductor: Stranded Tinned Copper ■ Insulation: Color-Coded Premium PVC ■ Nylon Rip Cord for Ease of Jacket Stripping ■ Jacket: Ethylene-Propylene Copolymer

AVAILABILITY

▲ In Stock: Black, 500 ■ ■

ft (152m) and 1000 ft

22 AWG (0,35mm2), 7/30 (7x0,25mm), Insulation Thickness: 0.010" (0,25mm) XTRA•GUARD 3 Part No. ▲ 35002 ▲ 35003 ▲ 35004 ▲ 35006 ▲ 35008 ▲ 35010 ▲ 35010/15

No. of Cond. 2 3 4 6 8 10 15

Jacket Thickness Inches mm 0.032 0.032 0.032 0.032 0.032 0.032 0.032

0,81 0,81 0,81 0,81 0,81 0,81 0,81

Nominal Diameter Inches mm 0.17 0.19 0.20 0.23 0.25 0.27 0.31

4,3 4,8 5,2 5,8 6,4 6,9 7,9

20 AWG (0,56mm2), 7/28 (7x0,32mm), Insulation Thickness: 0.017" (0,43mm) XTRA•GUARD 3 Part No. ▲ 35052 ▲ 35053 ▲ 35054 ▲ 35056 ▲ 35058 ▲ 35060 ▲ 35060/15

No. of Cond. 2 3 4 6 8 10 15

Jacket Thickness Inches mm 0.032 0.032 0.032 0.032 0.032 0.032 0.032

0,81 0,81 0,81 0,81 0,81 0,81 0,81

Nominal Diameter Inches mm 0.21 0.23 0.25 0.29 0.32 0.35 0.40

5,3 5,9 6,5 7,4 8,2 8,8 10,3

18 AWG (0,81mm2), 16/30 (16x0,25mm), Insulation Thickness: 0.017" (0,43mm) XTRA•GUARD 3 Part No. ▲ 35062 ▲ 35063 ▲ 35064 ▲ 35066 ▲ 35068 ▲ 35070 ▲ 35070/15

No. of Cond. 2 3 4 6 8 10 15

Jacket Thickness Inches mm 0.032 0.032 0.032 0.032 0.032 0.032 0.032

0,81 0,81 0,81 0,81 0,81 0,81 0,81

Nominal Diameter Inches mm 0.23 0.24 0.26 0.31 0.33 0.39 0.45

5,8 6,1 6,6 7,9 8,4 9,8 11,5

(305m) put-ups

Made-To-Order Only, 1,000 ft (305m) minimum

16 AWG (1,23mm2), 19/0.0117 (19x0,29mm), Insulation Thickness: 0.017" (0,43mm) XTRA•GUARD 3 Part No. ▲ 35072 ▲ 35073 ▲ 35074 ▲ 35076 ▲ 35078 ▲ 35080 ▲ 35080/15

No. of Cond. 2 3 4 6 8 10 15

Jacket Thickness Inches mm 0.032 0.032 0.032 0.032 0.032 0.032 0.032

0,81 0,81 0,81 0,81 0,81 0,81 0,81

Nominal Diameter Inches mm 0.26 0.29 0.32 0.37 0.41 0.44 0.52

6,5 7,4 8,1 9,3 10,4 11,3 13,2