DAIKIN General Catalogue 2012

Page 191

Heating & Cooling Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz

Outdoor unit module 1 Nom. Nom. Cooling Heating

Nom. Nom.

EER COP APF Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit System

mm kg dBA dBA 째CDB 째CWB mm mm m m m Hz/V A

HP kW kW kW kW

dBA dBA mm mm m m m Hz/V A

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP APF Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

RXYQ10P9 RXYQ12P9 RXYQ10P9 RXYQ12P9 10 12 28.0 33.5 31.5 37.5 7.42 9.62 7.70 9.44 3.77 3.48 4.09 3.97 5 21 26 1,680x930x765 240

187

RXYQ14P9 RXYQ14P9 14 40.0 45.0 12.4 11.30 3.23 3.98 4.6 30

78 57

RXYQ16P9 RXYQ16P9 16 45.0 50.0 14.2 12.90 3.17 3.88 4.4 34 1,680x1,240x765 316

80 60

58

9.52 19.1

15.9

12.7 22.2

RXYQ18P9 RXYQ18P9 18 49.0 56.5 16.2 15.30 3.02 3.69 4.2 39 324 83 63

20 55.90 62.50 14.71 14.95 3.80 4.18 4.9 43

RXYQ22P9 RXYQ10P9 RXYQ12P9 22 61.50 69.00 16.99 17.08 3.62 4.04 4.8 47 83

62

RXYQ24P9 RXYQ12P9

RXYQ26P9 RXYQ8P9

RXYQ28P9 RXYQ10P9

24 67.00 75.00 19.20 18.89 3.49 3.97

26 71.40 81.50 20.94 20.69 3.41 3.94

28 77.00 88.00 23.62 22.98 3.26 3.83 4.5 60

4.6 52

56

63

RXYQ30P9 RXYQ32P9 RXYQ12P9 RXYQ14P9 RXYQ18P9 30 32 82.50 89.00 94.00 102.00 25.78 28.62 24.67 26.63 3.20 3.11 3.81 3.83 4.4

RXYQ34P9 RXYQ16P9

RXYQ36P9 RXYQ18P9

34 94.00 107.00 30.42 28.23 3.09 3.79 4.3

36 98.00 113.00 32.45 30.62 3.02 3.69 4.2

64

64

34.9 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 63

50

86 66

65 19.1

15.9

RXYQ40P9 RXYQ10P9 RXYQ12P9 40 111.00 126.00 33.23 32.39 3.34 3.89 4.5

40

85

28.6

38 105.00 119.00 30.61 30.13 3.43 3.95 4.6

15.9 28.6

165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 25

16

RXYQ38P9 RXYQ8P9

Outdoor unit module 1 Outdoor unit module 2

RXYQ8P9 RXYQ8P9 8 22.4 25.0 5.22 5.56 4.29 4.50 5.4 17

-5.0~43.0 -20~15 R-410A

RXYQ20P9 RXYQ8P9

Outdoor unit module 1 Outdoor unit module 2

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP APF Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit System

HP kW kW kW kW

RXYQ5P9 RXYQ5P9 5 14.0 16.0 3.52 4.00 3.98 4.00 5.0 10 1,680x635x765 159 72 54

RXYQ42P9 RXYQ12P9

RXYQ44P9 RXYQ8P9

RXYQ46P9 RXYQ10P9

42 116.00 132.00 35.37 34.20 3.28 3.86

44 120.00 138.00 36.92 35.94 3.25 3.84 4.4

46 126.00 145.00 39.75 38.26 3.17 3.79

RXYQ48P9 RXYQ50P9 RXYQ12P9 RXYQ14P9 RXYQ18P9 48 50 132.00 138.00 151.00 158.00 42.04 44.81 39.95 41.91 3.14 3.08 3.78 3.77 4.3

41.3

80 RXYQ52P9 RXYQ16P9

RXYQ54P9 RXYQ18P9

52 143.00 163.00 46.58 43.47 3.07 3.75

54 147.00 170.00 48.68 45.95 3.02 3.70 4.2

64 dBA dBA mm mm m m m Hz/V A

86 66

87 67 19.1 41.3 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 100

189

88 68

125