91772sl.pdf Reelmaster 335-D/3500-D (Rev C) 2002

Page 197

Cutting Unit Operation Problems (continued) Condition

Possible Cause

Correction

___________________________________________________________________________________________ No cutting units engage.

Reelmaster® 335-D

Axle in Hi range.

Axle must be in Low range for cutting units to operate.

“Reel” fuse open.

Check fuse and replace if fuse is open. If fuse burns out often, find and correct cause.

Cutting unit relay faulty.

Test relay. Replace relay if faulty.

Cutting unit relay wiring loose, corroded or damaged.

Repair wiring.

Transaxle shift linkage out of adjustment (not closing Hi/Low switch in Low range).

Check linkage and adjust if necessary.

Axle Hi/Low switch faulty.

Test switch. Replace if faulty. Make sure switch is screwed all the way in.

Axle Hi/Low switch wiring loose, corroded or damaged.

Repair wiring.

PTO switch faulty.

Test switch. Replace if faulty.

PTO switch wiring loose, corroded or damaged.

Repair wiring.

Variable reel control in neutral (N) position or linkage out of adjustment..

Check control and linkage. Adjust linkage if necessary.

Variable reel control switch faulty.

Test switch. Replace if faulty. Make sure switch is screwed all the way in.

Variable reel control switch wiring loose, corroded or damaged.

Repair wiring.

Problem not electrical.

See Troubleshooting section in Chapter 4 - Hydraulic System.