Vetus Catalog (Partial)

Page 72

ELECTRICITY ON BOARD COMBI-GAMMA

The VETUS Combi-γ may be used: • As an inverter (from 12 or 24 Volt D.C. to 230 Volt A.C.) • As a battery charger • In combination with the VETUS solar charger The description of the inverter function is identical to the VETUS sine wave inverters shown on page 162. The battery charger has a four-stage function: boost, absorption, float and equalize. Two batteries or battery banks may be connected to it. In combination with a VETUS solar charger, the Combi-γ unit can exchange data and control the current supply, as well as the charging characteristics.

COMBI In addition to its major functions, the Combi-γ has many more features: • Power Control With the incorporated Power Control, the maximum input current from the shore supply or the generator set can be selected. This ensures that the circuit breaker on the shore supply or generator will not trip. • Power Manager The Power Manager function controls and regulates the entire power supply. If you need more power, the Power Manager will automatically switch in the inverter, or start the generator, in order to supply the required power.

Vetus “Combi-γ”, model

COMBI1512

One 3 kW Combi-γ unit will therefore supply a total of 6kW (3kW via the inverter function and a further 3 kW from the shore supply or the generator). • UPS (Uninterrupted Power Supply) If the power supply from the shore supply or generator fails, the Combi-γ inverter function will switch in automatically. • Parallel connection To achieve the maximum required power levels, up to 5 Combi-γ units can be connected in parallel. • Three-phase functionality A three-phase supply system may also be created with 3 Combi-γ units. Using 3 kW Combi-γ’s in parallel and three-phase, a total output of 45 kW can be achieved.

REMOTE CONTROL PANEL FOR COMBI-γ A remote control panel may be connected to the Combi-γ unit. This panel displays the following information: • AC input and output voltage and current • Battery voltage, current and power consumption • Charging voltage and charging current levels of Combi-γ and solar charger • UPS status • Multifunctional relay status • Alarms

GAMPANEL

IT ALSO CONTROLS:

• Inverter, battery charger, solar charger ON/OFF • Switching levels • Charge voltage and current • Relays • Parallel 3-phase configuration • AC output voltage and frequency

COMBI3012

COMBI1524

COMBI3024

input

Inverter: Nominal battery voltage

10-16V

Max. input current at 10.5V resp. 21V and Pnom

20-32V

167 A

334 A

Voltage Frequency

167 A

Adjustable: 50 of 60Hz ± 0.1%

Wave shape output

84 A Adjustable: 185-240V AC

Pure sine, total harmonic distortion < 3%

Nominal power

Continuous at cos phi = 1, at a max. inverter temperature of 75° C 1500W

Peak power

3000W

1500W

3000W

60 min

30 min.

10 min.

5 sec.

1 sec.

105 - 110%

120 - 130%

140 - 145%

150%

200%

Cos phi (power factor)

All types of load are permitted

output

input

Battery charger: Voltage

200-250V AC

Frequency

45-55Hz or 55-65Hz

Cos phi (power factor)

1

Charging Current

Adjustable

Maximum charging current

70A

120A

Charging current starter battery

40A

70A

4A

General: Input power in UPS mode

180 -245, switch-over time < 3 msec.

Max. switching current UPS

16A

30A

16A

30A

Max. current Power Control

10A

20A

10A

20A

Multifunctional relay

3x

Ambient temperature

During storage: -30ºC to + 70ºC. During use: 0ºC to + 50ºC (inverter temp. 75°C)

Relative humidity

Max. 95%, condensation-free (all printed circuit boards are coated)

Protection class

IP20

Solar Charger, type

SL45

SL60

Maximum charging current

45A

60A

Charging characteristics

4-stage

Battery voltage

12-48V

Maximum voltage of solar panel Minimum voltage of solar panel Ambient temperature Relative humidity Dimensions (H x W x D) in mm Weight

125V 9V During storage: - 55º C to + 85º C During use: - 40° C to + 45° C Max. 95%, condensation-free (p.c.b. is coated) 266 x 127 x 75 1,5 kg

SOLAR CHARGER

The VETUS Solar Charger enables regulated battery charging when using solar panels. In addition to its charging function this unit ensures that, when the batteries are fully charged, the output of the solar panels can be used for other purposes (diversion regulation). In order to prevent complete discharge of the battery, the charging control function will disconnect any consumers when the battery voltage drops too low. The VETUS Solar Charger may be used as a stand alone unit, or in combination with the VETUS Combi-γ unit. In this case the Combi-γ will control the complete current supply. Up to 10 Solar Chargers may be connected in parallel formation. The Solar Charger is protected against: 1. short circuit 2. current overload from solar panel 3. reversed battery polarity 4. excess temperature.

SL

164 www.vetus.com

164165_11_ROW.indd 2

12/16/2010 11:47:19 AM


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.