Full Line Pocket Catalog

Page 15

Residential Gas Energy Saver TTW® High EF Water Heaters

28/29 C

■ High Energy Factor (EF) – These models qualify for most energy rebate programs as well as the September 1, 2010 minimum ENERGY STAR® EF requirement ■ Bradford White ICON System™ ■ Advanced ScreenLok® Technology Flame Arrestor Design ■ Flammable vapor sensor ■ Powerful blower motor ■ Horizontal and vertical venting

■ Vitraglas® Lining ■ Factory installed Hydrojet® Total Performance System ■ Water Connections 3/4" NPT factory installed true dielectric fittings ■ Pedestal base ■ 2" Non-CFC foam insulation ■ Protective magnesium anode rod ■ Factory installed heat traps ■ T&P relief valve included ■ Low restriction brass drain valve

A

B G

F D

H E Photo of M-4-TW-40T6FBN

Power Vent Energy Saver Models

Meet or exceed ASHRAE 90.1b (current standard) CEC Listed 78% Recovery Efficiency

DIMENSIONS IN INCHES

NATURAL GAS AND LIQUID PROPANE GAS MODELS Model Number

M-4-TW40T6FBN M-4-TW50T6FBN M-4-TW60T6FBN

Gal. Cap.

Input BTU/Hr.

40 50 60

40,000 40,000 40,000

A

GPH 1st Hour** Recovery Delivery 90°F Rise* Rating

72 86 98

43 43 43

Floor to Vent Conn.

67 67 68

C

D

E

F

G

H

Jacket Dia.

Vent Size

Floor to T&P Conn.

Floor to Gas Conn.

Floor to Top of Heater

Floor to Water Conn.

Depth

Approx. Shipping Weight (lbs)

20 22 24

2 2 2

50 50 501/2

113/4 113/4 113/4

563/4 57 573/4

573/4 58 583/4

247/8 263/4 283/4

152 175 210

B

*Based on manufacturers rated recovery efficiency. All propane models feature a Titanium Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”. For 10 year models, change suffix from “6” to “10”. 110 V.A.C. Required for Power Venting / 110 V.A.C., 60HZ, 3.1 Amperes. **First Hour Delivery Rating is based on the March 2010 AHRI Directory. M-4-TW-40 M-4-TW-50 M-4-TW-60 Max. Equivalent Length Min. Equivalent Length Number of 90° Elbows†

1 2 3

2" Vent Pipe

3" Vent Pipe

50 ft. 7 ft. 45 ft. 40 ft. 35 ft.

120 ft. 15 ft. 115 ft. 110 ft. 105 ft.

†Consult I&O manual when using four or more elbows. Subtract 5ft. for each additional 90° elbow.

(LP) Propane Gas Inputs

M-4-TW-40T6FSX M-4-TW-50T6FSX M-4-TW-60T6FSX

38,000 BTU/Hr. 38,000 BTU/Hr. 38,000 BTU/Hr.

GPH Rec. 90°F Rise

41 41 41


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.