Product Catalog LUMEL S.A. july 2012

Page 65

technical data Type

EB16

Measuring ranges: . direct - current: . through a transformer (on request with twice or six-times overload) - voltage:

Moving-iron meters EA16 EA17 EA19

. direct . through a transformer

100 mA ... 25 A xA x/5 A; xA/1 A

100 mA ... 100 A xA x/5 A; xA x/1A

6 V ... 600 V xV/100 V; xV/110 V

6 V ... 1000 V xV/ 100 V; xV/110 V

Frequency of measured value IP52/IP20

5...23...50 οC

Climate version

normal or tropical

normal, tropical or similar to marine

External dimensions [mm]

53 x 90

Panel cut-out [mm]

on a rail

45

x 45

Panel cut-out [mm] - for version with IP65

on a rail

47

x 47

48 x 48 +0.6 +0.6

+0.6 +0.6

MA17P

Measuring ranges (direct): - current: - voltage:

68

+0.7

96 x 96

x 68

+0.7

92

+0.8

144 x 144

x 92

138

+0.8

+1.0

70.2+0.7 x 70.2+0.7 94.2+0.8 x 94.2+0.8

x 138

EA12

+1.0

-

MA19P

MA12P

400 µA...1 A (30...1000... 10 000 Hz) 1 A...6 A (49...50...51 Hz)

400 µA...1 A (30...1000...10 000 Hz)

60 mV...1,5 V (49...50...51 Hz) 2,5 V...600 V (30...1000... 10 000 Hz)

2,5 V...600 V (30...1000...10 000 Hz)

IP50/IP20 (on request: IP65/IP20)

IP50/IP20 (on request: IP54/IP20)

Protection rating frontal/rear side Ambient temperature

5...23...55 οC

Climate version:

normal, tropical or similar to marine

External dimensions [mm] Panel cut-out [mm] Panel cut-out [mm] - for version with IP65

72 x 72 68+0.7 x 68+0.7

96 x 96 92+0.8 x 92+0.8

144 x 144 138+1.0 x 138+1.0

70.2+0.7 x 70.2+0.7

94.2+0.8 x 94.2+0.8

-

MA12

PA39

EP29

3-phase voltmeters EP27

EP29

Voltage measuring rangess: - direct phase-to-phase:

External dimensions [mm] Panel cut-out [mm]

72 x 72

Moving-coil meters with rectifiers

Type

Climate version

on request: IP54/IP20

on request: IP65/IP20

Ambient temperature

- through a transformer: Frequency of measured value Protection rating frontal/rear side

EB16

40...45..65...72 Hz IP50/IP20

Protection rating frontal/rear side

Type

EA12

Type

Power meters PA39

Power measuring ranges:

50W...1000 MW or 50 var...1000 Mvar

Frequency of measured value

500 V xV/100 V; xV/110 V 40...45...65...72 Hz

Protection rating frontal/rear side

50 Hz, 60 Hz or 400 Hz IP50/IP20 (on request: IP65/IP20)

Ambient temperature

5...23...40 οC

IP50/IP20 normal, tropical or similar to marine 72 x 72 68+0.7 x 68+0.7

96 x 96 +0.8 92 x 92+0.8

Climate version

normal, tropical or similar to marine

External dimensions [mm] Panel cut-out

96 x 96 94.2+0.6 x 94.2+0.6

WWW.LUMEL.COM.PL

65


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.