ANALOG METERS
Ordering codes A.C. AMMETERS AND
I VOLTMETERS
EV SERIES
TABLE 81. EV048, EV072, EV09, EV144
TABLICA 82 - ACCESSORIES: SCALE
EV048, EV072, EV096, EV144 - XXX XXX X XX Meters dimensions: 48 x 48 mm 048 72 x 72 mm 072 96 x 96 mm 096 144 x 144 mm 144 Measuring range: acc. to table 83 XXX Scale: without scale 0 scale equal to measuring range 1 Version: standard 00 custom-made XX Acceptance tests: without extra requirements with an extra quality inspection certificate
X
0 1
Measuring range
Meassuring range
Range code:
Meassuring range
001
75/150A 75/5A
009
500/1000A 500/5A
002
80/160A 80/5A
010
600/1200A 600/5A
003
100/200A 100/5A
011
750/1500A 750/5A
004
150/300A 150/5A
012
800/1600A 800/5A
005
200/400A 200/5A
013
1/2kA 1000/5A
006
250/500A 250/5A
014
4/8kA 4000/5A
007
300/600A 300/5A
015
500V
008
400/800A 400/5A
EV072
EV096
EV144
75/150A 75/5A
0904-145-209
0904-145-009
0904-145-509
0904-145-709
80/160A 80/5A
0904-145-210
0904-145-010
0904-145-510
0904-145-710
100/200A 100/5A
0904-145-201
0904-145-001
0904-145-501
0904-145-701
150/300A 150/5A
0904-145-202
0904-145-002
0904-145-502
0904-145-702
200/400A 200/5A
0904-145-203
0904-145-003
0904-145-503
0904-145-703
250/500A 250/5A
0904-145-211
0904-145-011
0904-145-511
0904-145-711
300/600A 300/5A
0904-145-204
0904-145-004
0904-145-504
0904-145-704
400/800A 400/5A
0904-145-205
0904-145-005
0904-145-505
0904-145-705
500/1000A 500/5A
0904-145-212
0904-145-012
0904-145-512
0904-145-712
600/1200A 600/5A
0904-145-206
0904-145-006
0904-145-506
0904-145-706
750/1500A 750/5A
0904-145-213
0904-145-013
0904-145-513
0904-145-713
800/1600A 800/5A
0904-145-207
0904-145-007
0904-145-507
0904-145-707
1/2kA 1000/5A
0904-145-208
0904-145-008
0904-145-508
0904-145-708
4/8kA 4000/5A
0904-145-214
0904-145-014
0904-145-514
0904-145-714
TABLE 83 Range code:
Ordering codes for scale EV048
Additional accessories: - IP65 cover: for EV048 - code: 1301-130-702 for EV072 - code:1301-130-701 for EV096 - code: 1301-130-700
POWER METERS PA39 TABLE 85
TABLE 84. POWER METER PA39 PA39 - X Kind of measured power and measuring element: measurement of active power in 1-phase network measurement of active power in a 3-phase network, 3-wire balanced network measurement of active power in a 3-phase network, 3-wire unbalanced network measurement of active power in a 3-phase network, 4-wire balanced network measurement of active power in a 3-phase network, 4-wire unbalanced network measurement of reactive power in a 3-phase network, 3-wire balanced network measurement of reactive power in a 3-phase network, 3-wire unbalanced network measurement of reactive power in a 3-phase network, 4-wire balanced network measurement of reactive power in a 3-phase network, 4-wire balanced network Input voltage: write in the range code Un from the table 85 Frequency of the input voltage: 50 Hz 60 Hz 400 Hz Input current: write in the range code In from the table 85 Power flow direction: unidirectional, zero on the left side of the scale bidirectional, zero in the middle side of the scale Work position: write in the position code from the table 88 Version: standard custom-made Acceptance tests: without extra requirements with an extra quality inspection certificate other requirements
70
WWW.LUMEL.COM.PL
X
X
X
X
X
XX
X
A B C D E F G H K X 0 1 2 X 0 1 X 00 XX 0 1 X
Notes: the power range results from the given rated values of current and voltage transformers, acc. to the table 3 (e.g. for the given example, the power range is 1,5 Mvar).