Page 11-42 from Sealine Scheepskabels en

Page 17

Special cable

www.leoni-marine-technologies.com

PiMF-Control Cable M-2XCH Copper bare, 7 strands class 2 (IEC 60228) Insulation XLPE Screen alu-laminated foil Drainwire Tape Shield bare copper braid Outer jacket SHF1

Technical data Application Flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants. The cables meet the technical requirements of IEC 60092-351, IEC 60092-359, IEC 60092-376. Marking LEONI KERPEN * SeaLine * Size • Nom. diameter • 250 V • LSZH • Lengthmarking

Conductor resistance

≤ 26 Ω/km

Insulation resistance

≥5 GΩ· km

Operating voltage

250 V

Testing voltage (core/core)

1500 V

at rms 50 Hz 5 min

Testing voltage (core/shield)

1500 V

at rms 50 Hz 5 min

Mechanical properties Temperature range

during operation during installation

–40 °C to +90 °C –20 °C to +50 °C

Bending radius

during operation during installation

10 x D 5xD

Burning characteristics IEC 60332-1-2, IEC 60332-3-22, IEC 61034-2, IEC 60754-1 & -2

Cable construction and types Designation M-2XCH 2 x 2 x 0.75 M-2XCH 4 x 2 x 0.75 M-2XCH 7 x 2 x 0.75 M-2XCH 10 x 2 x 0.75 M-2XCH 14 x 2 x 0.75 M-2XCH 19 x 2 x 0.75 M-2XCH 24 x 2 x 0.75

PiMF PIMF PiMF PiMF PiMF PiMF PiMF

Core-Ø [mm]

Cable-Ø [mm]

Weight [kg/km]

nom.

nom.

nom.

2.1

11.6 13.6 16.6 20.2 22.4 25.8 28.6

160 240 370 530 640 860 1030

Colour code

numbers printed on blue wires

Reference 80820000 80820001 80820002 80820003 80820004 80820006 80820005

27