Special cable
www.leoni-marine-technologies.com
PiMF-Control Cable M-2XCH Copper bare, 7 strands class 2 (IEC 60228) Insulation XLPE Screen alu-laminated foil Drainwire Tape Shield bare copper braid Outer jacket SHF1
Technical data Application Flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants. The cables meet the technical requirements of IEC 60092-351, IEC 60092-359, IEC 60092-376. Marking LEONI KERPEN * SeaLine * Size • Nom. diameter • 250 V • LSZH • Lengthmarking
Conductor resistance
≤ 26 Ω/km
Insulation resistance
≥5 GΩ· km
Operating voltage
250 V
Testing voltage (core/core)
1500 V
at rms 50 Hz 5 min
Testing voltage (core/shield)
1500 V
at rms 50 Hz 5 min
Mechanical properties Temperature range
during operation during installation
–40 °C to +90 °C –20 °C to +50 °C
Bending radius
during operation during installation
10 x D 5xD
Burning characteristics IEC 60332-1-2, IEC 60332-3-22, IEC 61034-2, IEC 60754-1 & -2
Cable construction and types Designation M-2XCH 2 x 2 x 0.75 M-2XCH 4 x 2 x 0.75 M-2XCH 7 x 2 x 0.75 M-2XCH 10 x 2 x 0.75 M-2XCH 14 x 2 x 0.75 M-2XCH 19 x 2 x 0.75 M-2XCH 24 x 2 x 0.75
PiMF PIMF PiMF PiMF PiMF PiMF PiMF
Core-Ø [mm]
Cable-Ø [mm]
Weight [kg/km]
nom.
nom.
nom.
2.1
11.6 13.6 16.6 20.2 22.4 25.8 28.6
160 240 370 530 640 860 1030
Colour code
numbers printed on blue wires
Reference 80820000 80820001 80820002 80820003 80820004 80820006 80820005
27