Wall mounted unit Designed for colder climates

FTXS-J / RXL-J

FTXS20,25,35J

› › ›

› › › › › › › ›

RXL20,25,35J

ARC452A3

Optimised heating solution for your home Extended operation range down to -20°C in heating 2 area intelligent eye: air flow is sent to a zone other than where the person is located at that moment; if two people are detected in the room, the air flow is projected away from the occupants; if no people are detected, the unit will automatically switch over to the energy-efficient setting Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces ECONO mode decreases power consumption so that other appliances that need large power consumption can be used Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode Night set mode saves energy by preventing overcooling or overheating during night time Indoor unit silent operation: “silent” button on the remote control lowers the operation sound of the indoor unit by 3dBA Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Heating & Cooling Indoor unit Cooling capacity Heating capacity Power input

Min./Nom./Max. Min./Nom./Max. Cooling Nom. Heating Nom.

EER / COP Annual energy consumption Energy label Cooling/Heating Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit High/Nom./Low/Silent operation Fan - Air flow rate Cooling High/Nom./Low/Silent operation Heating Sound power level Cooling Nom. Heating Nom. High/Nom./Low/Silent operation Sound pressure Cooling level High/Nom./Low/Silent operation Heating Refrigerant Type Piping connections Liquid/Gas OD Power supply Phase / Frequency / Voltage Outdoor unit HeightxWidthxDepth Dimensions Unit Weight Unit Fan - Air flow rate Cooling High/Super low Heating High/Super low Sound power level Cooling Nom./High High/Silent operation Sound pressure Cooling level High/Silent operation Heating Operation range Cooling Ambient Min.~Max. Heating Ambient Min.~Max. Refrigerant Type Piping Level difference IU-OU Max. connections Total piping length System Actual Power supply Phase / Frequency / Voltage

kW kW kW kW kWh

mm kg m³/min m³/min dBA dBA dBA dBA

FTXS20J 1.3/2.0 /2.8 1.3/2.7 /4.3 0.45 0.61 4.44 / 4.43 225

FTXS25J 1.3/2.5 /3.2 1.3/3.3 /4.7 0.54 0.71 4.67 / 4.65 268 A/A White 295x800x215 9

9.4/7.4/5.5/4.1 9.9/8.2/6.6/6.2 54 54 38/32/25/22 38/33/28/25

10.8/7.9/5.2/3.7 11.9/9.1/6.4/5.9 57 58 41/33/25/22 42/35/28/25 R-410A 6.35 / 9.5 1~ / 50 / 220-240

RXL20J

RXL25J 550x765x285

mm Hz / V

mm kg m³/min m³/min dBA dBA dBA °CDB °CWB

FTXS35J 1.4/3.5 /4.0 1.4/4.0 /5.2 0.86 0.95 4.07 / 4.21 430

32 36.2/32.7 30.6/28.5

10 11.4/8.7/5.8/4.4 12.4/9.5/6.8/6.0 61 61 45/37/29/23 45/39/29/26

RXL35J 34

33.5/30.1

36.0/30.1 28.3/25.6

-/61 46/43 47/44

-/63 48/44 48/45 -10~46 -20~20 R-410A 15 1~ / 50 / 220-230-240

m m Hz / V

80