Energy efficient units: full range A class energy labels Remarkable blend of iconic design and engineering excellence with an elegant finish in brushed aluminium or matt crystal white Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode. Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Movement sensor saves power consumption in unoccupied rooms: when the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room. Indoor/outdoor unit silent operation: “silent” button on the remote control lowers the operation sound of the indoor/outdoor unit by 3dBA Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. The infrared remote control is user friendly and equipped with a timer function that enables you to programme the unit to start or stop at your desired time. Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen
Heating & Cooling Indoor unit Cooling capacity Heating capacity Power input
Min./Nom./Max. Min./Nom./Max. Cooling Min./Nom./Max. Heating Min./Nom./Max.
EER / COP SEER* Annual energy consumption Energy label Cooling/Heating Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit High/Nom./Low/Silent operation Fan - Air flow rate Cooling High/Nom./Low/Silent operation Heating Sound power level Cooling Nom. Heating Nom. High/Nom./Low/Silent operation Sound pressure Cooling level High/Nom./Low/Silent operation Heating Refrigerant Type Piping connections Liquid/Gas/Drain OD Power supply Phase / Frequency / Voltage Outdoor unit HeightxWidthxDepth Dimensions Unit Weight Unit Fan - Air flow rate Cooling High/Super low Heating High/Super low Sound power level Cooling Nom./High High/Silent operation Sound pressure Cooling level High/Silent operation Heating Operation range Cooling Ambient Min.~Max. Heating Ambient Min.~Max. Refrigerant Type Piping Level difference IU - OU Max. connections Total piping length System Actual Power supply Phase / Frequency / Voltage
kW kW kW kW
kWh
mm kg m³/min m³/min dBA dBA dBA dBA mm Hz / V
FTXG25JW 1.3/2.5/3.0 1.3/3.4/4.5 -/0.56/-/0.78/4.46 / 4.36
FTXG35JW 1.4/3.5/3.8 1.4/4.0/5.0 -/0.89/-/0.99/3.93 / 4.04 To be confirmed 280 445 A/A Matt crystal white 295x915x155 11 8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 54 58 55 58 38/32/25/22 42/34/26/23 39/34/28/25 42/36/29/26 R-410A 6.35 / 9.5 / 18.0 1~ / 50 / 220-240
FTXG50JW 1.7/5.0/5.3 1.7/5.8/6.5 0.450/1.560/1.880 0.520/1.600/2.500 3.21 / 3.63 780
10.3/8.5/6.7/5.7 11.4/9.8/8.1/7.1 60 60 44/40/35/32 44/40/35/32 6.35 / 12.7 / 18.0
RXG25K mm kg m³/min m³/min dBA dBA dBA °CDB °CWB
*FTXG25JA 1.3/2.5/3.0 1.3/3.4/4.5 -/0.56/-/0.78/4.46 / 4.36
*FTXG35JA 1.4/3.5/3.8 1.4/4.0/5.0 -/0.89/-/0.99/3.93 / 4.04 To be confirmed 280 445 A/A Brushed aluminium 295x915x155 11 8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 54 58 55 58 38/32/25/22 42/34/26/23 39/34/28/25 42/36/29/26 R-410A 6.35 / 9.5 / 18.0 1~ / 50 / 220-240
RXG35K
36.0/30.1 28.3/25.6
-/61 46/43 47/44
780
10.3/8.5/6.7/5.7 11.4/9.8/8.1/7.1 60 60 -/44/40/35/32 44/40/35/32 6.35 / 12.7 / 18.0
RXG50K 735x825x300 48 50.9/48.9 45/43.1
550x765x285 34 33.5/30.1
*FTXG50JA 1.7/5.0/5.3 1.7/5.8/6.5 0.450/1.560/1.880 0.520/1.600/2.500 3.21 / 3.63
-/63 48/44 48/45 -10~46 -15~20 R-410A
m m Hz / V
15
20 1~ / 50 / 220-240
*prEN14825 (inquiry version 2010)
*Note: grey cells contain preliminary data